Specification U85MX-024KX-5 - 1

General information item Product type Part no. Customer Project no. Modification Radial blower U85MX-024KX-5 U85MX-024KX-51 with inlet port (option) U85MX-024KX-52 with outlet port (option) U85MX-024KX-53 with inlet and outlet port (option) N/A N/A Standard product Description The versatile, high-power blower can be widely used for industrial or medical applications, where highest vacuum or pressure performance is needed, i.e. for cough therapy, dental suction, vacuum handling and many more. Features • Static pressure: 123 hPa, freeflow: 860 l/min • 21 VDC brushless motor with Hall sensors • Highly efficient, quiet operation • Mounting flange with holes • Molex connector • 40% oxygen resistant airway General Conditions Unless otherwise stated all data are measured at nominal voltage and are valid at 20 °C ambient temperature and 1.2 kg/m3 standard air density. Values listed are nominal and can vary depending on the installation conditions and due to component tolerances. Test setup according to ISO 5801 with standardized inlet and outlet chambers. Tolerances based on specified speed data according to ISO 13348, grade 4: pressure +/-10 %, power +16 %. Tolerances based on constant voltage: speed +/-10 %, pressure +/-21 %, power +33 %. For continuous blower operation please refer to specified maximum ratings. Performance data outside normal operating range plotted for information only.

Open the catalog to page 1
Specification U85MX-024KX-5 - 2

Performance Pressure vs. Flow Characteristics Flow rate [cfm] 0.0 180 Flow rate [l/min] Speed and Power vs. Flow Characteristics Flow rate [cfm] 0.0 50 Flow rate [l/min] Shut-Off in Pressure Operation (Zero Flow Rate) Static pressure Power consumption Shut-Off in Vacuum Operation (Zero Flow Rate) Static pressure Power consumption Free-Air (Zero Static Pressure) Flow rate Power consumption

Open the catalog to page 2
Specification U85MX-024KX-5 - 3

micronelTechnical Data Electrical Unit Value Nominal supply voltage [VDC] 21 Supply voltage range [VDC] 15 to 24 Maximum Ratings for Continuous Operation Minimum flow rate [l/min] 80 Maximum acceleration [rpm/ms] 100 Maximum power consumption [W] 160 Maximum housing surface temperature [°C] 65 Environmental Ambient temperature (operating) [°C] -20 to 45 Ambient temperature (storage) [°C] -20 to 65 Relative humidity (non-condensing) [%RH] 10 to 85 Winding insulation class Phase to phase resistance Phase to phase inductance Speed constant Torque constant Number of pole pairs Hall sensor type...

Open the catalog to page 3
Specification U85MX-024KX-5 - 4

Drawings Dimensions in mm 55A TO,6 streched length 290 ± 10mm Orientations Direction of rotation (j- Counter-clockwise (view on inlet) Mounting position Any direction Materials Components Fan housing Material Impeller Hub Motor housing Label Connector Crimp terminal Lead wire Polycarbonate (PC) Flammability: Glow wire flammability index 850 °C / 1 mm (IEC 60695-2-12) Biocompatibility: USP Class VI / ISO 10993 Polyamide (PA6) Stainless steel Zinc die cast Aluminum, anodized, natural color Plastic Molex Mini-Fit 39-01-2080 Flammability: UL 94V-2 Molex Mini-Fit 39-00-0038 Silicone insulated...

Open the catalog to page 4
Specification U85MX-024KX-5 - 5

identification Label Design Part number Nominal voltage Identification number: • Year, calendar week (YYWW) • Fabrication number (6 digits) • Serial number (3 digits) Options for inlet and Outlet Connections1 Part no. with options inlet Outlet U85MX-024KX-5 U85MX-024KX-51 • Handle in power-off conditions only! Read operating manual! Please see separate accessories list or contact Micronel Sales for a full list of options and accessories. Micronel AG Zurcherstrasse 51 CH - 8317 Tagelswangen The drawings show inlet and outlet connectors. Both options are independet of each other. No...