cad

Oriel Mini Monochromator
3Pages

{{requestButtons}}

Catalog excerpts

Oriel Mini Monochromator - 1

1178 MONOCHROMATORS AND SPECTROGRAPHS BENCHTOP SPECTROMETERS MINISPECTROMETERS SINGLE CHANNEL DETECTION SYSTEMS AND CCD CAMERAS FT-IR SPECTROMETERS Phone: 1-800-222-6440 • Fax: 1-949-253-1680 S p e c t r o s c o p y I n s t r u m e n t s ACCESSORIES FOR SPECTROSCOPY INSTRUMENTS Oriel Mini Monochromator 78024 Mini Monochromator These new Monochromators are low cost, compact and simpleto- use instruments for moderate resolution applications. They are ideal for general laboratory experiments and educational studies covering fixed wavelength ranges and not requiring subnanometer resolutions. The focal length of these instruments is 74 mm; the F/# is 3.9. For demanding spectroscopy applications, please refer to our long focal length, high resolution bench-top instruments detailed on pages 1184 through 1196. Manual and Motorized Versions We offer two families of Mini Monochromators: Manual Monochromators These models have a knurled knob, which causes a precision lead screw/sine bar mechanism to rotate the grating. A digital counter displays the wavelength in nanometers, to 0.2 nm. Motorized Monochromators For scanning applications, we recommend that you choose a motorized monochromator. These instruments use a stepping motor driven by an external motor controller with RS 232 interface. Included with the controller is an application program with over 25 commands to control a variety of operations of the grating drive. These motorized models also include a manual drive and a digital counter that displays the wavelength to 0.2 nm. Fig. 1 Optical configuration of Mini Monochromator • Low cost, very compact instruments for general spectroscopy applications • 74 mm focal length, moderate resolution • Manual and stepping motor driven models • VIS - NIR (190 nm to 1.2 ìm) models • Optional VIS-NIR light source Optical Configuration Fig. 1 shows the Ebert-Fastie design of these monochromators. Full spectrum radiation is focused at the entrance slit and reflected by a folding mirror onto a spherical collimating/focusing mirror. This mirror collimates the radiation and directs it onto the grating, where it is diffracted. Once diffracted, the radiation is directed back to the collimating/focusing mirror, and a segment of the dispersed radiation is focused at the exit slit via a second folding mirror. Resolution The resolution of the instrument is a function of its focal length, the dispersion of the grating, the width of the entrance and exit slits, and to a lesser degree, wavelength. As standard models, these instruments include two 300 ìm x 4 mm slits. You can increase the resolution by using narrower slits. Request different slits at the time of purchase, or purchase extra sets so you can vary the throughput and resolution. The slits are easily interchangeable. Table 1 shows the resolutions possible with the standard and optional slits. Table 1 Resolution of Mini Monochromators Instrument's Usable Wavelength Range Linear Dispersion (nm/mm) Resolution With These Slits (nm)* 50 ìm 100 ìm 150 ìm 300 ìm 600 ìm 1000 ìm 190 - 650 nm 5.54 0.28 0.55 0.83 1.66 3.32 5.54 200 - 800 nm 7.41 0.37 0.74 1.11 2.22 4.44 7.41 300 - 800 nm 7.21 0.36 0.72 1.08 2.16 4.32 7.21 500 nm - 1.2 ìm 11.29 0.56 1.13 1.69 3.39 6.77 11.29 * Instruments include 300 ìm x 4 mm slits; other slit sizes are available as options. Resolution = (slit width) X (linear dispersion) Optional Accessories We offer various accessories specifically for these Mini Monochromators (note: these accessories cannot be used with our fully featured instruments.) ENTRANCE SLIT GRATING EXIT SLIT FOLDING MIRRORS COLIMATING/ FOCUSING MIRROR

Open the catalog to page 1
Oriel Mini Monochromator - 2

S p e c t r o s c o p y I n s t r u m e n t s 1179 Email: sales@newport.com • Web: newport.com MONOCHROMATORS AND SPECTROGRAPHS SINGLE CHANNEL DETECTION SYSTEMS MINISPECTROMETERS BENCHTOP SPECTROMETERS AND CCD CAMERAS FT-IR SPECTROMETERS ACCESSORIES FOR SPECTROSCOPY INSTRUMENTS Order Sorting Filters Block the unwanted higher orders with an order sorting filter. Because of the unique input slit assembly of these monochromators, you cannot use our traditional flanged filter assemblies with these instruments. The assemblies for these monochromators have an integral slit; simply replace the...

Open the catalog to page 2
Oriel Mini Monochromator - 3

1180 MONOCHROMATORS AND SPECTROGRAPHS BENCHTOP SPECTROMETERS MINISPECTROMETERS SINGLE CHANNEL DETECTION SYSTEMS AND CCD CAMERAS FT-IR SPECTROMETERS Phone: 1-800-222-6440 • Fax: 1-949-253-1680 S p e c t r o s c o p y I n s t r u m e n t s ACCESSORIES FOR SPECTROSCOPY INSTRUMENTS Fig. 4 Dimensional diagram of Mini Monochromators Ordering Information Mini Monochromators These monochromators include two 300 ìm x 4 mm slits. To replace these slits with a set listed in the second table, contact a Sales Engineer at the time of purchase. Type Usable Wavelength Range Model Manual Mini Monochromator...

Open the catalog to page 3

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1 Pages

  2. M-401

    1 Pages

  3. newport ressource

    1640 Pages

  4. Motion PL30

    24 Pages

  5. Beamsplitters

    34 Pages

  6. Base Clamps

    1 Pages

  7. Rod Clamps

    1 Pages

  8. V-Blocks

    1 Pages

  9. Blackbodies

    2 Pages

  10. Beam Dump

    1 Pages