video corpo

LabLegs™ Upgrade Kits

LabLegs™ Upgrade Kits

Product catalog summary
Technical Reference Overview
This document provides detailed information on the upgrade options available for LabLegs™ products from Newport, focusing on optical tables and vibration control systems. It covers various components such as honeycomb, granite, and rigid structures, as well as breadboards, grid platforms, isolators, workstations, and isolated platforms.
LabLegs™ Upgrade Kits
LabLegs™ products can be upgraded to meet future needs. Non-isolating legs can be upgraded to isolated legs, and isolated legs without leveling can be upgraded to I-2000s. Height, tie-bar, and caster leg upgrades are also available.
Pneumatic Leveling Upgrades
All LabLegs™ Series can be upgraded to the I-2000 Stabilizer isolation leg. For the RL or SL Series, the I-2000 top chamber can be used for upgrades. Specific kits include:
  • PL-2000 to I-2000 Stabilizer: Use UPPL-2000 Leveling Valve Upgrade Kit
  • SL Series/RL Series to I-2000 Stabilizer: Use I-2000-100 (single leg) or I-2000-400 (four legs) Isolated Chamber Kit
Height Retrofits and Upgrades
LLS (LabLeg™ Spacer) Series upgrade kits allow for isolator height changes while the table remains in place. The tie-bar/caster (-TC version) allows further field upgrades.
Ordering Information
Details on specific upgrade kits:
  • I-2000 Isolator Upgrades: I-2000-100 and I-2000-400 for SL/RL to I-2000 upgrades
  • Height or Tie-bar/caster Upgrades: Various LLS spacers available in different heights, with tie-bar caster systems available as an option
Installation Notes
Ensure that any installation requiring separation from the LabLeg™ spacer and the top assembly does not tilt past 30 degrees to prevent oil leakage. All optical benches must be secure on a rigid jack system and fully blocked before attempting any leg removal for retrofit upgrades.
Benefits
The upgrade options offer lower initial and reconfiguration costs, ease of installation redesign, and flexibility in isolation type and isolator height.
See more

Catalog excerpts

LabLegs™ Upgrade Kits  -1

Phone: 1-800-222-6440 • Fax: 1-949-253-1680 1044 O p t i c a l Ta b l e s a n d V i b r a t i o n C o n t r o l HONEYCOMB, GRANITE OPTICAL TABLES TECHNICAL REFERENCE AND RIGID STRUCTURES BREADBOARDS AND GRID PLATFORMS WORKSTATIONS AND ISOLATORS ISOLATED PLATFORMS STRUCTURAL RAILS AND CARRIERS TESTING, ANALYSIS AND DESIGN LabLegs™ Upgrade Kits LabLegs™ products from Newport can be upgraded to meet expanding future needs. Non-isolating legs can be upgraded to isolated legs; isolated legs without leveling can be upgraded to I-2000s, and height; tie-bar and caster legs upgrades are also available. Pneumatic Leveling Upgrades All LabLegs™ Series can be upgraded to the I-2000 Stabilizer isolation leg— the most popular optical bench isolation leg ever built. For the RL or the SL Series, the I-2000 top chamber can be used to upgrade existing installations. PL-2000 to I-2000 Stabilizer: • Use UPPL-2000 Leveling Valve Upgrade Kit SL Series/RL Series to I-2000 Stabilizer: • Use I-2000-100 (single leg) or I-2000-400 (four legs) Isolated Chamber Kit Height Retrofits and Upgrades LLS (LabLeg™ Spacer) Series upgrade kits allow isolator height changes to be retrofit while the table remains in place. The tiebar/ caster (-TC version) allows further field upgrades. Ordering Information I-2000 Isolator Upgrades I-2000-100 I-2000 top assembly, 1 unit, upgrade from SL/RL to I-2000 I-2000-400 I-2000 top assembly, 4 unit, upgrade from SL/RL to I-2000 UPPL-2000 Upgrade from PL-2000 to I-2000 Height or Tie-bar/caster Upgrades LLS-13.5 Lab Leg Spacer, 13.5 in. LLS-16 Lab Leg Spacer, 16 in. LLS-19.5 Lab Leg Spacer, 19 in. LLS-22 Lab Leg Spacer, 22 in. LLS-23.5 Lab Leg Spacer, 23.5 in. LLS-28 Lab Leg Spacer, 28 in. * For Tie-Bar Caster Systems add -TC after each LabLeg™ Spacer part number (e.g. LLS-22-TC). The tie-bars with or without casters can then be purchased separately to properly match the table size. Note: Any installation requiring separation from the LabLeg™ spacer and the top assembly (RL, SL, PL/I-2000) requires that the leg be tilted to reach attachment bolts. Please ensure that PL-2000 and I-2000 do not tilt past 30 degrees or oil leakage may occur. CAUTION: Ensure that all optical benches are secure on a rigid jack system and fully blocked before attempting to remove any leg for retrofit upgrades. • Lower initial cost • Lower reconfiguration cost • Ease of installation redesign • Isolation type • Isolator height • Tie-bar casters

 Open the catalog to page 1

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1  Page

  2. M-401

    1  Page

  3. newport ressource

    1640  Pages

  4. Motion PL30

    24  Pages

  5. Nanopositioners

    40  Pages

  6. Beamsplitters

    34  Pages

  7. Optrical mirror

    33  Pages

  8. Motion System

    2  Pages

  9. Base Clamps

    1  Page

  10. Rod Clamps

    1  Page

  11. V-Blocks

    1  Page

  12. Blackbodies

    2  Pages

  13. Beam Dump

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.