Catalog excerpts
Earth1006 Remote Monitoring Terminal (V2.1) Features • IP68 protection, dust-proof and water-proof; • Multiple power supply options are available; • Wireless transmission, no field wiring; • Wide range measurement, pressure, temperature, level, flow, image, drain well cover etc.; • Muti-channel, max. 8-way sensor parameters access; • Remote setting for collection, transmission and image interval; • Sensor available with upper and lower limit of threshold value and web real-time warning; • PC and mobile terminal data application; • Support customer self-built system and configuration application; • Provide mounting accessories; • Solution for underground well. Introduction Earth1006 Remote Monitoring Terminal is a compact device with battery supply, ultra-low power consumption, IP68 protection, wireless communication and various sensor data collection function,in specific circumstance, multiple power supply options are available. It is suitable for the monitoring fields without power supply condition and the harsh environment. It could realize the multi-function including data collection, storage, alarming and transmission for underground water, firefighting water, dam water, water supply and drainage pipeline. With a wide coverage of wireless network, the product could detect the real-time data of many monitoring sites in a wide range of areas like tap-water pipeline pressure, flow, underground water, agricultural irrigation, dam level, water monitoring, wind, rain, ambient temperature and humidity, air quality monitoring, water flow monitoring, image and firefighting pipeline monitoring, especially suitable for Underground Well detection application in a harsh environment.
Open the catalog to page 1Earth1006 Remote Monitoring Terminal (V2.1) Interface Parameters Wake-up mode: magnetic activation/ timing/ alarm wake-up Collection interval: 1,5,10,30,60,360,720,1440 minutes optional Transmission interval: 1,5,10,30,60,360,720,1440 minutes optional Image interval: 30,60,720,1440 minutes optional Upload information: sensor data, battery information, network status, self check information Data Storage Local storage, Flash 4 MB (more than 200,000 history storage space) Configuration MICRO SENSOR CO.,LTD
Open the catalog to page 2Earth1006 Remote Monitoring Terminal (V2.1) Configuration mode: local/remote Environmental Conditions Operation temp.: -20°C~70°C Storage temp.: -40°C~85°C Display Segment LCD with backlight — Device Status — Unit — Channel Value/Alarm Status Other Specifications Protection: IP68 Housing: PA6+30% GF Installation method: hoop and wall mounting Outline dimension: 147 X 262.5 X 105.5mm Weight: about 2.3kg Accessories: fixed support*! magnetic bar*1, M5 bolt*1, $8mm expansion bolt*3, $200mm hoop*2 System Topology MICRO SENSOR CO.,LTD. Above sensors can be used together with Earth 1006. It...
Open the catalog to page 3Earth1006 Remote Monitoring Terminal (V2.1) Installation Method Earth1006 Remote Monitoring Terminal uses hoop and wall-mounting method which are easy for installation and convenient for maintenance and we also provide installation accessories. Underground Well Applications Level Well Cover MICRO SENSOR CO.,LTD
Open the catalog to page 4Earth1006 Remote Monitoring Terminal (V2.1) Solar Panel Dimension Order Guide Earth1006 Remote Monitoring Terminal Code Communication mode GA Multi-Bands in North America GS Multi-Bands in South America/Australia/New Zealand/Taiwan L3 LoRa[433MHz](select Earth1004 LoRa wireless router) L7 LoRa[470MHz](select Earth1004 LoRa wireless router) L8 LoRa[868MHz](select Earth1004 LoRa wireless router) L9 LoRa[915MHz](select Earth 1004 LoRa wireless router) Code Antenna type A2 External suction antenna(Antenna length 3 m) Code Power supply MICRO SENSOR CO.,LTD
Open the catalog to page 5Earth1006 Remote Monitoring Terminal (V2.1) Code SIM card S2 LoRa without card 1. Matching sensors are not included in this datasheet. Please purchase them separately. 2. The communication protocol is needed if users choose RS485 interface product. 3. If the user has special requirement, please feel free to contact our company. MICRO SENSOR CO.,LTD
Open the catalog to page 6All Micro Sensor Co. catalogs and technical brochures
-
MPM4700 Level Transmitter
5 Pages
-
MPM380 pressure transducer
3 Pages
-
MPM483 pressure transmitter
6 Pages
-
MPM480 pressure transmitter
6 Pages
-
MS-H375 Hand Communicator
2 Pages
-
tri-valve
2 Pages
-
MPM285 Pressure Sensor
4 Pages
-
MPM286 Pressure Sensor
4 Pages
-
MPM161 PressureSensor
4 Pages
-
MPM162 Pressure Sensor
3 Pages
-
MPM489WZ1
3 Pages
-
MPM489WZ4 Level Transmitter
3 Pages
-
MPM7847 Pressure Sensor
3 Pages
-
MPM7848 Pressure Sensor
3 Pages
-
MPM7858 Pressure Sensor
3 Pages
-
MPM7867 Pressure Sensor
4 Pages
-
MPM7868 Pressure Sensor
3 Pages
-
MPM7878 Digital Pressure Sensor
29 Pages
-
MPM7888 Digital Pressure Sensor
25 Pages
-
Temperature Switch MTM5881
4 Pages
-
MPM4889 Pressure Transmitter
3 Pages
-
MPM8320 Pressure Transmitter
3 Pages
-
MPM4809TD Level Transmitter
6 Pages
-
MPM4893 Pressure Transmitter
2 Pages
-
MPM4893W Level Transmitter
2 Pages
-
MPM4511 Pressure Transmitter
3 Pages
-
WZP(K) Temperature Sensor
3 Pages
-
M1500 Air Sampling Pump
2 Pages
-
MTM5581 Temperature Switch
4 Pages
-
MPM416W/WK/WRK
7 Pages
-
MPM6861G
4 Pages
-
M1500
2 Pages
-
MFK5081 Flow Switch
4 Pages
-
MFM500 Flow Switch
4 Pages
-
MFE600
24 Pages
-
MPM160 Pressure Sensor
5 Pages
-
mpm426ws level transmitter
3 Pages
-
MPM287 Pressure Sensor
3 Pages
-
MPM288 Pressure Sensor
3 Pages
-
MPM281VC pressure sensor
3 Pages
-
MFM500A Flow Switch
4 Pages
-
MPM484C
3 Pages
-
MS—H375 Hand Communicator
2 Pages
-
MPM4811 Level Transmitter
3 Pages
-
MPM460 MPM460 Pre
5 Pages
-
MPM380 MPM380 Pre
3 Pages
-
MPM4760 MPM4760 Di
4 Pages
-
MFM500 MFM500 Flo
4 Pages
-
LB800 LB800 Seri
3 Pages
-
1151 1151 Tri-v
2 Pages
-
PD140 PD140 Ligh
2 Pages
-
Pressure Switch MPM/MDM580
5 Pages
-
Pressure Switch MPM583
3 Pages
-
Pressure Switch MPM582
3 Pages
-
Pressure Switch MPM5581
7 Pages
-
Flow Switch
4 Pages
-
Appendix LB800
3 Pages
-
Appendix 1151
2 Pages
-
Appendix Cut-off Valve
1 Pages
-
Appendix MS-H376
2 Pages
-
Appendix MS-H376
2 Pages
-
Appendix PD140
2 Pages
-
Appendix MS200
1 Pages
-
OEM Pressure Sensor MPM281
4 Pages
-
OEM Pressure Sensor MPM280
6 Pages
Archived catalogs
-
mdm3051s_DP
13 Pages
-
MPM5881 Pressure Switch
5 Pages
-
MDM3051S -GP-AP
12 Pages
-
MDM3051S -DGP-DAP
10 Pages
-
MPM489B
3 Pages
-
MPM4891 Pressure Transmitter
2 Pages
-
MPM4780 Pressure Transmitter
4 Pages