extract from our online catalogue: hps+ ultrasonic level sensors current to: 2026-10-09 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® ist eine eingetragene Marke der microsonic GmbH. Alle Rechte vorbehalten. Änderungen vorbehalten.
Open the catalog to page 1hps+ hps+ in safety gear - When you need chemically resistant, pressure-resistant sensors. Highlights > Optionally used in normal pressure or overpressure > PTFE membrane > for protection against aggressive media > Stainless-steel or optional PVDF housing for hps+340 > for use in the food industry > Sealed against the housing with an O-ring made from FFKM > for the highest possible chemical resistance > Digital display with direct measured value output in mm/cm or % > Numeric configuration of the sensor using digital display > UL Listed > to Canadian and US safety standards Basics > 2 switching...
Open the catalog to page 2For fill level measurements of aggressive media and in overpressure the ultrasonic transducers of the new hps+ sensors are now fitted out - as standard - with a PTFE film. It is sealed with a FFKM O-ring against the housing made of 1.4571 stainless steel or PVDF. This ensures a high degree of resistance to aggressive media. Fill level measurement in tanks hps+340 in highly resistant PVDF housing - PTFE protective film sealed with an O-ring made from FFKM against the housing The hps+ sensors can be used for fill level measurement under normal pressure or in tanks and containers with an overpressure...
Open the catalog to page 3Two different output stages are available for four detection ranges: 2 switching outputs in pnp switching 1 analogue output with an additional Sensors with switching output have three operating modes: Single switching point Two-way reflective barrier Window mode Two three-colour LEDs always show the current state of the switching outputs or the analogue output. With TouchControl all configuration can be done right at the sensor. The easily legible three-digit LED display continually shows the current distance value and automatically switches between millimetre and centimetre displays. Setting...
Open the catalog to page 4Sensor connected to the PC via LCA-2 for programming You have special requirements? Nothing as simple as that. With us, you can easily find an individual solution. Let us talk about your application: +49 231 97 51 51-82. hps+ ultrasonic level sensors
Open the catalog to page 5scale drawing scale drawing 1 x pnp + 1 xanalogue 4-20 mA □>ni / 0-10 V design process connection G1 operating mode proximity switch/reflective reflective barrier window mode analogue distance measurement particularities druckfest bis 6 bar Uber- hohe Chemiebestandigkeit design process connection G1 operating mode proximity switch/reflective reflective barrier window mode analogue distance measurement particularities druckfest bis 6 bar Uber- hohe Chemiebestandigkeit miCrOSOniC hps+ ultrasonic level sensors
Open the catalog to page 6transducer frequency blind zone operating range resolution switching hysteresis switching frequency response delay delay prior to availability 0.025 mm to 0.30 mm, depending on the analogue window ± 1 % (temperature drift internally compensated) 9 - 30 V d.c., reverse polarity protection analogue output current: 4-20 mA / voltage: 0-10 V, short-circuit-proof switchable rising/falling switching output NOC/NCC adjustable, short- synchronisation input transducer frequency blind zone operating range resolution switching hysteresis switching frequency response delay delay prior to availability 0.18...
Open the catalog to page 7material stainless steel, plastic parts: ultrasonic transducer coated with PTFE film, FFKM Technical Features/Characteristics play (TouchControl) scope for settings Teach-in and numeric confi guration via TouchControl LCA-2 with LinkControl material stainless steel, plastic parts: ultrasonic transducer coated with PTFE film, FFKM Technical Features/Characteristics play (TouchControl) scope for settings Teach-in and numeric confi guration via TouchControl LCA-2 with LinkControl miCfO/OniC hps+ ultrasonic level sensors
Open the catalog to page 8scale drawing scale drawing operating mode proximity switch/reflective reflective barrier window mode analogue distance measurement particularities druckfest bis 6 bar Uber- hohe Chemiebestandigkeit design process connection G2 operating mode proximity switch/reflective reflective barrier window mode analogue distance measurement particularities druckfest bis 6 bar Uber- hohe Chemiebestandigkeit miCrOSOniC hps+ ultrasonic level sensors
Open the catalog to page 9transducer frequency blind zone operating range resolution switching hysteresis switching frequency response delay delay prior to availability 0.18 mm to 1.5 mm, depending on the analogue window ± 1 % (temperature drift internally compensated) 9 - 30 V d.c., reverse polarity protection analogue output current: 4-20 mA / voltage: 0-10 V, short-circuit-proof switchable rising/falling switching output NOC/NCC adjustable, short- synchronisation input transducer frequency blind zone operating range resolution switching hysteresis switching frequency response delay delay prior to availability 0.18...
Open the catalog to page 10material stainless steel, plastic parts: ultrasonic transducer coated with PTFE film, FFKM Technical Features/Characteristics play (TouchControl) scope for settings Teach-in and numeric confi guration via TouchControl LCA-2 with LinkControl material stainless steel, plastic parts: ultrasonic transducer coated with PTFE film, FFKM Technical Features/Characteristics play (TouchControl) scope for settings Teach-in and numeric confi guration via TouchControl LCA-2 with LinkControl miCfO/OniC hps+ ultrasonic level sensors
Open the catalog to page 11hps+25/DD/TC/E/G1 scale drawing scale drawing 1 x pnp + 1 x analogue 4-20 mA / 0-10 V design process connection G2 operating mode proximity switch/reflective reflective barrier window mode analogue distance measurement particularities druckfest bis 6 bar Uber- hohe Chemiebestandigkeit operating mode proximity switch/reflective mode reflective barrier window mode hohe Chemiebestandigkeit Ultrasonic-Specific means of measurement echo propagation time accuracy ± 1 % (temperature drift in ternally compensated) miCrOSOniC hps+ ultrasonic level sensors