IAC-U-01

IAC-U-01

IAC-U-01

Product catalog summary
Overview: The IAC-U-01 is a robust accelerometer designed for industrial applications, offering reliable performance with a single-axis measurement capability. It is suitable for direct connection to standard control and measurement equipment such as PLCs and panel meters.
Key Properties:
  • Single-axis measurement.
  • Embedded 0-3V signal conditioning.
  • Galvanically isolated and protected against false polarization.
  • Compact and rugged design with IP67 protection grade.
Output and Channel Specifications:
  • Output range: 0-3.0 V.
  • Supply voltage: 12-30 V.
  • Measuring range: ±2g or ±6g.
  • Sensitivity: 0.6 V/g (±2g range) or 0.2 V/g (±6g range).
  • Frequency limits: Lower limit at 0 Hz (DC), upper -3 dB frequency limit at 100, 250, 500, or 1000 Hz.
  • Non-linearity: ±0.5% F.S.
  • Residual noise: < 50 µg/√Hz.
  • Transverse sensitivity: < 5%.
  • Destruction limit: ±5000g.
Environmental Characteristics:
  • Operating temperature range: -20 to 85°C (-4 to 185°F).
  • Non-operating temperature range: <-40 or >85°C (<-40 or >185°F).
  • Temperature coefficient of sensitivity: ±0.01%/°C.
  • Temperature drift of zero point: ±0.5 mg/°C.
Mechanical Data:
  • Weight without cable: CG/75, CO/102 for stainless steel; CG/42, CO/68 for aluminium.
  • Case material: Stainless steel (AISI316) or aluminium (MIL-A-8625 Type II coating).
  • Mounting: 3.2 mm diameter holes (4x).
Electrical Connections:
  • Cable Gland Model and M12 Connector Model available.
  • Signal sensing for X, Y, Z axes with specific color-coded wiring.
Ordering Information:
  • Options for low pass filter frequencies: 100Hz, 250Hz, 500Hz, 1000Hz.
  • Cable length specified in meters.
  • Choice of casing material: Aluminium or Stainless Steel.
  • Measurement range options: ±2g or ±6g.
See more

Catalog excerpts

IAC-U-01-1

ROBUST ACCELEROMETER BLOCK DIAGRAM 1 axis Suited for direct connection to standard control and measurement equipment, e.g., PLCs or panel meters. Embedded 0..3V signal conditioning Galvanically Isolated Protected against false polarization. Compact and rugged design Protection

 Open the catalog to page 1
IAC-U-01-2

DIMENSIONS – Cable Gland Model DIMENSIONS – M12 Connector Model MOUNTING ACCESSORIES See “IAC – Accelerometer Accessories data s

 Open the catalog to page 2
IAC-U-01-3

SPECIFICATIONS – ALL MODELS Output Range Supply Voltage Measuring Range Lower frequency limit Upper -3 dB frequency limit Residual noise Transverse sensitivity Destruction limit Temperature range ENVIRONMENTAL CHARACTERISTICS Temperature coefficient of sensitivity ± 0.01 %/°C Temperature drift of zero point Protection grade Weight Without Cable (g) MECHANICAL DATA Case Material Stainless Steel or Aluminium Stainless Steel Casing AISI316 Grade (e.g. for offshore/marine environment) Aluminium (MIL-A-8625 Type II coating) ELECTRICAL CONNECTIONS – Cable Gland Model Signal X sensing Sensor supply...

 Open the catalog to page 3
IAC-U-01-4

Cable Connection Cable Gland Stainless Steel Cable Length

 Open the catalog to page 4

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.