video corpo

Optical precision micrometers
20Pages

{{requestButtons}}

Catalog excerpts

Optical precision micrometers - 1

More Precision optoCONTROL // Optical precision micrometers

Open the catalog to page 1
Optical precision micrometers - 2

Optical micrometers for high precision applications High accuracy and measuring rate Resolution from 0.1μm Measurement objects from 0.02mm Wear-free measurement for long service life Different models for numerous application areas Optical precision micrometers Micrometers from Micro-Epsilon operate according to the ThruBeam principle. Here, the transmitter produces a parallel light curtain that is transmitted via a lens arrangement into the receiving unit. The beam is interrupted if there is an object in the light path. The shadowing generated by this object is recorded by the receiving...

Open the catalog to page 2
Optical precision micrometers - 3

Measuring ranges Measurement mode optoCONTROL 1200 Compact, fast and space-saving 90° version; integrated controller optoCONTROL 1202 Target-sensor gap up to 2000mm; integrated controller / resolution 8μm optoCONTROL 1220 Target-sensor gap up to 2000mm; integrated controller / resolution 2μm optoCONTROL 2500 High accuracy and stability / resolution 1μm; target-sensor gap up to 700mm (optional 1850mm) optoCONTROL 2520 Compact design with integrated controller; target-sensor gap up to 2000mm / resolution 1µm optoCONTROL 2600 Maximum accuracy and stability; target-sensor gap up to 400mm;...

Open the catalog to page 3
Optical precision micrometers - 4

Compact laser micrometers with high measuring rate Measuring range 2 - 30mm Resolution ≥10µm Measuring rate up to 100kHz (-3dB) Analogue output 0 ...10VDC Laser class 1 High quality glass lense optics obust and compact design with R integrated controller Limit switch with up to 60kHz switching frequency Axial and radial design Measurement mode The distance is adjustable from 20mm to Measuring rate maximum 5m (no calibration required) (frequency response) 100kHz (-3dB) Measuring principle The optoCONTROL 1200 is based on the principle of light quantity measurement. The light of a red laser...

Open the catalog to page 4
Optical precision micrometers - 5

Measuring range Distance light source - receiver (free space) Measuring rate (frequency response) Light source semiconductor laser <0.39mW, 670nm (red, laser class 1) Permissble ambient light Analogue output Temperature drift of the analogue output Switching output PNP dark switching and NPN bright switching (max. switching frequency 60kHz) adjustable signal threshold Operation temperature Switching state and dusty optics Storage temperature Operation voltage 12-32VDC, reverse polarity protection straight up Mounting holes light source Weight (without cable) Protection class FSO = Full...

Open the catalog to page 5
Optical precision micrometers - 6

Digital micrometers with extended measuring range Measuring ranges 75 and 98mm Resolution≥8µm Measuring rate up to 400Hz Serial interface RS232 Laser class 1 igh resolution CCD array detector with integrated H controller Sub-pixel evaluation Measuring distance selectable from 20 to 2000mm Integrated polarisation filter / interference filter 2 digital inputs 3 digital outputs (limit switch) ODC1202-Tool software included Measuring principle The laser beam for the optoCONTROL 1202 laser micrometers is output from the optical transmitter as a parallel aimed laser beam. The laser line strikes a...

Open the catalog to page 6
Optical precision micrometers - 7

Measuring range Distance light source - receiver Measuring rate Measurement values via RS232, parameterizable under Windows using the ODC-1202 tool (included in scope of supply) Semiconductor laser, 670nm, DC-operation, ≤0,39mW max opt. power, laser class 1 4), the use of these laser sensors therefore requires no additional protective measures Laser Permissible external light Optical filter interference filter, red light filter RG630, polarization filter Housing material aluminium, anodised in black 8-pin female connector type binder series 712 (SPS/Power); 4-pin female connector type...

Open the catalog to page 7
Optical precision micrometers - 8

Optical online micrometer Measuring range 28mm Resolution typ. 2µm Repeatibility typ. ±4µm Serial interface RS232 Laser class 1 isible laser line (red light 670nm) V orking distance of up to 2,000mm W ntegrated interference filter I CD line detector with 2,048 pixels, C 16,384 sub-pixels (8-fold) digital inputs, 2 digital outputs 2 obust aluminium housing suitable for R industrial use Measuring principle The laser beam for the optoCONTROL 1220 laser micrometers is output from the optical transmitter as a parallel aimed laser beam. The laser line strikes a CCD array in the receiving optical...

Open the catalog to page 8
Optical precision micrometers - 9

Measuring range Distance light source - receiver Measuring rate Measurement values via RS232, parametrizable under Windows using the ODC1202 tool (included in scope of supply) semiconductor laser, 670nm, DC-operation, ≤0.39mW max. opt. power, laser class 1 3) the use of these laser sensors therefore requires no additional protective measures Laser Optical filter interference filter, RG645; polarisation filter Housing material aluminium, anodised in black 8-pin female connector type binder series 712 (SPS/Power); 4-pin M5 female connector type binder series 707 (RS232/PC) 4-pin female...

Open the catalog to page 9
Optical precision micrometers - 10

High precision laser micrometer Measuring range 34mm Resolution 1µm Measuring rate 2.3kHz Linearity ±10µm Serial interface RS232/RS422 Laser class 1 igh resolution and precision H easuring rate 2.3kHz for fast processes M Laser-ThruBeam technology ix different measuring programs S ree parameterisation and data acquisition tool F Predefined measurement modes (six individual programs can be selected) Segment Two-Segment Measuring principle optoCONTROL 2500 is a laser-based measuring system with integrated high resolution CCD camera. The Thru-Beam micrometer measures the dimension of an object...

Open the catalog to page 10
Optical precision micrometers - 11

Measuring range Smallest diameter or gap (detectable target) Distance light source - CCD-camera Distance (target to receiver) Measuring rate Light source Semiconductor laser 670nm, class 1 Analogue output Digital output Switching output 1 x error, 2 x limit, 2 x warning; LC-display, 3 x LED; Sync-Out Sync-In; zero; Laser On/Off Operation temperature Storage temperature Power supply Cable length 2m (option: extension 3m / 8m) receiver / light source Protection class IP 40 LCD-display (value, maximum, minimum, peak-to-peak)) display in mm or inch, selectable; menu languages in german /...

Open the catalog to page 11