video corpo

Specification D301P-006KH-4
6Pages

{{requestButtons}}

Catalog excerpts

Specification D301P-006KH-4 - 1

micronelSpecification Tube Fan D301P-006KH-4 General Information Item Product type Tube fan with integrated electronic motor driver D303P-006KH-4 with flange at outlet (option) D304P-006KH-4 with flange at inlet (option) Customer N/A Modification Standard product Description In contrast to the Flat Fans, the Micronel Tube Fans offer increased pressure performance while still maintaining a high volume flow. They all feature extremely quiet and efficient operation while offering extreme reliability and life expectancy. Features • Static pressure 3.37 hPa, freeflow 310 l/min • 6 VDC brushless DC-motor • Speed control and tacho frequency signal • Small dimensions through slim design • Options for mounting flange with holes General Conditions Unless otherwise stated all data are measured at nominal voltage and are valid at 20 °C ambient temperature and 1.2 kg/m3 standard air density. Values listed are nominal and can vary depending on the installation conditions and due to component tolerances. Test setup according to ISO 5801 with standardized inlet and outlet chambers. Tolerances based on specified speed data according to ISO 13348, grade 4: pressure +/-10 %, power +16 %. Tolerances based on constant voltage: speed +/-10 %, pressure +/-21 %, power +33 %. For continuous blower operation please refer to specified maximum ratings. Performance data outside normal operating range plotted for information only.

Open the catalog to page 1
Specification D301P-006KH-4 - 2

Performance Pressure vs. Flow Characteristics Flow rate [cfm] 0.0 6 Flow rate [l/min] Speed and Power vs. Flow Characteristics Flow rate [cfm] 0.0 28 Flow rate [l/min] Shut-Off in Pressure Operation (Zero Flow Rate) Static pressure Power consumption Flow rate Power consumption Free-Air (Zero Static Pressure)

Open the catalog to page 2
Specification D301P-006KH-4 - 3

micronelTechnical Data Electrical Nominal supply voltage Supply voltage range Minimum power supply current 111 Maximum start-up time Maximum ripple voltage Maximum Ratings for Continuous Operation Minimum flow rate [l/min] N/A Maximum acceleration [rpm/ms] N/A Maximum power consumption [W] N/A Maximum housing surface temperature [°c] N/A Environmental Ambient temperature (operating) [°C] 0 to 65 Ambient temperature (storage) [°C] 0 to 65 Relative humidity (non-condensing) [%RH] 10 to 85 Motor Type Brushless direct current motor Winding insulation class H, 180 °C Acoustics Sound pressure...

Open the catalog to page 3
Specification D301P-006KH-4 - 4

Orientations Direction of rotation O Clockwise (view on inlet) Mounting position Any direction Flammability: UL 94V-1 Impeller Polyphenylenoxide (PPO) Motor housing - Crimp terminal - Lead wire Silicone insulated cable

Open the catalog to page 4
Specification D301P-006KH-4 - 5

micronelIdentificationLabel Design Part number Nominal voltage micronel Micronel AG CH-8317 Tagelswangen Micronel Tube Fan D301 P-006KH-4 2331 999999 001 -6VDC Identification number: • Year, calendar week (YYWW) • Fabrication number (6 digits) • Serial number (3 digits) Blower PinoutPin Color Description AWG Red Black Yellow Green Tachometer output Set speed input Electronic Functions Integrated Electronic Motor Driver Type Sensorless brushless direct current motor driver Features • Integrated speed control (PWM) • Tachometer frequency signal • Locked rotor protection • No polarity...

Open the catalog to page 5
Specification D301P-006KH-4 - 6

micronel Electronic Functions Set Speed Input PWM [%] Set speed not connected 0.0 0.1 to 9.0 10.0 10.0 to 100.0 (after start-up) Frequency 15 kHz - 25 kHz; (TYP 20 kHz) Operation Mode Fan speed at 100 % Stop Not defined, fan might run or stop Minimum start-up Fan speed depending on duty cycle Product no. with options Flange Inlet Flange Outlet Micronel Tube Fan D301P-006KH-4 Micronel Tube Fan D303P-006KH-4* • Micronel Tube Fan D304P-006KH-4* • * The drawings show versions of flange. Micronel Tube FanD303P-006KH-4 Handle in power-off conditions only! Read operating manual! Please see...

Open the catalog to page 6

All Micronel catalogs and technical brochures