Catalog excerpts
Specification Product Product type Radial blower Standard Product Electronic commutated Motor (brushless, sensorless) Neodymium - Ferrite Magnet 2 Ball bearings Motor Electronic Integrated 3 phase Motor controller from Micronel Motor support Mat. Aluminium, anodised, natural colour Heat sink Mat. Aluminium, anodised, natural colour Electric connection Lead wire AWG 24, UL1007, PVC Length see dimensional drawing.
Open the catalog to page 1Operating range Nominal voltage Voltage range Current Power Speed Air flow Typ. Working point Current (Appr. 50% Qmax) Power Speed Air flow Pressure Static pressure Free blowing Current Power Speed Pressure Airflow [l/min]
Open the catalog to page 2Maximum speed Max. allowed temperature on heat sink surface: Blower limits Exceeding the blower limits during continuous operation may cause permanent damage! Handle only in currentless condition! Information Heat sink temperature increase, freeblowing Heat sink temperature increase, static pressure Power supply requirements Ripple voltage < 5% 3000 mA (nominal voltage) Acoustic emission level at nominal voltage Balancing class 10’000h at nominal voltage Outlet orifice: 6.52 mm Ambient temperature: 25°C Cycle: 24h on Air quality: free of dust, fumes and unnatural concentrations of gases....
Open the catalog to page 3Dimensional Drawing
Open the catalog to page 4Electrical circuit Lead wire Diagram Frequency Generator GND Ground Electrical features Speed calculation Integrated speed control input FG Frequency signal output ON / OFF control by logic signal Locked rotor protection Polarity protection Integrated thermal protection (IC temp. > 165°C switch off) Input / output ESD protected f*20 = rpm (3 pulse / rotation) f = FG Frequency Generator rpm = Rotation speed [min-1] Supply voltage Tacho Frequency VP Pull-up resistor (22kOhm) to 5 V is integrated Do not connect to Vcc!
Open the catalog to page 5 Stop Starting (not guaranteed) Fan is running compare to VDC Fan is running with 100% speed Input resistor Connect between SP (green) and GND (black) < 0.4 kΩ Stop 0.4 – 1.2 kΩ Starting (not guaranteed) 1.2 – 7.5 kΩ Fan is running compare to VDC > 7.5 kΩ Fan is running with 100% speed SP not connected SP to GND Blower operates at 100% Spee
Open the catalog to page 6Document: CE-KE-X2012-U-Line.pdf Document: Conformity-Declaration_Micronel.pdf Additional document Disclaimer All data can be subject to change without advanced notice. Performance data Revision Values listed are nominal and can vary due to component tolerances. Basic Spec. Spec. updated Spec. updated New: do not connect Vcc (FG signal) Performance update Spec. updated, new layout
Open the catalog to page 7All Micronel catalogs and technical brochures
-
U51HP-012KM-43
7 Pages
-
U51HP-024KM-43
7 Pages
-
U65H4-024KX-6
5 Pages
-
U71HL-024KM-4
6 Pages
-
U85HL-024KH-4
7 Pages
-
Specification D241P-006KH-4
6 Pages
-
Specification D301P-006KH-4
6 Pages
-
Specification D601P-024KM-4
7 Pages
-
Specification D341P-024KM-4
6 Pages
-
Specification U100HL-024KA-4
7 Pages
-
Specification U100H4-024KA-4
6 Pages
-
Specification U85MX-024KE-5
5 Pages
-
Specification U85MX-024KE-4
6 Pages
-
Specification U65ML-024KT-5
5 Pages
-
Specification U65ML-012KS-5
5 Pages
-
Specification U65MN-024KS-5
5 Pages
-
Specification U65HN-024KS-6
5 Pages
-
Specification U51D2-024KX-6
5 Pages
-
Radial Blower U65MN-024KS-6
5 Pages
-
Radial Blower U51DL-024KK-4
7 Pages
-
Specification U51DL-024KK-5
5 Pages
-
U51DX-024KK-5
5 Pages
-
U51DX-012KK-5
5 Pages
-
U51DL-012KK-5
5 Pages