cad

SPECTRA-PHYSICS 337-i AIR-COOLED NITROGEN LASER SYSTEM
2Pages

{{requestButtons}}

Catalog excerpts

SPECTRA-PHYSICS 337-i AIR-COOLED NITROGEN LASER SYSTEM - 1

12/2002 • PART NUMBER 0456-2680, REV. A SPECTRA-PHYSICS 337-i AIR-COOLED NITROGEN LASER SYSTEM ® INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM CLASS 3b LASER PRODUCT Wavelength: 337 nm Maximum Average Output Power: 6 mW Maximum Output Power per Pulse: 400 ìJ Spectra-Physics 1335 Terra Bella Avenue Mountain View, CA 94043 Tel: 1-800-775-5273 Tel: 1-(650) 961-2550 Fax: 1-(650) 964-3584 e-mail: sales@splasers.com http://www.splasers.com Australia: (61) 8-8443-8668 Belgium: (31) 40 265 99 59 China: (86) 10 6256 2934 France: (33) 1 6918 63 11 Germany: (49) 6151-708300 Hong Kong: (852) 2523-5688 India: (91) 80 6763 465 Israel: (972) 3-6356650 Italy: (39) 02-57465-1 Japan: Tokyo (81) 3-3794-5511 Osaka (81) 6-6941-7331 Netherlands: (31) 40 265 99 59 S. Korea: (82) 2-587-8727 Spain: (34) 91-3775006 Scandinavia: (46) 8-550 10403 Taiwan: (886) 3-426-2376 UK: (44) 1442-258100 Other European Countries: (49) 6151-7080 Other Pacific Countries: 1-650-961-2550 Services and Equipment Air Flow Requirements Environmental Electric Service Requirements Temperature Range 4 – 40°C (40 – 105°F) Humidity (noncondensing) 0 – 95% Voltage +24 Vdc None Current 3 A peak 1 A average at 20 Hz Altitude 0 – 3000 m (0 – 9800 ft) Optical Characteristics Wavelength 337.1 nm Repetition Rate Spectral Bandwidth 1 to 20 Hz, user-supplied trigger 0.1 nm Pulse Width, FWHM 4 ns Pulse Energy 150 ìJ Pulse to Pulse Energy Stability 3% std. dev. at 10 Hz Peak Power 36 kW Average Power 3 mW at 20 Hz Beam Size 3 x 7 mm Beam Divergence, Full Angle 3 x 8 mrad Power Consumption 24 W at 20 Hz Electrical Characteristics External Trigger TTL, Optoisolated Trigger In to Optical Pulse Out < 700 ns; < 20 ns std. dev. jitter Ordering Information 337-i Standard P/N 337999-01 Features and Benefits: Modular design No alignment required Quiet Variable pulse rate Patented sealed plasma cartridge Field-replaceable plasma cartridge Power on demand Externally triggered Low EMI Applications: MALDI-TOF mass spectrometry Laser-induced fluorescence Cell ablation Medical diagnostics Materials research

Open the catalog to page 1
SPECTRA-PHYSICS 337-i AIR-COOLED NITROGEN LASER SYSTEM - 2

SPECTRA-PHYSICS 337-i AIR-COOLED NITROGEN LASER SYSTEM The 337-i nitrogen laser emits 4 ns pulses in the UV at 337 nm. The pulse repetition rate may be varied from 1 to 20 Hz with a pulse energy of up to 150 ìJ. The laser is externally triggered by a TTL-level pulse for synchronization with other timed events. Constant pulse shape and good pulse-to-pulse stability were designed into the 337-i with our fixed-electrode and discharge-stabilizing pre-ionizers. The 337-i features our user-replaceable plasma cartridge, allowing the customer to regain the performance of a new laser at a fraction...

Open the catalog to page 2

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1 Pages

  2. M-401

    1 Pages

  3. newport ressource

    1640 Pages

  4. Motion PL30

    24 Pages

  5. Beamsplitters

    34 Pages

  6. Base Clamps

    1 Pages

  7. Rod Clamps

    1 Pages

  8. V-Blocks

    1 Pages

  9. Blackbodies

    2 Pages

  10. Beam Dump

    1 Pages