cad

Electronic Shutter System
1Pages

{{requestButtons}}

Catalog excerpts

Electronic Shutter System - 1

48 L a s e r s Phone: 1-800-775-5273 • Fax: 1-650-964-3584 DIODE LASERS DIODE-PUMPED SOLID STATE LASERS LASER ACCESSORIES LASER ACCESSORY KITS GAS LASERS TUNABLE LASERS HIGH ENERGY PULSED LASERS ULTRAFAST LASERS Electronic Shutter System Our bistable electronic shutter employs a novel, patented design which requires no holding voltage or current to maintain the shutter in either the open or closed positions in normal operation. Since the shutter has only one moving part, the blade, it provides highly reliable performance and a service life of over 1 million operations. Pulses from 5–30 V drive the shutter—a positive pulse to open, and a negative pulse to close. Transition times are dependent on pulse amplitude and can be less than 3 msec. The 5.6 mm aperture accommodates laser beams with up to 5 W CW incident power. You can postmount the shutter by using the SP Series post, a VPH Series post holder, and a B-2 base, all included. Our digital shutter controller provides precise on/off control for durations from 10 msec–990 sec. A timed exposure can be initiated either from the front panel, through TTL compatible signals, or from the pushbutton cable. In the MANUAL mode, the shutter can be set opened to facilitate alignment or focusing. The RESET command, required before each actuation, prevents accidental opening and closes the shutter even during a timed opening. A 10 sec shutter opening delay can be activated as a convenience in holography, and other applications, when vibrations must die down before exposure. The 845HP shutter system includes the controller, a pushbutton cable, an 846HP shutter, and a base. Specifications Shutter Aperture 5.6 mm Height 46.9 mm Maximum Optical Power 5 W CW Cable 2.44 m (8 ft) terminated in a 4-pin DIN connector Electrical Input Positive or negative pulse with 5-30 V amplitude into 13 Ù Dimensions [in. (mm)] 2.25 x 1.35 x 1.14 (57.2 x 34.3 x 29) Controller Shutter Response Time <3 msec Exposure Duration 10 msec - 990 sec Timing Accuracy 0.05% ± 10 ìsec Maximum Repetition Rate 10 Hz Operating Modes TIME: Timed shutter opening Operating Modes MANUAL: Open and close shutter independent of time setting Operating Modes START: Initiates time or manual exposure Operating Modes RESET: Closes shutter Operating Modes DELAY: Optional 10 sec delay before shutter opening Pushbutton Cable [ft (m)] 8 (2.44) Power Requirements 115 VAC at 100 mA or 230 VAC at 50 mA Dimensions [in. (mm)] 3.25 x 6.00 x 6.25 (82.6 x 152.4 x 158.8) Ordering Information Model Description 845HP-01 115 V Shutter System 845HP-02 230 V Shutter System 846HP Shutter Only • Fast millisecond response time • Patented, reliable design • Handles up to 5 Watts CW • Crystal clock for precise timing • Wide range of shutter opening times • Shutter actuation can be pre-delayed • Manual or electronic triggering • Retrigger lockout prevents false command 34.8 13.7 57.2 29.0 8-32 THD (M4 W/ SUPPLIED 46.9 INSERT)

Open the catalog to page 1

All MICRO-CONTROLE / Spectra-Physics catalogs and technical brochures

  1. 10BPF10-310

    1 Pages

  2. M-401

    1 Pages

  3. newport ressource

    1640 Pages

  4. Motion PL30

    24 Pages

  5. Beamsplitters

    34 Pages

  6. Base Clamps

    1 Pages

  7. Rod Clamps

    1 Pages

  8. V-Blocks

    1 Pages

  9. Blackbodies

    2 Pages

  10. Beam Dump

    1 Pages