MDM3051S -DGP-DAP
10Pages

{{requestButtons}}

Catalog excerpts

MDM3051S -DGP-DAP - 1

MDM3051S-DGP/DAP Intelligent Pressure Transmitter MICRO SENSOR CO.,LTD.

Open the catalog to page 1
MDM3051S -DGP-DAP - 2

MICRO SENSOR CO.,LTD http://www.microsensor.cn Address: No.18 Yingda Rd, Baoji, Shaan Xi, China, 721006 Tel: +86 0917 3600739/3600832 Fax: +86 917 3609977

Open the catalog to page 2
MDM3051S -DGP-DAP - 3

MDM3051S Intelligent PressureTransmitter Brief Introduction Bracket Installation Gauge Pressure Transmitter (DGP) Bracket Installation Absolute Pressure Transmitter (DAP) Measured media: gas, steam, liquid Measured range(with no shift): 0Pa~600Pa...40MPa Basic error: ±0.075% Diaphragm contacting with liquid: Stainless Steel 316L, Hast-alloy MDM3051S-DGP Bracket Installation Gauge Pressure Transmitter MDM3051S-DAP Bracket Installation Absolute Pressure Transmitter MDM3051S series Bracket Installation Gauge/Absolute Pressure Transmitter is used for level, density and pressure measurement of...

Open the catalog to page 3
MDM3051S -DGP-DAP - 4

MDM3051S Intelligent PressureTransmitterLong-term stability Range Code Power effect ±0.001% /10V (12V-42V DC), negligible. Pressure range limit The pressure is adjustable within the upper and lower limit. It is recommended to choose the range code with the lowest pressure range proportion to optimize the performance specification. MICRO SENSOR CO.,LTD - 4 - http://www.microsensor.cn Address: No.18 Yingda Rd, Baoji, Shaan Xi, China, 721006 Tel: +86 0917 3600739/3600832 Fax: +86 917 3609977

Open the catalog to page 4
MDM3051S -DGP-DAP - 5

MDM3051S Intelligent PressureTransmitter Zero setting The zero and pressure range could be adjust to any value within the measured rang in the table, only the calibrated range>Min. Range is valid. Mounting position effect The change of mounting position parallel to diaphragm could not influence the zero drift. If the angle between mounting position and diaphragm is over 90° , the zero drift is <0.4kPa which could be calibrated by zero setting. No effect on pressure range. Output 2- wire, 4mA~20mA DC, HART communication protocol, linearity or square root output optional. Output signal limit:...

Open the catalog to page 5
MDM3051S -DGP-DAP - 6

MDM3051S Intelligent PressureTransmitter Pressure range Address: No.18 Yingda Rd, Baoji, Shaan Xi, China, 721006 Tel: +86 0917 3600739/3600832 Fax: +86 917 3609977 EMC Please refer to next page “EMC table” 3 Installation Power and load condition Power supply: 24V DC, R<(Us-12V)/Imax (kQ) Imax=23mA Max. Voltage supply: 42V DC Min. Voltage supply: 12V DC, 15V DC(Backlit LCD display) Digital communication load resistance range: 230Q~600Q Electric Connection M20*1.5 cable sealing buckle, terminals are suitable for (0.5~2.5)mm2 wire. Process connection NPT 1/4 and UNF 7/16" female at both...

Open the catalog to page 6
MDM3051S -DGP-DAP - 7

MDM3051S Intelligent PressureTransmitter Nameplate: Stainless steel 304 Weight 3.3kg(not including LCD display, mounting support and process connection) Housing protection IP67 Note: (1) A degree: performance is normal within the technical standard range during testing. (2) B degree: During testing, the function or performance is lowered or lost temporarily, but it could be recovered by itself. Actual operation state, storage and data will keep the same. Outline Dimension Horizontal Piping Installation (front view) MICRO SENSOR CO.,LTD Horizontal Piping Installation (side view)...

Open the catalog to page 7
MDM3051S -DGP-DAP - 8

MDM3051S Intelligent PressureTransmitter 5 Electric connection chart Internal grounding External grounding Shortcut interface Testing terminal Note: the function of shortcut interface is equal to signal terminal. MICRO SENSOR CO.,LTD http://www.microsensor.cn Address: No.18 Yingda Rd, Baoji, Shaan Xi, China, 721006 Tel: +86 0917 3600739/3600832 Fax: +86 917 3609977

Open the catalog to page 8
MDM3051S -DGP-DAP - 9

MDM3051S Intelligent PressureTransmitter6 Process connection instruction 7.Basic error micro differential pressure range A. . range is - 100 pa ~ 199 pa, the basic error of plus or minus 1%; B. range is - 200 pa ~ 499 pa, the basic error of plus or minus 0.5%; C. range is - 500 pa ~ 999 pa, the basic error of plus or minus 0.2%; D. range is 1000 pa range (i.e., 1 kpa) or more, the basic error of plus or minus 0.075%. 7 Model and Specification Code Table MICRO SENSOR CO.,LTD Address: No.18 Yingda Rd, Baoji, Shaan Xi, China, 721006 Tel: +86 0917 3600739/3600832 Fax: +86 917 3609977

Open the catalog to page 9
MDM3051S -DGP-DAP - 10

MDM3051S Intelligent PressureTransmitter Code A C Code Others Exd version with E Explosion-proof cable MDM3051S-DGP H 1C A N N N 1 N N The whole spec MICRO SENSOR CO.,LTD Address: No.18 Yingda Rd, Baoji, Shaan Xi, China, 721006 Tel: +86 0917 3600739/3600832 Fax: +86 917 3609977

Open the catalog to page 10