cad

Pencil Style Calibration Lamps
3Pages

{{requestButtons}}

Catalog excerpts

Pencil Style Calibration Lamps - 1

75 Email: sales@newport.com • Web: newport.com L i g h t S o u r c e s TECHNICAL REFERENCE CALIBRATION SOURCES DEUTERIUM SOURCES ARC SOURCES INCANDESCENT SOURCES MONOCHROMATOR AND FIBER ILLUMINATORS SOLAR SIMULATORS PHOTOLITHOGRAPHY INSTRUMENTS ACCESSORIES FOR ORIEL LIGHT SOURCES Oriel Pencil Style Calibration Lamps 6035 Hg(Ar) Lamp in 6058 Fiber Optic Accessory. These calibration lamps produce narrow, intense lines from the excitation of various rare gases and metal vapors. They are used for wavelength calibration of spectroscopic instruments such as monochromators, spectrographs, and spectral radiometers. We offer six lamps; choose the lamp or lamps that suit your wavelength range, using Table 1 as a guide. We offer AC and DC power supplies to run these lamps. If output variations are not a concern, and you are only operating one or two line lamps, choose an AC supply. If you are calibrating multichannel detectors or if you are using various lamps, the DC supply is a better choice (the DC supply runs any of the line lamps). We also offer the following accessories: • Spectral Calibration Lamp Mounts These hold one or two calibration lamps at the input slit of an Oriel Monochromator or Spectrograph. • Fiber Optic Accessory The 6058 Accessory holds the face of an SMA terminated fiber close to the lamp, to collect a portion of the light output for spectral calibration purposes. • Rod Mounted Lamp Holder If you want to hold the lamp in open air, use the 63670 Holder. It holds the lamp atop an optical rod. • Booklet of Spectra The 6052 is a booklet of typical spectra of these lamps. • Filters We offer filters that fit over the lamp to block a specific wavelength region (see Fig. 1) • Aperture Shields These fit over the lamps to limit the radiation area. 200 300 400 500 600 700 800 x 104 WAVELENGTH (nm) 0.2 0.1 0 2 1 0 4 2 0 2 1 0 RELATIVE INTENSITY (a (b (d (c 6035 Hg(Ar) LAMP WITH NO FILTER 6035 Hg(Ar) LAMP WITH 6041 FILTER 6035 Hg(Ar) LAMP WITH 6042 FILTER 6035 Hg(Ar) LAMP WITH 6057 FILTER Fig. 1 Relative line intensities of 6035 Lamp with different filters. WAVELENGTH (nm) 600 800 1000 1200 1400 1600 1800 0.0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 RELATIVE UNITS Fig. 2 Output spectrum of 6033 Xenon Lamp, run at 6 mA, measured with MIR8025 FT-IR with CaF2 beam splitter and InGaAs Detector. • Compact and simple tools for calibrating spectral instruments • Narrow, discrete UV to IR wavelengths • Excellent stability

Open the catalog to page 1
Pencil Style Calibration Lamps - 3

77 Email: sales@newport.com • Web: newport.com L i g h t S o u r c e s TECHNICAL REFERENCE CALIBRATION SOURCES DEUTERIUM SOURCES ARC SOURCES INCANDESCENT SOURCES MONOCHROMATOR AND FIBER ILLUMINATORS SOLAR SIMULATORS PHOTOLITHOGRAPHY INSTRUMENTS ACCESSORIES FOR ORIEL LIGHT SOURCES WAVELENGTH (nm) 200 250 300 350 400 450 500 550 600 RELATIVE UNITS 0.0 1.0 0.8 0.6 0.4 0.2 Fig. 4 Output spectrum of 6035 Hg(Ar) Lamp, run at 18 mA, measured with MS257 1/4 m Monochromator with 50 ìm slits. Power Supplies Type For These Lamps Output Current* (mA) 110 V, 60 Hz Model 220 V, 50 Hz Model AC Hg(Ar),...

Open the catalog to page 3

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1 Pages

  2. M-401

    1 Pages

  3. newport ressource

    1640 Pages

  4. Motion PL30

    24 Pages

  5. Beamsplitters

    34 Pages

  6. Base Clamps

    1 Pages

  7. Rod Clamps

    1 Pages

  8. V-Blocks

    1 Pages

  9. Blackbodies

    2 Pages

  10. Beam Dump

    1 Pages