LCA-2
1 /11Pages

LCA-2

LCA-2
1 /11Pages

Catalog excerpts

LCA-2-1

Extract from our online catalogue: LCA-2 Current to: 2025-01-27 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® is a registered trademark of microsonic GmbH. All rights reserved.

 Open the catalog to page 1
LCA-2-2

The LCA-2 facilitates the comfortable setting of numerous microsonic sensor series. > Three-digit digital display > for the display of measured distance values in mm or cm > TeachBox with four-button operation > for programming of the sensor without a PC > LinkCopy function > for copying the sensor settings from one sensor to another without a PC > Uniform microsonic teach-in for all microsonic sensors > to keep easy things easy > Handy adapter > for the programming of ultrasonic sensors > T plug > to insert the adapter between the connector cable and the sensor > LinkControl software > free...

 Open the catalog to page 2
LCA-2-3

Description The LinkControl adapter LCA-2 is equipped with a USB interface for connection to a PC or laptop. With the LinkControl software, the ultrasonic sensors of the mic+, mic, pico+, lpc+, cube , lcs+, lcs, ucs, pico+TF, crm+, hps+, pms, bks+, bks, dbk+, esp and esf series can be parameterised under Windows®. LinkControl software: input mask The current measurement values of the ultrasonic sensors can be graphically visualised in the LinkControl software in the form of three different output graphics. LinkControl software: measurement plotter

 Open the catalog to page 3
LCA-2-4

allows the download of parameters from the sensor to the LCA-2 and the subsequent upload of these parameters to a different sensor. This way, sensor settings can be conveniently copied from one sensor to the other. Offline programming within LinkCopy With some sensor series, the sensor settings copied to the LCA-2 can be directly indicated and edited via the digital display before being written back into a sensor. For the LinkCopy function, the LinkControl adapter need not be connected to a PC. The LCA-2 reads the parameters out of the sensor and saves them internally to its EEPROM. The data are...

 Open the catalog to page 4
LCA-2-5

Which sensor families support LinkControl and LinkCopy? Cylindrical Sensors

 Open the catalog to page 5
LCA-2-6

Valid LinkControl from Version 8.1 (Rev. A) Cubic Sensors Special Sensors

 Open the catalog to page 6
LCA-2-7

This version supplies our new sensors: pms, pico+, pico+TF, cube , lcs+, hps+, dbk+, esp-4, esf-1/xx/yy/A and bks+. For an update we recommend to delete the existing LinkControl software under Windows beforehand.

 Open the catalog to page 7
LCA-2-8

scale drawing detection zone operating mode accessories description For the convenient setting of a large number of microsonic sensor families. The LinkControl-Adapter LCA-2 can be used to read, copy or write parameters. Additionally, you can connect it with a PC in order to configurate it via LinkControl Software. electrical data operating voltage UB 12 - 30 V d.c., reverse polarity protection no-load current consumption < 25 mA type of connection 4-pin M12 initiator plug inputs technical features/characteristics controls 4 push-buttons + LED display (TouchControl) The content of this document...

 Open the catalog to page 8
LCA-2-9

operating mode accessories description Set for convenient setting of a number of microsonic sensor families. - Adaptor for sensors with cable connection (lcs) incl. cable clamps - Adapter for power supply incl. cable clamps - Power supply 90-240VAC/24VDC, 625 mA, with 2,5 m cable - four exchangeable AC-plugs for use in Europe, USA, Great Britain and Australia - USB - cable A-plug to B-plug - USB stick with LinkControl software - Manual (German / English) particularities incl. adapter cable and 24V power pack operating voltage UB 12 - 30 V d.c., reverse polarity protection type of connection 4-pin...

 Open the catalog to page 9
LCA-2-10

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

 Open the catalog to page 10
LCA-2-11

scale drawing detection zone operating mode accessories description Connection of sensors with 4 contacts M12 or M8 connector at the LinkControl Adapter The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.