1. Catalogs
  2. Micro Sensor Co.,Ltd
  3. MFE600 Intelligent Electromagnetic Flowmeter

MFE600 Intelligent Electromagnetic Flowmeter

MFE600 Intelligent Electromagnetic Flowmeter
1 / 24 PagesView full catalog

MFE600 Intelligent Electromagnetic Flowmeter

Product catalog summary
Introduction
The MFE600 Intelligent Electromagnetic Flowmeter is a precision instrument for industries like petroleum, chemical, and water management. It offers advanced technology for stable performance, a user-friendly interface, and a dual-language LCD display.
Working Principle
Based on Faraday's Law of Electromagnetic Induction, the flowmeter measures the electromotive force in conductive liquids to determine flow rate. Accuracy depends on liquid conductivity, full pipe flow, and well-mixed components.
Features
The flowmeter boasts high accuracy unaffected by fluid properties, energy efficiency, sensitivity to transient flux, minimal installation requirements, corrosion-resistant materials, EEPROM for settings protection, low power consumption, multi-electrode structure, low-frequency excitation, and bidirectional measurement capability.
Performance
The converter processes signals proportional to flow, with outputs like 4-20mA DC, pulse, and alarm signals. Communication options include RS485 and RS232 protocols, with data protection via EEPROM.
Installation and Structure
Available in integrated and separated models, the flowmeter features robust housing with IP65 or IP68 protection. Installation options include flange and clamp-on types, with various lining and electrode materials.
Model Selection
Model selection considers fluid type, flow range, pressure, and temperature. The flowmeter supports various diameters and conditions, with guidelines for installation and operation.
Measurable Flux Range
A detailed table of flow ranges for different pipe diameters helps users select the appropriate model.
Electric Connection
Wiring recommendations include insulation, avoiding outdoor connections in rain, and using conduit tubes for protection.
Specifications and Installation Guidelines
Specifications include metal cable protection, waterproof seals, and grounding to prevent electric shocks and noise interference. Wire connection types are integrated and separated, each with specific uses.
Flowmeter Model Specifications
Specifications cover measurement pipe diameter, electrode type, lining material, pressure, temperature, protection level, converter type, signal types, housing materials, and power supply options.
Installation Considerations
Guidelines emphasize matching sensor and pipe diameters, maintaining full pipe conditions, and avoiding uneven fluid conductivity areas.
Pressure Loss and Pipe Installation
Pressure loss calculations and installation direction recommendations prevent issues like bubble formation and pipeline vibration stress.
Electrode Material Selection
Electrode material should match the corrosivity of the medium, with recommendations to consult anti-corrosion manuals or conduct tests.
Additional Recommendations
Ensure no air bubbles, use cut-off and bypass valves for maintenance, and align pipelines properly to prevent flange damage.
Material Compatibility and Limitations
Compatibility details for various acids and materials like Hastelloy C, Titanium, Tantalum, Platinum, and Tungsten Carbide are provided.
Material Selection for Ground Rings and Linings
Ground ring material should match electrode material, and lining material selection depends on fluid type and temperature.
Advantages of Specific Materials
Details on PTFE, F46, Polyurethane Rubber, Neoprene Rubber, and Ceramics highlight their specific advantages and limitations.
Protection Level Selection
Protection levels IP65, IP67, and IP68 are explained based on installation conditions.
Sensor Grounding and Noise Suppression
Grounding ensures reference potential matches liquid potential, and noise suppression involves avoiding installation near power devices.
See more

Catalog excerpts

MFE600 Intelligent Electromagnetic Flowmeter-1

MFE600 Intelligent Electromagnetic Flowmeter V1.2) ( MFE600 Intelligent Electromagnetic Flowmeter Introduction MFE600 Intelligent Electromagnetic Flowmeter is designed and manufactured with the most advanced domestic and abroad technology, featuring high accuracy, reliability, good stability and long service life. We pay our attention to every detail in the process of the product structure design, material selection, manufacturing, assembly and factory testing etc. With a water tower up to 35m as pressure stabilizer for actual flow calibration, we have a professional production line for electromagnetic flowmeter, also we design and develop a series of software and hardware for electromagnetic flowmeter for mass production to ensure high quality in long term use. The product has backlight and wide temperature-ranged Chinese/English LCD display. With fully practical function, visual display, easy operation, it saves troubles for on-site installation operation and maintenance. MFE600 can be widely used in industrial fields such as petroleum, chemical, metallurgy, water supply and drainage, steel, coal, paper, food, textile, environmental protection and other municipal administration, water conservancy construction field etc. Working Principle The working principle of Electromagnetic Flowmeter is based on Faraday's Law of Electromagnetic Induction, that is, when the conductive liquid flows through the electromagnetic flowmeter, the induced electromotive force will be produced in the liquid conductor, and the induced electromotive force is directly proportional to the velocity of conductive liquid, magnetic flux density and width of conductor (interior diameter of flowmeter). Such induced electromotive force is detected by a pair of electrodes on the tube wall of the flowmeter, and the rate of flow can be acquired by mathematical operation. The equation of induced electromotive force is as follows: E = K× V× B× D E: Induced electromotive force B: Magnetic flux density D: Interior diameter of measuring pipe http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China, Tel: +86 917 3600739/3600832

 Open the catalog to page 1
MFE600 Intelligent Electromagnetic Flowmeter-2

MFE600 Intelligent Electromagnetic Flowmeter V1.2) ( The following conditions should be satisfied in order to obtain satisfactory measuring accuracy: 1. The measured liquid shall posses the electrical conductivity; 2. The pipe shall be full of liquid; 3. The components of liquid shall be well mixed; 4. If the liquid has magnetic permeability, the magnetic field of the flowmeter will change, so the flowmeter shall be modified. During measurement, when the fluid flows through the magnetic field perpendicularly to the flow direction, the flow of the conductive liquid induces an electric potential...

 Open the catalog to page 2
MFE600 Intelligent Electromagnetic Flowmeter-3

MicroSensor MFE600 Intelligent Electromagnetic Flowmeter (V1.2) Performance Electromagnetic Flowmeter Converter Components: Input signal: signal emitted from the sensor directly proportional to the flow. Output signal: 4mA ~ 20mA DC (load resistance 0Q ~ 750Q). Select pulse / alarm output by parameter setup Pulse output: (pulled up resistor already) 4mA ~ 20mA DC Output: Current output is active output. Alarm output: rated value 30V DC, 100mA Communication signal: RS485 communication protocol (optional); RS232 communication protocol (optional) Load Resistance: 250Q ~ 600Q (including cable resistance) Load...

 Open the catalog to page 3
MFE600 Intelligent Electromagnetic Flowmeter-4

MFE600 Intelligent Electromagnetic Flowmeter (V1.2) Lower limit alarm: the transient flux is smaller than the lower limit of setting value Damping function: available to set from 0.2s ~ 100s (63% response time) Normal Working Condition Environment Temperature: -20°C~60°C Rated Voltage of Power Supply: 220V AC: 100V~240V AC DC: 24V DC Installation and Structure Installation: Separate model: converter, 50mm pipe or plane installation Integrated model: combined with the sensor Wire connector: ISO M20 x 1.5 female thread Wire Terminals: M3 screw Housing material: aluminum alloy Structure: Protection...

 Open the catalog to page 4
MFE600 Intelligent Electromagnetic Flowmeter-5

MFE600 Intelligent Electromagnetic Flowmeter V1.2) ( Diameter Excitation type Constant flux square wave excitation Mode Installation Installationflanged, Separatedflange, split flange Integrated form: an integral Flanged Lined :neoprene, urethane rubber, PTFE, F46 Neoprene, Polyurethane rubber, PTFE,F46 Electrode materials: 316L, Hc, Hb, titanium, tantalum, platinum iridium, tungsten 316L, Hc, Hb, Titanium, Tantalum, Platinum iridium, Tungsten carbide carbide Lining Electrode Material Grounding Ground :built-in ground electrode (DN25 and above) Built-in grounding electrode (DN25 and above) Media:...

 Open the catalog to page 5
MFE600 Intelligent Electromagnetic Flowmeter-6

MFE600 Intelligent Electromagnetic Flowmeter V1.2) ( Diameter Excitation type Constant flux square wave excitation Mode Installation Lining Electrode Material Grounding Medium Accuracy Grade Media Conductivity Velocity Pipe Connection Installation form: an integral flange, split flange Integrated clamp-on, Separated clamp-on Lined :neoprene, urethane rubber, PTFE, F46 Neoprene, Polyurethane rubber, PTFE,F46 Electrode materials: 316L, Hc, Hb, titanium, tantalum, platinum iridium, tungsten 316L, Hc, Hb, Titanium, Tantalum, Platinum iridium, Tungsten carbide carbide Ground :built-in ground electrode...

 Open the catalog to page 6
MFE600 Intelligent Electromagnetic Flowmeter-7

MFE600 Intelligent Electromagnetic Flowmeter (V1.2) d. Maximum temperature, minimum temperature. 2. The measured liquid shall have certain conductivity, electrical conductivity >5gS/cm. 3. The maximum flux and the minimum flux shall meet the values in the measurable flux range table. 4. The actual maximum working pressure shall be less than the rated working pressure of flowmeter. 5. The maximum working temperature and the minimum working temperature shall meet the temperature requirements stipulated for flowmeter. 6. Whether negative pressure exists or not in the processing pipeline shall be...

 Open the catalog to page 7
MFE600 Intelligent Electromagnetic Flowmeter-8

MFE600 Intelligent Electromagnetic Flowmeter (V1.2) Please notice the following suggestions when connecting wires: 1. In order to ensure interior insulation of sensor junction box, in case of the poor insulation caused by moisture, it is not suggested to connect cable outdoors in the raining weather. 2. When connecting the power cable and signal cable, both ends of the cable should be wrapped with circular lugs. 3. Conduit tube is suggested to use. The conduit tube material can use thick and sturdy steel pipe or flexible metal pipe. 4. All the power cable and non 4-core 24V DC signal cable must...

 Open the catalog to page 8

All Micro Sensor Co.,Ltd catalogs and technical brochures

  1. tri-valve

    2  Pages

  2. MPM489WZ1

    3  Pages

  3. MPM6861G

    4  Pages

  4. M1500

    2  Pages

  5. MFE600

    24  Pages

  6. MPM484C

    3  Pages

  7. Flow Switch

    4  Pages

  8. Appendix 1151

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.