IAC-CM-U-03

IAC-CM-U-03

IAC-CM-U-03

Product catalog summary
Properties
  • 3-axes accelerometer with a wide bandwidth of 0 – 24kHz.
  • Embedded signal conditioning with a 0 – 5V output range.
  • Self-powered current loop and galvanically isolated.
  • Protected against false polarization with a compact and rugged design.
  • IP67 ingress protection grade.
Specifications
  • Output Range: 0-5V with a supply voltage of 12-30V.
  • Bandwidth: 0-24kHz (-3dB).
  • Non-linearity: 0.5% F.S. typical, 1.5% F.S. maximum.
  • Sensitivity Error: 2%.
  • Transverse Sensitivity: 2% typical, 5% maximum.
  • Offset dispersion: ±1g typical, ±2g maximum.
  • Destruction limit: 1000g.
Environmental Characteristics
  • Operating Temperature Range: -40 to 125°C / -40 to 185°F.
  • Non-Operating Temperature Range: <-55 to >125°C / <-67 to >257°F.
  • Sensitivity drift: ±500ppm/°C.
  • Offset drift: ±50mg/°C.
  • Ingress protection grade: IP67.
Mechanical Data
  • Weight without cable: CG/75g, CO/102g for stainless steel; CG/42g, CO/68g for aluminium.
  • Case Material: Stainless Steel (AISI316) or Aluminium (MIL-A-8625 Type II coating).
  • Mounting: 3.2mm diameter holes (4x).
Performance by Model
  • Range and Sensitivity: +/- 25g (80 mV/g), +/- 50g (40 mV/g), +/- 100g (20 mV/g), +/- 200g (10 mV/g), +/- 500g (4 mV/g).
  • Frequency Response: 0 - 10kHz for lower ranges, 0 - 24kHz for +/- 500g.
  • Noise: Ranges from 40 to 150 µg/√Hz depending on the model.
Electrical Connections
  • Cable Gland Model: X, Y, Z sensing signals with specific color-coded wires for sensor supply and output.
  • M12 Connector Model: Unipolar voltage outputs for X, Y, Z with designated pins for sensor supply.
Ordering Information
  • Model configuration includes options for cable length, connection type (Cable Gland or M12), casing material (Aluminium or Stainless Steel), and range (±25g to ±500g).
See more

Catalog excerpts

IAC-CM-U-03-1

ACCELEROMETER FOR CONDITION MONITORING 3-axes Wide bandwidth (0 – 24kHz) Embedded 0 – 5 V signal conditioning. Self-powered current loop Galvanically isolated Protected against false polarization. Compact and rugged design IP 67 ingress protection grade BLOCK DIAGRAM USER VOLTAGE REGULATOR

 Open the catalog to page 1
IAC-CM-U-03-2

DIMENSIONS – Cable Gland Model NOTE When mounted with sensing axis vertical all units will indicate 1 g offset due to gravity DIMENSIONS – M12 Connector Model MOUNTING ACCESSORIES See “IAC – Accelerometer Accessories data sheet

 Open the catalog to page 2
IAC-CM-U-03-3

SPECIFICATIONS – ALL MODELS Output Range Supply Voltage Non-linearity Sensitivity Error Transverse Sensitivity Offset dispersion Destruction limit Temperature Range ENVIRONMENTAL CHARACTERISTICS Offset drift Ingress protection grade Weight Without Cable (g) MECHANICAL DATA Sensitivity drift Case Material Stainless Steel or Aluminium Stainless Steel Casing AISI316 Grade (e.g. for offshore/marine environment) Aluminium (MIL-A-8625 Type II coating) PERFORMANCES – BY MODEL Range - g Noise - µg/√Hz ELECTRICAL CONNECTIONS – Cable Gland Model Signal X sensing Sensor supply + input Sensor supply - input...

 Open the catalog to page 3
IAC-CM-U-03-4

Voltage unipolar output Voltage unipolar output Voltage unipolar output Sensor supply + input Sensor supply - input ELECTRICAL CONNECTIONS Cable Connection Cable Gland Stainless Steel Cable Length

 Open the catalog to page 4

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.