Group: Wölfel GmbH
Catalog excerpts
INCLINOMETERS DUAL AXIS INCLINOMETERS DESIGNED TO WITHSTAND HARSH OPERATING CONDITIONS Those dual axis inclinometers are designed to measure very small changes from the vertical level, either on the ground or in structures. They exhibit high resolution and low thermal drift. Their mechanical design and enhanced internal surge protection make them particularly useful for the permanent outdoor monitoring of structures being subjected to various influences such as loading and foundation settlement.
Open the catalog to page 1Off-shore wind turbine foundations Bridges and piers Historical buildings Structural load testing Vessel and pontoon roll and pitch measurement Crane roll and pitch measurement Structural Health Monitoring Biaxial High accuracy and resolution Excellent thermal stability 4-20 mA current loops for signal immunity and potentially long cable runs Enhanced surge protection Internal temperature sensor for residual thermal drift compensation Two models for horizontal or vertical mounting Easy to install Robustness to environmental conditions Short-term or permanent long-term monitoring Monitoring...
Open the catalog to page 2CHARACTERISTICS Tilt angle Channel Characteristics Test Condition Measuring range M ONIT O RIN G Max. Unit SOLUT IO NS Sensitivity change with Temperature Offset change with Temperature Sensitivity error Output resolution Output noise density Cross Axis Sensitivity 2nd order low-pass filter cutoff frequency The angle output has SIN curve relationship to current output Resolution = Noise density * √(bandwidth) Temperature Channel Characteristics Parameter Test Condition Measurement range Accuracy Temperature noise density 2nd order Butterworth low-pas
Open the catalog to page 3Temperature Sensor Response Curve Power Supply Parameter Test Condition
Open the catalog to page 4REFERENCE DIRECTIONS
Open the catalog to page 5RESPONSE Horizontal Mounting Model Vertical Mounting Model
Open the catalog to page 6CERTIFICATIONS Electromagnetic Compatibility M ONIT O RIN G SOLUT IO NS Limit / Level Emission FCC 47 Part 15 Radiated Emission Immunity EN 61000-4-2 Electrostatic Immunity EN 61000-4-3 Radiated, radio frequency, electromagnetic field immunity EN 61000-4-4 Electrical fast transient / burst immunity 2 kV – 100 kHz on signal lines Criterion B EN 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8 Power frequency magnetic field immunity Continuous field 30 A/m Short duration field 100 A/m 50 & 60 Hz Criterion A Operating Temperature Standard Limit /...
Open the catalog to page 7NOTE • When ordering with cable connections, cable is mounted at the factory. Please specify required length. • Standard cable gauge is 0.25 mm² (AWG24). Higher cable gauge might be required for long cable runs. • Residual Output Drifts vs. T° are given for the range -10°C to +40°C by default ENGINEERING SERVICES • • • • • • Special coatings Special cables Integration with monitoring systems and cloud platform Adaptations for underwater use Adaptations for marine environment Other temperature range for residual output dri
Open the catalog to page 8All Micromega Dynamics catalogs and technical brochures
-
IAC_Accessories
3 Pages
-
Recovib Shiver
6 Pages
-
Recovib Monitor 4 & 8
8 Pages
-
Structural Health Sensors
7 Pages
-
IAC-UHRS-Ud-03
4 Pages
-
IAC-UHRS-Ud-02
4 Pages
-
IAC-UHRS-Ud-01
4 Pages
-
IAC-UHRS-I-03
4 Pages
-
IAC-UHRS-I-02
4 Pages
-
IAC-UHRS-I-01
4 Pages
-
IAC-MR-I-03
4 Pages
-
IAC-MR-I-02
4 Pages
-
IAC-MR-I-01
4 Pages
-
IAC-I-01-S
3 Pages
-
IAC-U-03
4 Pages
-
IAC-U-02
4 Pages
-
IAC-U-01
4 Pages
-
IAC-I-03
4 Pages
-
IAC-I-02
4 Pages
-
IAC-I-01
4 Pages
-
IAC-HiRes-I-01
4 Pages
-
IAC-HiRes-I-02
4 Pages
-
IAC-HiRes-I-03
4 Pages
-
IAC-HiRes-Ud-01
4 Pages
-
IAC-HiRes-Ud-02
4 Pages
-
IAC-HiRes-Ud-03
4 Pages
-
IAC-CM-U-02
4 Pages
-
IAC-CM-I-01
4 Pages
-
IAC-CM-I-02
4 Pages
-
IAC-CM-I-03
4 Pages
-
IAC-CM-U-01
4 Pages
-
IAC-CM-U-03
4 Pages
-
Recovib io Cloud Interface
8 Pages
-
WIND ENERGY PORTFOLIO
3 Pages
-
Recovib Feel 2/6G
5 Pages