Data sheet AccTRANS
9Pages

{{requestButtons}}

Catalog excerpts

Data sheet  AccTRANS - 1

AccTRANS Manual Analog acceleration sensor to measure oscillation and vibration on train bogies AccTRANS available at Micro-Hybrid-Shop Filter products simply by selecting the desired properties and request your quotation. Micro-Sensor GmbH Heinrich-Hertz-Str. 8 07629 Hermsdorf | Germany MANUAL › AccTRANS | © Micro-Sensor GmbH | 2022-08

Open the catalog to page 1
Data sheet  AccTRANS - 2

Manual › AccTRANS Content 1. Technical parameters 2. Functional block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. Current output connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Root mean square Micro-electromechanical system Meantime between failures Radio frequency

Open the catalog to page 2
Data sheet  AccTRANS - 3

Manual › AccTRANS 1. Technical parameters Physical parameter Sensitive axis Unit y-direction (additional x on request) Sensitivity error In-band tolerance Damping gradient Current output Zero signal Burden (current output) Applied standard Operating temperature range Extended operating temperature at start-up Vibration & shock test Altitude class Humidity class Pollution degree All specifications at +25 °C, unless otherwise defined. 1 customizable 2 dependent on measurement range Electrical parameters Supply voltage Supply current Class of power supply interruption

Open the catalog to page 3
Data sheet  AccTRANS - 4

Manual › AccTRANS 2. Functional block diagram MEMS accelerometer Band - pass filter (> 24 dB/octave) Voltage to current converter Isolated power supply 3. Output characteristics Output current Output signal Output current Band pass filter characteristics 10 Filter characterisitcs Type and frequency range

Open the catalog to page 4
Data sheet  AccTRANS - 5

Manual › AccTRANS 4. Current output connection ■ Current measurement device with load resistance of max. 200 Ω Pin A The shield is not connected to the housing of the sensor. Connect the housing to train earth potential. Train earth potential Supply Supply GND Signal 4 - 20 mA Signal GND Supply Supply GND Signal 4 - 20 mA Signal GND Current direction Earth potential Train Supply voltage Supply ground Signal output y-axis Signal ground y-axis

Open the catalog to page 5
Data sheet  AccTRANS - 6

Manual › AccTRANS 7. Mechanical dimensions Weight including 3 meters cable: ~ 1.3 kg

Open the catalog to page 6
Data sheet  AccTRANS - 7

Manual › AccTRANS 9. RAMS properties MTBF 1 Failure rate calculated as the total sum of the failure rates of each component, with respect to operating temperature conditions. 10. Handling instructions 10.1. Assembly The accelerometer AccTRANS is supposed to be mounted in the vicinity of the wheel axles in the outskirt area of the train. The housing of the sensor is designed as a flange with four holes for M5 screws (see subsequent drawing). Ground connection screw hole, threaded (M5) Hole for mounting screws / bolts Mounting on given M4 thread rods Mounting with M4 bolts Align the device by...

Open the catalog to page 7
Data sheet  AccTRANS - 8

Manual › AccTRANS 10.2. Maintenance The device is developed in a way that no maintenance actions are required during its lifetime. 10.3. Disassembly 1. Disconnect the sensor’s cable from the train’s connector. 2. Unscrew bolt in grounding screw hole and remove grounding cable. 3. Loosen either the four bolts or the nuts with which the device has been attached and lift off the sensor. 11. Troubleshooting Basically two kinds of errors can occur, electrical and mechanical ones. One cause of a remediable mechanical error could be improper connection of the sensor, e.g. by contaminated connector...

Open the catalog to page 8
Data sheet  AccTRANS - 9

Manual › AccTRANS 12. Applied standards Applied standards according to DIN EN 50155 DIN EN 55011 Conducted emission Radiated emission electromagnetic field Immunity to electromagnetic field Immunity to electrical fast transient/burst Immunity to electrical slow transient/surge Immunity to conducted RF voltage Overvoltage at power supplies Shock and vibration tests Damp heat, cyclic (2 x 24h cycle) Cold test Fire protection on railway vehicles Other standards RoHS, REACH 13. Product key AccTRANS ### V# Supply voltage: Measurement range: Further options on request. Disclaimer All rights...

Open the catalog to page 9