Catalog excerpts
NDIR evaluation kit Manual for evaluation of IR emitters and detectors NDIR evaluation kit available at Micro-Hybrid-Shop Micro-Hybrid Electronic GmbH Heinrich-Hertz-Str. 8 07629 Hermsdorf | Germany MANUAL › NDIR evaluation kit | © Micro-Hybrid Electronic GmbH | 2023-03 | All rights reserved.
Open the catalog to page 1Manual › NDIR evaluation kit Content 1. General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. Content and features overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembly instruction for NDIR evaluation kit . . . . . . . . . . . . . . . . . . . . . . 4.2 Concept of emitter control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4 Possible power levels in dependece of the source resistance . . . . . .
Open the catalog to page 2Manual › NDIR evaluation kit 1. General description The kit is designed for thermopile or pyroelectric detectors and IR sources from Micro-Hybrid Electronic GmbH. It is an easy way to evaluate these parts and get started in NDIR gas analysis without developing an electrical circuit and software. The system is flexible, making it possible to optimize the operating parameters for the specific application. This flexibility includes easy control of the IR source and the reading & monitoring of the output data from the detectors. Thus, the development process is accelerated dramatically with...
Open the catalog to page 3Manual › NDIR evaluation kit 3. Getting started 3.1 Installing an emitter ■ 1st way using the enclosed cable and socket Please connect the both insulated pins from the emitter with the brass pins of the connector
Open the catalog to page 4Manual › NDIR evaluation kit Solder pin matrix referring to detector type Setting main board jumpers referring to detector type Setup detector in matrix board, consider pinout pin 1 of detector to pin 1 of matrix board 3.3 Assembly instruction for NDIR evaluation kit ■ Install the emitter shown in chapter 3.1. Set the jumper for the power adjustment on the source board to digital potentiometer Install the detector to the uni-socket board shown in 3.2 Connect the uni-socket board to the detector board Set the jumpers according to the application and detectors 3.2 Install the measurement cell...
Open the catalog to page 5Manual › NDIR evaluation kit 3.4 Installing the software For correct installation, please follow ensuring steps: 1. Disconnect Evaluation board from PC 2. Open path Software Evaboard 1.74 on USB-Stick 3. Run CDM v2.10.00 WHQL Certified.exe 4. Run setup.exe 5. Follow the instructions to install software and drivers 6. Restart your computer and start Evaluation kit Software 7. Connect Evaluation board to PC – USB Driver should be installed automatically For technical requests or general questions please contact us: T +49 36601 592-100 sales@microhybrid.com Make sure Evaluation kit board is...
Open the catalog to page 6Manual › NDIR evaluation kit 4. Source board 4.1 Jumpers and connecters in case of connecting with detector-evaluation-board (set the emitter-power by the software)
Open the catalog to page 7Manual › NDIR evaluation kit 4.2 Concept of emitter control Current measurement with shunt resistance DC-DC Converter Emitter Power monitor Feedback voltage Supply voltage Current consumption Reference voltage Emitter resistance Operating temerature Frequency range Power consumption Output power accuracy adjustable defined by jumper (FB) or potentiometer
Open the catalog to page 8Manual › NDIR evaluation kit 4.4 Possible power levels in dependence of source resistance 5. Detector board 5.1 Jumpers and connecters ■ Connected supply voltage Connected USB-port
Open the catalog to page 9Manual › NDIR evaluation kit Thermistor Input selectable bandpass selectable bandpass Channel 4 Reference Voltage Offset compensation Offset compensation Supply voltage Current consumption Amplification Reference voltage Operating temerature Pyrodetector Thermopile Detector supply Signal aquisition* Pyrodetector Thermopile 5.4 Data interface The Evaluation kit comes with an USB interface for the data transfer between the PC and the equipped microcontroller. The USB controller generates a virtual COM port with a default baud rate of 115 200 bit/s. For data transfer, use the 8-N-1 parameter...
Open the catalog to page 10Manual › NDIR evaluation kit 6. Visualization software Graphical user interface Provides functions for signal conditioning via digital potentiometers. Is used to specify if the gain is set to thermopile or pyro by the jumper 4/5. Selectable values 1 - 255. Determines the gain of the second amplifier stage for both lines via digital potentiometer. The value below shows the current amplification. Selectable values 1 - 255. Value of the linear offset compensation in the second amplifier stage. The value below shows the step size in volt when changing the digital potentiometer by one digit....
Open the catalog to page 11Manual › NDIR evaluation kit Settings- and display elements for communication. Shows the current COM-port where the detector board was found. Shows the fill level of the receive buffer. Transmitting / receiving Indicates the state of communication Used to change the readout algorithm and measuring the signals. Read algorithm Determines the number of samples that will be read out. Periodic: Read out as many values as necessary to represent a defined number of periods. Time: Read out the values, which were received within a defined time. Periods / time Number of periods / length of the time...
Open the catalog to page 12All Micro-Hybrid Electronic GmbH catalogs and technical brochures
-
datasheet MTS2SENS200
6 Pages
-
Data sheet JSIR-350-5
6 Pages
-
data sheet MPS2SENS
6 Pages
-
datasheet NDIR bundles
6 Pages
-
datasheet MPS2SENS LiTa03
6 Pages
-
datasheet MPS2SENS LiTa03
6 Pages
-
datasheet NDIR bundles
6 Pages
-
datasheet MicroSens 140-HS
3 Pages
-
datasheet MTS1TEMP
6 Pages
-
datasheet MTS1TEMP80
6 Pages
-
data sheet MTS1TEMP44
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS4SENS
6 Pages
-
datasheet MTS4SENS
6 Pages
-
datasheet MTS4SENS
6 Pages
-
datasheet MTS4SENS
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MicroSENS 180-HS
3 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
Data sheet MTS2SENS
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
Micro-Hybrid company brochure
14 Pages
-
datasheet MTS4SENS200
6 Pages
-
datasheet MTS4SENS200
6 Pages
-
datasheet MTS4SENS200
6 Pages
-
datasheet MTS4SENS200
6 Pages
-
datasheet MTS4SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
Data sheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet MTS2SENS200
6 Pages
-
datasheet JSIR-350-4
6 Pages
-
data sheet MTS1TEMP56
6 Pages
-
data sheet NDIR bundles
6 Pages
-
Manual CoriSENS
11 Pages
-
datasheet NDIR bundles
6 Pages
-
datasheet NDIR bundles
6 Pages
-
Data sheet JSIR-340-4
6 Pages
-
Data sheet JSIR-340-5
6 Pages
-
Data sheet AccTRANS
9 Pages
-
data sheet MPS4SENS
6 Pages
-
Data Sheet AccTRANS
9 Pages
-
datasheet MPS2SENS
6 Pages
-
datasheet MPS2SENS
6 Pages
-
datasheet MPS2SENS
6 Pages
-
data sheet MPS4SENS
6 Pages
-
datasheet MPS2SENS
6 Pages
-
datasheet MPS2SENS
6 Pages
-
data sheet MPS2SENS
6 Pages
-
datasheet MPS2SENS
6 Pages
-
datasheet MPS2SENS
6 Pages