The PD140 Lightning Protection Device is designed for outdoor transmitter applications to prevent damage from lightning strikes, inductive switches, and static discharge. It offers both common mode and differential mode protection, ensuring the normal operation of transmitters and reducing potential losses.

Features
  • Compatible with 4-20mA current loops and RS485 signal channels.
  • Self-resetting capability.
  • Quick response time.
  • IP65 housing protection.

Specifications
  • Max flow for RS485 signal interface: ≥5kA (8/20us wave).
  • Max flow for 4-20mA channel: ≥10kA (8/20us wave).
  • Operating temperature range: -40℃ to 80℃.
  • Limited voltage for 4-20mA channel: 28V (2-wire to earth and between 2-wire).
  • Limited voltage for RS485: -7V to 12V (2-wire to earth) and 6.5V (between 2-wire).
  • Max working current: <40mA for 4-20mA channel and <120mA for RS485 channel.
  • Installation: 3 bolts fixing or lead rail.

Order Notes
  1. Install the device as close as possible to the transmitter's protected side.
  2. Ensure the cable diameter through the fixed connector is between 5-10mm for optimal protection.
  3. Ensure proper system earthing with a cable less than 1m in length and a cross-section area of at least 4mm². The earthing resistor should be less than 4 Ohms.
  4. Be aware of voltage drop: less than 2VDC at 20mA and 25℃, and less than 6VDC at 80℃, which may affect the load.
See more

Catalog excerpts

PD140 PD140 Ligh-1

PD140 Lightning Protection Device PD140 Lightning-proof Protection Device Features •Suitable for 420mA current loop and RS485 signal channel •Self-resetting; •Effective to prevent transmitter damage from lightning, inductive switch and statis discharge; •Common mode (wire & wire) protection and differential mode (wire & earth) protection; •Response quickly; •Housing protection IP65 Introduction PD140 lightning-proof protection device is the new version which our company developed especially for transmitter outdoor application. Lightning strike is the main failure reason for level transmitter broken in outdoor measurement. PD140 device could reduce transmitter damage probability through inner protection components. It is effective to protect transmitter working normally and help customers to reduce losses. Specification •Max. flow of RS485 signal interface: •Max. flow of 420mA channel: •Operation temperature: •Limited voltage: (420mA channel2-wire to the earth 28V RS4852-wire to the earth -7V12V •Max. working current: 420mA channel<40mA •Installation: 3 bolts fixing / fixed by lead rail Outline Construction and Electric Connection input side output side (connect ing to transmit ter) http://www.microsensor.cn Address: No.,18, Yingda Rd, Baoji 721006, Shaanxi, China Tel: +86 917 3600755 /3600832

 Open the catalog to page 1
PD140 PD140 Ligh-2

PD140 Lightning Protection Device Order Notes 1. Please install the protection device to transmitter’s protected side as close as possible; 2. In order to keep good protection class, please be sure the cable, which passes through the fixed conector, has diameter bweteen 510mm; 3. Please be sure the system earthing well. The cable between wiring terminal and earth wire is 2 lessthan 1m, and cable cross section area is no less than 4mm . The earthing resistor should be less than 4 Ohms. 4、The lightning protection device has the certain voltage drop. At 20mA and normal temprature 25℃, the voltage...

 Open the catalog to page 2

All Micro Sensor Co.,Ltd catalogs and technical brochures

  1. tri-valve

    2  Pages

  2. MPM489WZ1

    3  Pages

  3. MPM6861G

    4  Pages

  4. M1500

    2  Pages

  5. MFE600

    24  Pages

  6. MPM484C

    3  Pages

  7. Flow Switch

    4  Pages

  8. Appendix 1151

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.