Newport provides a wide range of high-speed fiber-optic detectors for photonics testing and measurement. These detectors come in amplified and unamplified models, featuring compact, durable cases with internally regulated power and current monitors.
Specifications
The detectors operate across a spectral range of 400 nm to 1700 nm, with models optimized for digital and analog communications. Key models include:
  • PX-D7: Fastest visible detector with 7 ps, 60 GHz.
  • D-8ir: Fastest 1310/1550 nm detector with 8 ps, 50 GHz.
  • DG-15xr: Fastest 750-1650 nm detector with 20 GHz.
  • AD-10ir: Fastest 1310/1550 nm amplified detector with 40 GHz.
  • AD-50APDir: Highest sensitivity amplified detector with -29 dBm.
Impulse and Frequency Responses
Impulse response plots are provided for various models, highlighting performance in amplitude and frequency. The DG-15ir and DG-15xr models are noted for their flat frequency response from DC-20 GHz, suitable for frequency-domain applications.
Amplified and Unamplified Models
Amplified models include integrated transimpedance amplifiers for high conversion gains, while unamplified models are battery-powered for ease of use. Both types offer different spectral responses and bandwidths to meet specific needs.
AC vs. DC Output Coupling
Detectors are available with DC output coupling for both DC and high-speed measurements. For AC-only measurements, an external DC-blocking capacitor is recommended.
VIS-ir Series Detectors
The VIS-ir series includes both unamplified and amplified detectors with broad spectral sensitivity and large multimode fiber-optic inputs, making them versatile for high-speed research applications.
Ordering Information
The document lists various models with specifications, including spectral response, impulse response, and output connectors, providing options for different measurement requirements.
Infrared Detectors and Receivers Overview
This section details infrared (IR) detectors and receivers, categorized by application, frequency response, and wavelength range.
1. IR Detectors
  • D-100IR Series: Operate within 950-1650 nm range with a response time of 100 ps, available with FC/PC or ST/PC connectors.
  • DG-15XR Series: Offer a flat frequency response of 20 GHz, available with FC/PC or ST/PC connectors.
  • D-25XR and D-70XR Series: Cover 700-1650 nm with response times of 25 ps and 70 ps, respectively.
2. Amplified Receivers
  • AD-200 and AD-300 Series: Cover 400-1700 nm with bandwidths of 2.5 GHz and 1.5 GHz, respectively.
  • AD-10IR and AD-40IR Series: Operate within 950-1650 nm range, offering bandwidths of 43 GHz and 12 GHz, respectively.
  • AD-50IR Series: Provide a 10 GHz bandwidth, available with AC or DC coupling options.
  • AD-40XR and AD-50XR Series: Cover 700-1650 nm with bandwidths of 12 GHz and 10 GHz, respectively.
  • AD-70XR and AD-180XR Series: Offer a 6 GHz bandwidth for extended IR applications.
  • AD-200XR Series: Provide a 2.5 GHz bandwidth for extended IR applications.
3. Reference Receivers
  • Models such as AD-50IR/RR, AD-200IR/RR, and AD-200XR/RR are designated as reference receivers for calibration or benchmarking, available with FC/PC and ST/PC connectors.
Conclusion
The document outlines various IR detectors and receivers tailored for specific applications and performance requirements, offering flexibility in connector type and coupling options for system integration.
See more

Catalog excerpts

High-Speed Photodetectors, GHz  -1

DETECTORS POWER AND ENERGY METERS BEAM ANALYSIS L i g h t Te s t a n d M e a s u r e m e n t I n s t r u m e n t s Email: [email protected] • Web: newport.com 1111 High-Speed Detectors Newport offers a complete line of Fiber-Optic High-Speed Detectors with thirteen new models to meet most measurement needs. These high-speed detectors find a wide variety of uses in the test and measurement of fast optical signals. Both amplified and unamplified models are available in compact, rugged, instrumentstyle cases. Each unit houses a sealed, fiber-coupled detector module together with internally regulated power, current monitor, power indicating LED’s and a convenient, top-mounted power switch. Unamplified models offer internal battery power for the utmost ease of use, and all models come with the choice of either ST or FC fiber optic input connectors (to be specified at time of order). These detectors are specifically designed to fulfill the variety of photonics testing and measurement applications including digital telephone and data communications, analog microwave communications, as well as general high-speed research from 300 ps temporal resolution (1.5 GHz) to 7 picoseconds (60 GHz). VIS-ir (400-1700 nm) products for broad measurement interests are available as well as a full range of IR (950-1650 nm) and XR (700-1650 nm) products optimized for communications applications. These products can also be used for free-space applications, by simply using the open end of a fiber-optic patch cord as the point of light collection. 50 ìm and 62.5 ìm core fibers offer collection numerical apertures of 0.2 and 0.3 in a very flexible, compact form that can easily be positioned inside any experimental setup. For more details about the detectors, please visit www.newport.com and search for 'High Speed Detectors'. • PX-D7: fastest visible detector available — 7 ps, 60 GHz • D-8ir: fastest 1310/1550 nm detector available — 8 ps, 50 GHz • DG-15xr: fastest 750-1650 nm detector available, 20 GHz • AD-10ir: fastest 1310/1550 nm amplified detector available, 40 GHz • AD-50APDir: highest sensitivity amplified detector available, -29 dBm The complete line of D and AD Series high-speed detectors were developed for Newport by Picometrix®, LLC, Ann Arbor, Michigan. Picometrix is dedicated to the development and manufacture of state-of-the art picosecond optoelectronic devices and instrumentation. Clean-pulse™ technology is a trademark of Picometrix. • Unamplified Models from 100 ps (4 GHz) to 8 ps (50 GHz) • 950–1650 nm, 700–1650 nm, and 400-1700nm versions • DG-15ir and DG-15xr for frequency domain applications to 20 GHz • Optimized for maximum responsivity • Self-contained, battery operated units • Amplified Models from 300 ps (1.5 GHz) to 10 ps (43 GHz) • 950–650 nm, 700–1650 nm and 400-1700nm versions • AD-40xr, fastest 700-1650 nm detector with 62.5 ìm fiber input • Integrated transimpedance amplifiers provide high conversion gains of up to 800 V/W • Built-in current monitor

 Open the catalog to page 1
High-Speed Photodetectors, GHz  -2

1112 Phone: 1-800-222-6440 • Fax: 1-949-253-1680 L i g h t Te s t a n d M e a s u r e m e n t I n s t r u m e n t s BEAM ANALYSIS POWER AND ENERGY METERS DETECTORS Detector Impulse Responses 1.0 0.5 0 0 20 40 60 Frequency (GHz) 0 -3 Amplitude Time (10 ps/div) -6 Voltage (dB) Time plot for the D-8ir 5 10 15 20 1.0 0.5 0 Frequency (GHz) 0 Amplitude Time (50 ps/div) 0 -3 -6 Voltage (dB) Time plot for the D-50ir 1.0 0.5 0 0 30 Frequency (GHz) 0 Amplitude Time (10 ps/div) 10 20 -3 -6 40 50 Voltage (dB) Time plot for the D-15 and D-15ir 1.0 0.5 0 0 3 6 9 12 Frequency (GHz) 0 -3 -6 Amplitude Time (100...

 Open the catalog to page 2
High-Speed Photodetectors, GHz  -5

DETECTORS POWER AND ENERGY METERS BEAM ANALYSIS L i g h t Te s t a n d M e a s u r e m e n t I n s t r u m e n t s Email: [email protected] • Web: newport.com 1115 AC vs. DC Output Coupling All of our high-speed detector and receiver products are available with DC output coupling which allows the user to make DC and high-speed optical measurements with the same detector or receiver model. If the user desires to make AC-only measurements, we recommend adding an external DC-blocking capacitor to the output of the device. By selecting the capacitor value, the user can choose a low-frequency cut-off...

 Open the catalog to page 5
High-Speed Photodetectors, GHz  -6

1116 Phone: 1-800-222-6440 • Fax: 1-949-253-1680 L i g h t Te s t a n d M e a s u r e m e n t I n s t r u m e n t s BEAM ANALYSIS POWER AND ENERGY METERS DETECTORS Unamplified Detectors - VIS-IR Detectors Model PX-D7 D-15 D-30 D-100 Spectral Response (nm) 400–900 400–1700 400–1700 400–1700 Impulse Response, Maximum (ps)(1) 7 15 30 100 Voltage Bandwidth, -3 dB Typical (GHz)(2) 60 29 15 4 Power Bandwidth, -3 dB Typical (GHz)(3) 45 21 11 2.8 Conversion Gain (into 50Ù) @ 850 nm (V/W) 1.7 10 10 10 Dark Current (nA) 100 50 50 50 NEP, Maximum (pW/ãHz)(4) 900 90 90 90 Maximum Average Power (mW) 5 5 5...

 Open the catalog to page 6
High-Speed Photodetectors, GHz  -7

DETECTORS POWER AND ENERGY METERS BEAM ANALYSIS L i g h t Te s t a n d M e a s u r e m e n t I n s t r u m e n t s Email: [email protected] • Web: newport.com 1117 Amplified AD-200-FC VIS-IR Receiver, 2.5 GHz, 400-1700 nm, FC/PC AD-200-ST VIS-IR Receiver, 2.5 GHz, 400-1700 nm, ST/PC AD-300-FC VIS-IR Receiver, 1.5 GHz, 400-1700 nm, FC/PC AD-300-ST VIS-IR Receiver, 1.5 GHz, 400-1700 nm, ST/PC AD-10IR-FC IR Receiver, 43 GHz, 950-1650 nm, FC/PC AD-10IR-ST IR Receiver, 43 GHz, 950-1650 nm, ST/PC Model Description AD-40IR-FC IR Receiver, 12 GHz, 950-1650 nm, FC/PC AD-40IR-ST IR Receiver, 12 GHz, 950-1650...

 Open the catalog to page 7

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1  Page

  2. M-401

    1  Page

  3. newport ressource

    1640  Pages

  4. Motion PL30

    24  Pages

  5. Nanopositioners

    40  Pages

  6. Beamsplitters

    34  Pages

  7. Optrical mirror

    33  Pages

  8. Motion System

    2  Pages

  9. Base Clamps

    1  Page

  10. Rod Clamps

    1  Page

  11. V-Blocks

    1  Page

  12. Blackbodies

    2  Pages

  13. Beam Dump

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.