Smart VacPrep Gas Adsorption Sample Preparation Device “Rapid-Start” Push Buttons for Quick Start-and-Stop Degassing The new Smart VacPrep is an advanced six-port system that utilizes vacuum to prepare samples by heating and evacuation. Each of the ports may be operated independently. Samples may be added or removed from degas ports without disturbing the treatment of other samples undergoing preparation. Degassing automatically terminates when the samples have completed all programmed steps. The Smart VacPrep software includes a set of default ramp and temperature parameters. However, you also have the option of programming each port with a different set of parameters. A record of the sample preparation time and temperature can be recorded as part of the sample data file. The degas program may be started or terminated by using software installed on the computer attached to the analysis instrument or with push-buttons on the front panel of the Smart VacPrep. This time-saving, ‘Rapid-Start’ mode on each port gives you the ability to walk up to the instrument, attach the sample tube with heating mantle, and immediately start degassing a sample. Features: • High-throughput sample preparation with six independently controlled ports • Preprogrammed ramp rates and temperatures allow for quick startup • Create SOP methods through customizable degassing protocols with Windows® software • Programmable pressure threshold can suspend the temperature ramp if the outgassing pressure exceeds the amount specified • Status indicators at each port allow instant identification of completed sample degas routines • Sample ports can accept 9 mm, 12 mm, 1/2 inch, and 3/8 inch sample tubes • Compatible with 3FlexTM, ASAP® 2460, TriStar® II, and TriStar® II Plus
Open the catalog to page 1Smart VacPrep Gas Adsorption Sample Preparation Device Specifications:* Capacity: Degas Method: Vacuum Control: Servo-controlled rates to minimize or eliminate sample elutriation Evacuation Rate: Selectable evacuation rate from 1.0 to 50.0 mmHg/s Heating mantles Temperature Range: Temperature Control: One ramp during evacuation phase, five additional ramps during subsequent phases Temperature Accuracy: Deviation less than ±10 ºC at the sensing thermocouple embedded in the heating mantle Heating Ramp Rate: Selectable from 0.1 ºC per minute to 10 ºC per minute Hold Time: Zero to 999 minutes...
Open the catalog to page 2All Micromeritics Instrument Corp. catalogs and technical brochures
-
Elzone® II 5390
8 Pages
-
ChemiSorb HTP
2 Pages
-
ChemiSorb™ Series
8 Pages
-
ASAP™ 2050
8 Pages
-
ACCUPYC II 1345
16 Pages
-
The Model 021 LN2
2 Pages
-
ElectroPrepTM 053
2 Pages
-
MicroActive
2 Pages
-
AutoPore™ IV Series
6 Pages
-
Saturn DigiSizer II
6 Pages
-
Elzone® II 5390
8 Pages
-
3Flex
9 Pages
-
AutoChem II 2920
5 Pages
-
ASAP 2460
5 Pages
-
TriStar II PLUS
6 Pages
-
ASAP 2420
5 Pages
-
GeoPyc® 1365
4 Pages
-
DVVA II
2 Pages
-
FlowSorb III 2305 / 2310
2 Pages
-
Gemini® VII 2390
8 Pages
-
ASAP 2020 Plus
6 Pages
-
AutoPore V
8 Pages
-
SediGraph III PLUS
6 Pages
-
Chemisorption Series
8 Pages
-
AutoChem 2950 HP
8 Pages
-
Micromeritics Products Brochure
11 Pages