FD series

FD series
1 / 52 PagesView full catalog

FD series

Product catalog summary
Safety Precautions
Users must read the User's Manual thoroughly before using the air-conditioner. The device is designed for human cooling/heating and should not be used for other purposes like storing food or animals. Improper use can lead to safety hazards such as water or current leaks.
Installation Guidelines
Installation should be conducted by a specialist to avoid risks like water leakage, electric shocks, or fires. The outdoor unit must be securely fixed and not placed in areas with potential gas leaks or sparks.
Refrigerant and Environmental Considerations
The air-conditioner uses R410A refrigerant, which is non-toxic and non-flammable. Ventilation is necessary in small rooms to prevent refrigerant concentration from exceeding safe levels.
Usage in Snowy Areas
In snowy regions, a snow-prevention hood should be installed to prevent snow from blocking the air intake or freezing inside the unit. The unit should be elevated above expected snow levels.
Heating Performance
Heating performance is measured at an outdoor temperature of 7°C and indoor temperature of 20°C. Performance decreases with lower outdoor temperatures, necessitating additional heating.
Sound Levels
Sound values are measured in controlled environments and may be higher in actual installations due to surrounding noise.
Special Environmental Conditions
Avoid installing the unit in oily, acidic, or alkaline environments as these can degrade performance and cause corrosion.
Technical Specifications
The Hyper Inverter series offers quick temperature achievement and maintains nominal heating capacity at -15°C. The units are designed for high efficiency and long piping, supporting installation in cold areas with temperatures down to -20°C.
Advanced Technology
New technologies include DC twin rotary compressors and vector control for improved efficiency and reduced vibration. The design also allows for compact outdoor units with reduced size and weight.
Certifications
The manufacturing plants are ISO9001 and ISO14001 certified, ensuring quality and environmental management standards are met.
Specifications Overview
The document provides detailed specifications for various indoor and outdoor cooling/heating units, focusing on sound levels, airflow, dimensions, and power consumption.
Sound Levels
Indoor units have sound pressure levels ranging from 25 to 40 dB(A) depending on the mode and fan speed. Outdoor units range from 48 to 72 dB(A).
Airflow
Airflow for indoor units varies from 10 to 35 m3/min, while outdoor units maintain a consistent 100 m3/min.
Dimensions and Weight
Indoor units have dimensions ranging from 280 x 750 x 635 mm to 280 x 1,370 x 740 mm, with weights between 29 to 54 kg. Outdoor units range from 640 x 800 x 290 mm to 1,300 x 970 x 370 mm, weighing between 45 to 105 kg.
Power and Efficiency
Power consumption for cooling ranges from 1.02 to 4.28 kW, and for heating from 1.10 to 4.42 kW. EER/COP values indicate efficiency, with cooling ranging from 3.15 to 3.92 and heating from 3.58 to 4.09.
Operating Conditions
The units operate within a temperature range of -15 to 43°C for cooling and -20 to 20°C for heating. External static pressure can be adjusted up to 100 Pa.
Installation and Design
The units feature a compact and modern design, suitable for ceiling installation. They allow flexible piping layouts and are equipped with automatic external static pressure control to maintain optimal airflow.
Additional Features
Optional remote controls (wired and wireless) are available, and the units use R410A refrigerant. The document also highlights the importance of proper installation to avoid performance issues due to environmental factors like wind.
Specifications Overview
The document provides detailed specifications for various air conditioning units, including models FDF100VNVD1, FDF125VNVD, FDF140VNVD, and their corresponding outdoor units. The specifications cover cooling and heating capacities, power consumption, sound levels, and airflow rates under specific conditions (ISO-T1).
Key Specifications
  • Cooling conditions: Indoor temperature of 27˚CDB, 19˚CWB, and outdoor temperature of 35˚CDB.
  • Heating conditions: Indoor temperature of 20˚CDB, and outdoor temperature of 7˚CDB, 6˚CWB.
  • Power source options include 1 Phase 220-240V 50Hz and 3 Phase 380-415V 50Hz.
  • Nominal cooling capacity ranges from 10.0 kW to 14.0 kW, while heating capacity ranges from 11.2 kW to 16.0 kW.
  • Sound levels for indoor units range from 65 dB(A) to 73 dB(A) depending on the model.
Installation and Workability
The document highlights the ease of installation due to the use of flared and brazed connections, eliminating the need for brazing work inside the outdoor unit. The refrigerant precharged piping length extends up to 30m, facilitating smooth installation without additional refrigerant charging.
Performance and Efficiency
  • Energy Efficiency Ratios (EER) and Coefficients of Performance (COP) are provided for both cooling and heating modes, indicating the efficiency of the units.
  • Sound pressure levels and airflow rates are specified for different operational modes (High, Medium, Low).
Additional Features
  • Units are equipped with washable plastic net air filters.
  • Optional remote controls are available, both wired and wireless.
  • Enhanced corrosion resistance is achieved through the application of blue coated fins on the heat exchanger.
Limitations and Recommendations
  • Outdoor units should be installed in locations not influenced by natural wind to prevent operational issues at low temperatures.
  • Maximum piping length and height differences are specified to ensure optimal performance.
Specifications Overview
  • Cooling and Heating Capacities: The document provides detailed specifications for various models, including cooling and heating capacities ranging from 7.1 kW to 14.0 kW, with specific values for minimum and maximum capacities.
  • Power Consumption and Efficiency: Power consumption for cooling and heating is specified, along with Energy Efficiency Ratio (EER) and Coefficient of Performance (COP) values, indicating the efficiency of the units.
  • Sound Levels: Sound power and pressure levels are provided for both indoor and outdoor units, with values given in decibels (dB) for different operational modes.
  • Airflow Rates: Airflow rates are detailed for indoor units in cooling and heating modes, with values given in cubic meters per minute (m3/min).
  • Dimensions and Weight: The document lists the dimensions and net weight for both indoor and outdoor units, providing measurements in millimeters and kilograms.
  • Piping Specifications: Details on refrigerant piping sizes, lengths, and vertical height differences are included, along with specific instructions for branch piping arrangements.
  • Operating Temperature Range: The operating temperature range for cooling and heating is specified, with cooling ranging from -15°C to 46°C and heating from -15°C to 20°C.
  • Remote Control Options: Various wired and wireless remote control options are mentioned, including model numbers for compatibility.
Installation and Configuration
  • Multi-System Configurations: The document describes configurations for twin, triple, and double twin multi-systems, allowing for flexible installation in large or L-shaped rooms.
  • Branch Piping Instructions: Detailed instructions for branch piping, including the use of reducers and specific piping sizes, are provided to ensure proper installation and operation.
Additional Notes
  • Measurement Conditions: Specifications are measured under specific conditions (ISO-T1), with notes on potential variations due to ambient conditions.
  • Special Considerations: Recommendations for outdoor unit placement in low temperatures to prevent performance issues are included.
Specifications Overview
  • Nominal Cooling and Heating Capacities: Ranges from 7.1 kW to 28.0 kW for cooling and 8.0 kW to 31.5 kW for heating, depending on the model.
  • Power Consumption: Varies between 2.04 kW to 8.30 kW for cooling and 2.21 kW to 7.75 kW for heating.
  • EER/COP: Energy Efficiency Ratios (EER) and Coefficients of Performance (COP) range from 3.01 to 4.35.
  • Sound Levels: Indoor sound power levels range from 55 dB(A) to 68 dB(A), while outdoor levels range from 66 dB(A) to 74 dB(A).
  • Air Flow: Indoor air flow rates range from 11.5 m3/min to 30 m3/min, depending on the model and operation mode.
  • Dimensions and Weight: Indoor units have dimensions of 246 x 840 x 840 mm or 298 x 840 x 840 mm, with weights ranging from 18.5 kg to 32.5 kg. Outdoor units vary in size and weight.
  • Refrigerant Piping: Liquid/Gas piping sizes are 9.52 mm/15.88 mm or 12.7 mm/22.22 mm, with maximum lengths of 50 m to 100 m.
  • Operating Temperature Range: Cooling operates between -15°C to 43°C, and heating between -20°C to 20°C.
Procedures and Recommendations
  • Units should be installed in locations not influenced by natural wind when outdoor temperatures are -5°C or lower to prevent performance issues.
  • Remote control options include wired and wireless models for flexible operation.
Standards and Testing Conditions
  • Data measured under ISO-T1 conditions: Cooling at indoor 27°CDB/19°CWB and outdoor 35°CDB; Heating at indoor 20°CDB and outdoor 7°CDB/6°CWB.
Specifications
The document outlines specifications for indoor and outdoor units, including sound pressure levels, airflow rates, dimensions, and net weight. Indoor units have sound levels of 39/35/33 dB for cooling and heating, while outdoor units are at 51 dB. Airflow for indoor units is 16/14/12 m3/min, and outdoor units are 75/73 m3/min. Dimensions and weights vary across models, with indoor units weighing 49-52 kg and outdoor units 81-140 kg. Refrigerant piping sizes and maximum lengths are specified, with a vertical height difference allowance of up to 30 m.
Operating Conditions
Cooling operates between -15°C to 43°C, and heating between -20°C to 20°C. The document advises on installation considerations for low temperatures to prevent operational issues.
Environmental Considerations
All models use R410A refrigerant, complying with RoHS directives, and employ lead-free solder to enhance environmental protection. Energy efficiency is improved through high-efficiency DC motors and enhanced heat exchangers.
Energy Efficiency Ratings
The document discusses SEER and SCOP ratings as per EU regulations, indicating seasonal efficiency for heating and cooling. These ratings are part of the Eco-Design Directive for Energy Related Products.
Control Systems
The document details centralized control options for up to 128 indoor units using systems like SUPERLINK and BMS interfaces. Various network options and remote control configurations are available, including wired and wireless setups.
Remote Control Features
The eco touch remote control offers a touch screen interface with features like sleep timers, peak cut timers, and individual flap control. It supports multiple languages and provides energy-saving operations and user-friendly settings.
Specifications and Features
The document outlines the features of a remote control system for air conditioning units. It includes a USB connection (mini-B) and an LCD panel with light tap operation, noted as an industry first. The interface is simplified with only three buttons, enhancing usability. The LCD is a 3.8-inch full dot display with a backlight function and supports multi-language display in nine languages.
Operation Modes
The system supports various operation modes including Cooling, Dry, Auto, Fan, and Heating. It features a high-capacity operation mode for up to 15 minutes, which increases compressor speed and air flow volume. The high power operation adjusts the set temperature based on the mode and outdoor temperature.
Energy Efficiency
The system is designed for energy-saving operation, with a weekly timer function as a standard feature. This allows users to schedule operations up to four times a day. The RC-E5 model stores operation data and displays errors on the LCD, facilitating maintenance.
Control Systems
The RC-E5 remote control can manage up to 16 units individually and features an AUTO restart function. The RCH-E3 model is tailored for hotel use with limited control functions. Wireless control options are available with infrared receiver kits.
Technical Specifications
The document provides detailed specifications for various indoor and outdoor units, including energy class ratings, SEER, SCOP, Pdesignc, Pdesignh, and annual electricity consumption. The refrigerant used is R410A with a GWP of 1975. The units are compliant with European regulations for energy labeling and requirements for air-conditioners and comfort fans.
Temperature Control
The RC-E5 allows for adjustable temperature ranges to ensure energy-efficient air conditioning. The temperature sensor is positioned for improved sensitivity, allowing for precise control.
Certification Information
Mitsubishi Heavy Industries-Mahajak Air Conditioners Co., Ltd. holds ISO 14001 certification with certificate number 04104 1998 0813 E5. Additionally, Mitsubishi Heavy Industries-Haier (Qingdao) Air-conditioners Co., Ltd. is certified with ISO 9001 and ISO 14001, under certificate number 5170-1996-AQ-RCG-RvA.
Company Policy
The company follows a policy of continuous improvement and reserves the right to change specifications without prior notice.
Contact Information
Mitsubishi Heavy Industries, Ltd. is located at 16-5, Konan 2-chome, Minato-ku, Tokyo, 108-8215 Japan. More information can be found on their website: www.mhi.co.jp.
Environmental and Quality Standards
The document mentions participation in the ECC programme, indicating a commitment to environmental and quality standards. The ongoing validity of the certificates can be checked at www.eurovent-certification.com or www.certiflash.com.
See more

Catalog excerpts

FD series-1

Our Technologies, Your Tomorrow High Performan REMOTE CONTR Inverter Packaged Air-Conditioners

 Open the catalog to page 1
FD series-2

Our new advanced technology has realized high efficiency, strong heating and long piping. This contributes to the environmental protection through energy saving and permits installation of the units (3~6HP) considering a heating operation under temperature conditions down to 20˚C and design flexibility has been improved by extension of piping length to 100m. Hyper Inverter Strong heating (in case of 3~6HP) Long piping (in case of 4~6HP) -20˚C : Heating operation down to -20˚C -15˚C : Nominal heating capacity maintained at -15˚C -20˚C (Outdoor higher than Indoor) Height difference Piping length...

 Open the catalog to page 2
FD series-3

Micro Inverter Line up Micro Inverter Fits into elevators Size reduction and high efficiency performance on the DC twin rotary compressors(Micro Inverter 4-6HP) Employment of the scroll inverter compressors(8/10HP) Employment of DC twin rotary compressor has enabled to utilize a highspeed range of up to 120 rps at the maximum to secure the required capacity. Optimum compressor control has been realized by employing the vector control* and the starting current has been improved significantly compared with former models. Moreover, vibration has been reduced. Outside diameter of shell ø185mm * Vector...

 Open the catalog to page 3
FD series-4

Ceiling Cassette -4way- Indoor units FDT.FDTC Individual flap control system According to room temperature conditions, four directions of air flow can be controlled individually by following Flap control system. As individual flap control is available even after installation, installation area became wider than before. Due to optimization of outlet design of air flow with our new advanced technology, sufficient air flow is secured and long reach of air flow is realized.(FDT) Previous Flap control system The flap can swing within the range of upper and lower flap position selected with wired remote...

 Open the catalog to page 4
FD series-5

Duct Connected -High Static Pressure- External Static Pressure(E.S.P) control You can set External Static Pressure (E.S.P.) by method of manual setting on remote control. Indoor unit will control fan-speed to keep rated air flow volume at each fan speed setting. You can set required E.S.P. by wired remote control that calculated with the set air flow rate and pressure loss of the duct connected. RC-E5 E.S.P. button External Static Pressure (E.S.P.) can be set by E.S.P. button. Longer Duct Ceiling Keep the same air flow volume *Range of 80~150 Pa is set at ex-factory default. Range of 10~200 Pa...

 Open the catalog to page 5
FD series-6

SINGLE [OUTDOOR UNIT : INDOOR UNIT = 1 : 1] Capacity CEILING CASSETTE Indoor unit Outdoor 1phase unit 3phase 1phase Set 3phase Indoor unit Outdoor unit 1phase Set 1phase High Static pressure DUCT CONNECTED Low/Middle Static pressure CEILING SUSPENDED FLOOR STANDING Indoor unit Outdoor 1phase unit 3phase 1phase Set 3phase Indoor unit Indoor unit

 Open the catalog to page 6
FD series-7

Range (Rated Cooling Capacity) Micro Inverter 5.0 12.5 42,700 10,750

 Open the catalog to page 7
FD series-8

[ INDOOR UNIT ] CEILING CASSETTE -4way- R410A Remote control (Option) Wired balance of indoor unit Checking from access ports with detachable covers at each corner, arrangement of installation balance of indoor unit can be available without removing a panel. Workability is improved and time of installation is reduced. 2 Easy checking of drain pan Easy checking of drain pan condition is available by removing corner lid only. Due to new design changing fan motor is available without removing a panel. Temporally setting of drain pan is also available. Drain can be discharged upwards by 700mm from...

 Open the catalog to page 8
FD series-9

SPECIFICATIONS Set model name Indoor unit Outdoor unit Power source Nominal cooling capacity (Min~Max) Nominal heating capacity (Min~Max) Power consumption Cooling/Heating EER/COP Cooling/Heating Inrush current 220/230/240 V Max. running current Sound power Indoor Cooling/Heating level*1 Outdoor Cooling/Heating Cooling (Hi/Me/Lo) Sound Indoor Heating (Hi/Me/Lo) pressure level*1 Outdoor Cooling/Heating Cooling (Hi/Me/Lo) Indoor Heating (Hi/Me/Lo) Air ˚ow Outdoor Cooling/Heating Indoor Exterior HeightxWidthxDepth dimensions Outdoor Indoor Net weight Outdoor Ref.piping size Liquid/Gas Refrigerant...

 Open the catalog to page 9
FD series-10

[ INDOOR UNIT ] CEILING CASSETTE -4way Compact (600 X 600mm)- R410A Fits into standard 600 x 600 ceiling Remote control (Option) Wireless 1 Taking OA (Outside Air) into inside (Sound Pressure level in the Lo mode) OA Spacer TC-OAS-E (option) Joint Duct TC-OAD-E (option) Utilizing OA spacer which comes as optional equipment, outside air can be taken inside. Using 1 joint duct: OA up to 1.3m3/min. Using 2 joint ducts: OA from 1.3 to 2.6m3/min. Indoor Unit FDTC Current (Cooling/Heating) • 600mm Drain Pump New shape & angled louver redirects the air current away from the ceiling, to reduce ceiling...

 Open the catalog to page 10
FD series-11

530 (Suspension bolts pitch) Decorative panel The data are measured under the following conditions(ISO-TI). Cooling:lndoor temp, of 27"CDB, 19"CWB, and outdoor temp, of 35"CDB. Heating:lndoor temp, of 20"CDB, and outdoor temp, of 7"CDB, 6"CWB. *1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 : If a cooling operation is conducted when the outdoor air temperature is -5"C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and...

 Open the catalog to page 11
FD series-12

DUCT CONNECTED -High Static pressure- Remote control (Option) Wired Wireless Enhanced installation workability Quiet, Lightweight and Compact With the FDU71, the noise level is only 25dB (low), weight is only 34kg In addition 600mm Drain Pump is The indoor unit is completely hidden in the ceiling, so this is suitable for spaces with classy interior decoration. Models FDU200,250VF (Micro inverter only, refer to P23)

 Open the catalog to page 12
FD series-13

SPECIFICATIONS Set model name Indoor unit Outdoor unit Power source Nominal cooling capacity (Min~Max) Nominal heating capacity (Min~Max) Power consumption Cooling/Heating EER/COP Cooling/Heating Inrush current 220/230/240 V Max. running current Sound power Indoor Cooling/Heating level*1 Outdoor Cooling/Heating Cooling (Hi/Me/Lo) Sound Indoor Heating (Hi/Me/Lo) pressure level*1 Outdoor Cooling/Heating Cooling (Hi/Me/Lo) Indoor Heating (Hi/Me/Lo) Air ˚ow Outdoor Cooling/Heating External static pressure*2 Indoor Exterior HeightxWidthxDepth dimensions Outdoor Indoor Net weight Outdoor Ref.piping...

 Open the catalog to page 13