Overview: The document provides detailed information about the Oriel MS127i 1/8 m Imaging Spectrograph, a versatile and efficient single grating imaging spectrograph designed for applications not requiring broad spectral range coverage or high-end resolution.
Optical Configuration: The MS127i utilizes a Czerny-Turner optical layout with an astigmatism correcting mirror, allowing high spectral and spatial resolution at a low F/# of F/3.8. This configuration minimizes stray and re-diffracted light.
Multi-track Spectroscopy: The spectrograph is designed to economically correct astigmatism, allowing for the separation of multiple tracks using a CCD, such as InstaSpec™ CCDs, making it suitable for double beam spectroscopy.
Built-in Shutter: A normally closed shutter behind the input slit blocks light effectively, with a minimum opening time of 0.2 seconds and operational rates up to 0.5 Hz.
Interchangeable Gratings: The MS127i supports a variety of interchangeable gratings, allowing users to select based on their spectral range of interest. Gratings can be changed without realigning the instrument.
Specifications: Key specifications include an input focal length of 127 mm, exit focal length of 138.5 mm, F/# of F/3.7, usable wavelength range from 180 nm to 25 µm, and a resolution of 0.22 nm with a 1200 l/mm grating.
Mounting and Dimensions: The spectrograph can be mounted using 1/4-20 tapped holes or placed on a flat surface. It is designed to support a detector without hard mounting.
Ordering Information: To order the MS127i, a grating and slit must be ordered separately. The document lists various models of gratings and fixed slits with their specifications.
Table Summary: The document includes a table listing different gratings for the MS127i, detailing line density, blaze wavelength, grating type, primary wavelength range, and efficiency. Another table provides specifications for fixed slits, including slit width, height, and resolution.
See more

Catalog excerpts

Oriel MS127i™ 1/8 m Imaging Spectrograph  -1

1212 MONOCHROMATORS AND SPECTROGRAPHS BENCHTOP SPECTROMETERS MINISPECTROMETERS SINGLE CHANNEL DETECTION SYSTEMS AND CCD CAMERAS FT-IR SPECTROMETERS Phone: 1-800-222-6440 • Fax: 1-949-253-1680 S p e c t r o s c o p y I n s t r u m e n t s ACCESSORIES FOR SPECTROSCOPY INSTRUMENTS Oriel MS127iTM 1/8 m Imaging Spectrograph 77480 MS127i 1/8 m Spectrograph with various slits The MS127i™ is a versatile, efficient, single grating, imaging spectrograph at an affordable price. For spectroscopy applications not covering a broad spectral range, and not requiring the resolution and imaging performance of our high end MS260iTM and MS257TM 14 m instruments, the MS127i is the right choice. For a specification comparison of all our spectrographs, refer to our overview on page 1208. Optical Configuration The MS127i has been designed for ultra low stray light and no re-diffracted light. It utilizes a Czerny-Turner optical layout with one significant modification - the addition of an astigmatism correcting mirror after the collimating mirror (see Fig. 1). This patented system allows high spectral and spatial resolution at a low F/#, F/3.8. GRATING INPUT SLIT ASTIGMATISM CORRECTING MIRROR FOCUSING MIRROR CCD DETECTOR FLAT MIRROR COLLIMATING CONCAVE MIRROR RED BLUE Fig. 1 Optical configuration of MS127i 1/4 m Spectrograph Multi-track Spectroscopy with MS127i Spectrograph Full correction for astigmatism in spectral instruments requires sophisticated toroidal mirrors (as in our MS257 1/4 m spectrograph); they allow vertical resolution of many tracks simultaneously. But, for many applications there is a need for only 2 to 3 tracks, as in double beam work. We designed the MS127i to correct astigmatism economically. You can reliably separate multiple tracks for Multi-track Spectroscopy with a CCD that has the ability to record individual tracks, such as our InstaSpec™ CCDs. Thus, MS127i makes the acquisition of double beam spectra of pulsed or continuous sources possible on a limited budget. Built-in Shutter A normally closed shutter located behind the input slit effectively blocks light from entering MS127i. The shutter circuitry is housed inside MS127i; shutter power is from a simple 5 V supply, provided. Minimum opening time is 0.2 s. This shutter will operate at rates to 0.5 Hz. Interchangeable Gratings We offer a large selection of interchangeable gratings for the MS127i. Choose the one that covers the spectral range of interest. The gratings are supported on a precision holder, which clips into the grating mount. They can be easily interchanged without the need to realign the instrument. Table 1 lists the specifications for each model. • Resolves multiple spectral tracks with excellent spatial separation • Built-in shutter for zero referencing and for multi-track applications • Low stray light, minimal rediffracted light • Easily changeable gratings for true versatility

 Open the catalog to page 1
Oriel MS127i™ 1/8 m Imaging Spectrograph  -2

S p e c t r o s c o p y I n s t r u m e n t s 1213 Email: [email protected] • Web: newport.com MONOCHROMATORS AND SPECTROGRAPHS SINGLE CHANNEL DETECTION SYSTEMS MINISPECTROMETERS BENCHTOP SPECTROMETERS AND CCD CAMERAS FT-IR SPECTROMETERS ACCESSORIES FOR SPECTROSCOPY INSTRUMENTS Line Density (I/mm) Blaze Wavelength Grating Type Wavelength Scale Conversion Factor Multichannel Array Bandpass (nm)* Spectral Resolution (nm)** Peak Efficiency (%) Primary Wavelength Region*** (nm) Instrument's Upper Mechanical Wavelength Limit (for specified grating) Model 3600 405 Holographic 0.33 46 0.06 60 180 -...

 Open the catalog to page 2

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1  Page

  2. M-401

    1  Page

  3. newport ressource

    1640  Pages

  4. Motion PL30

    24  Pages

  5. Nanopositioners

    40  Pages

  6. Beamsplitters

    34  Pages

  7. Optrical mirror

    33  Pages

  8. Motion System

    2  Pages

  9. Base Clamps

    1  Page

  10. Rod Clamps

    1  Page

  11. V-Blocks

    1  Page

  12. Blackbodies

    2  Pages

  13. Beam Dump

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.