FlowSorb III 2305 / 2310
2Pages

{{requestButtons}}

Catalog excerpts

FlowSorb III 2305 / 2310 - 1

• Ultra-stable detector eliminates drift and the need for constant readjustment • Cold trap conveniently located in front vs. side placement, as in other instruments. This placement reduces the chance of breakage. • Single injection calibration requires only one control setting. Adaptable to any non-corrosive adsorbate mix. • All controls and displays are at eye/ arm level, out of the spill zone • Built-in sample preparation • Rugged construction for day-in, day-out operation The Flowsorb III 2305 / 2310 provides single-point and multipoint BET surface area measurements with speed, accuracy, and reliability. Samples having surface areas from 0.01 m2/g to over 1,000 m2/g are easily accommodated. The FlowSorb III’s reproducibility is better than 0.5%. The FlowSorb III 2310 features a built-in Dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of the sample analysis. Single injection calibration provides fast start-up and high sample throughput. Specially designed sample holders can be attached and removed from the instrument with one hand. These quick connect/disconnects have a built-in isolation valve to prevent sample contamination. The FlowSorb III 2305 features a Dewar support latch system that provides onehanded convenience and safe-guards against LN2 spills. Simple in design, the Flow-Sorb III requires minimal training time and leaves little chance of operator error. Automatic mode switching for adsorption and desorption is accomplished without operator attention. The low purchase price of the FlowSorb III and its accessories make this instrument one of the most inexpensive ways for a laboratory to begin measuring BET surface area. Five different types of sample tubes, including a monolith type tube for large samples, are available. M micromeritics® The Science and Technology of Small Particles™ Micromeritics Instrument Corporation 4356 Communications Dr., Norcross, GA 30093, USA US Sales: 770.662.3633, International Sales: 770.662.3660 Customer Orders: 770.662.3636, FAX: 770.662.3696

Open the catalog to page 1
FlowSorb III 2305 / 2310 - 2

Specifications Applicability Surface Area: 0.1 m2 (minimum) 280 m2 (maximum) Specific Surface Area: Approximately 0.01 m2/g (minimum) Accuracy / Reproducibility Low Specific Surfaces: Typically better than ± 3% (single-point method); ± 2% (multipoint method) reproducibility within ± 0.5% Moderate-to-high Specific Surfaces: Typically better than ± 2% (single point method); ± 1.5 (multipoint method) reproducibility within ± 0.5% System Capacity Sample holder volume: Degas System Temperature Range: Selection: Accuracy: Electrical Voltage: Frequency: Power: Environment Temperature:...

Open the catalog to page 2

All Micromeritics Instrument Corp. catalogs and technical brochures

  1. ASAP™ 2050

    8 Pages

  2. MicroActive

    2 Pages

  3. 3Flex

    9 Pages

  4. ASAP 2460

    5 Pages

  5. ASAP 2420

    5 Pages

  6. DVVA II

    2 Pages

  7. AutoPore V

    8 Pages

Archived catalogs