1. Catalogs
  2. MHIAE
  3. Eco.lution Commercial use Heat pump water heater

Eco.lution Commercial use Heat pump water heater

Eco.lution Commercial use Heat pump water heater
1 / 20 PagesView full catalog

Eco.lution Commercial use Heat pump water heater

Product catalog summary
Overview: The document provides comprehensive details on Mitsubishi Heavy Industries' ESA30E heat pump series, highlighting its ISO9001 and ISO14001 certifications for quality and environmental management.
Specifications: The ESA30E series offers capacities from 30kW to 480kW for commercial use and 627kW to 3135kW for industrial use, utilizing CO2 as a refrigerant for ecological benefits. It maintains high performance with a COP of 4.3, even in extreme temperatures.
Technology and Innovation: The Q-ton system features a unique CO2 two-stage compressor, enhancing efficiency and allowing hot water supply at temperatures as low as -25°C.
Environmental Impact: Using CO2 as a refrigerant, the system has a low Global Warming Potential (GWP) of 1 and zero Ozone Depletion Potential (ODP), reducing power consumption and CO2 emissions compared to traditional systems.
Applications: Suitable for residential, commercial, and industrial settings, the system is effective in cold climates, maintaining efficiency and capacity.
Awards and Recognition: The Q-ton system has received multiple awards for technology and energy efficiency from JSRAE and ECCJ.
User Interface: Features an advanced touch screen panel with a full dot Liquid Crystal display for user-friendly operation and management.
Introduction: Discusses the Q-ton EcoCute system's benefits, including energy efficiency and reduced operational costs, providing a steady hot water supply even in cold temperatures.
System Specifications: Ensures a consistent hot water supply at 80°C, compatible with both sealed and open tanks, enhancing energy efficiency.
Installation and Performance: Highlights the system's high efficiency, reliable performance in cold weather, and energy-saving capabilities.
Energy and Cost Efficiency: Adoption of Q-ton leads to a 66% reduction in annual running costs, offering higher heat output per unit price and lower carbon emissions.
Technical Specifications: Operates on a 3-phase power supply with a heating capacity of 30 kW, using R744 (CO2) refrigerant.
Installation Guidelines: Details on securing the unit, ensuring maintenance space, and applying anti-freezing measures.
Conclusion: The Q-ton EcoCute system offers significant energy savings and environmental benefits for various facilities.
Specifications: Details on an unvented hot water storage cylinder for commercial use, with specific material and pressure requirements.
Installation Procedures: Specifies pipe connection ports and temperature sensor requirements for accurate hot water detection.
Water Quality Criteria: Outlines criteria for water quality to prevent scale adhesion and corrosion.
Recommendations: Advises using 9 temperature sensors for precise control and consulting with a distributor for existing cylinder connections.
Additional Components: Includes components like a heat pump unit, remote controller, and various valves, with insulation requirements.
Water Piping Work: Key considerations include union joints, thermometers, and corrosion prevention measures.
Heat Pump Unit Installation Space: Ensures adequate service space for components and proper operation.
Electrical Wiring Work: Requires qualified professionals, compliance with standards, and proper grounding.
Specifications: Details on power supply and components, including remote controller and circuit breakers.
Procedures: Provides detailed procedures for connecting power cables and emphasizes proper grounding.
Standards and Recommendations: Wiring procedures follow JEAC8001, with guidelines for circuit breakers and wire specifications.
Key Data from Tables: Includes cable sizes, wire lengths, and tightening torque values.
Certifications: Mentions ISO9001 and ISO14001 certifications for quality and environmental management.
Additional Information: Notes on heat energy recovery and the company's continuous improvement policy.
See more

Catalog excerpts

Eco.lution Commercial use Heat pump water heater-1

Our Technologies, Your Tomorrow Commercial use Heat pump water heater Ecological energy Recovering heat energy from the air

 Open the catalog to page 1
Eco.lution Commercial use Heat pump water heater-2

Free energy from the air Overwhelming high performance and high efficiency "Our technology, Your tomorrow" is born Next-generation system developed with our combines responsibility to global environment The world's first CO2 two-stage compressor with the combination of rotary and scroll compression cycles The most ecological way for supplying hot water Natural refrigerant CO 2 Air to Water System Our Heat Pump series temperature output Water to Water System Heat recovery type Please refer to the other catalogue.

 Open the catalog to page 2
Eco.lution Commercial use Heat pump water heater-3

Q-ton (ESA 30-25 for the Japanese domestic market) received The 2011 Fiscal Year grand prize for Excellence in Energy Efficiency and Conservation in Products Category & Business Model Category from The Energy Conservation Center, Japan (ECCJ) as attached. Activities of ECCJ 1) Promotion of energy efficiency and conservation for the industry and commercial sectors 2) Providing information for further dissemination of energy-saving equipment 3) Providing information to encourage energy-saving lifestyle 4) Publishing and education 5) International cooperation 6) National examination for the qualified...

 Open the catalog to page 3
Eco.lution Commercial use Heat pump water heater-4

Heat Pump technology system What is a Heat Pump ? What is hot water supply by Heat Pump technology system ? Heat energy is absorbed from the outside air when it passes through the outdoor unit; the energy is transported to the indoor unit in the refrigerant [in this case CO2] within the piping system. This eliminates the need to bore holes or bury coils of pipes in the ground as used in conventional ground source systems. low temperature Increasing refrigerant temperature through compressing process by compressor Hot water heat transfer high temperature Decreasing refrigerant temperature through...

 Open the catalog to page 4
Eco.lution Commercial use Heat pump water heater-5

~Recommendable usage or customer~ for kitchen senior care home/hospital wedding venue resort hotel Supply center of meals school/company lunch center Spa/company dormitory/ recreation facility Transferring the heat to water and supplying city hotel/business hotel Conventional air to water heat pumps have performance issues to solve In the operation under low outdoor temperature, heating capacity and heating efficiency decrease significantly. conventional models Our development concept Keeping high capacity and high efficiency in cold conditions Q-ton is born Overwhelming high performance and...

 Open the catalog to page 5
Eco.lution Commercial use Heat pump water heater-6

Q-ton's unique advantages Advantage Overwhelming high capacity and high efficiency under extreme low hot water supply outdoor temperature Annual running cost Can keep the same capacity down to -7°C of the outdoor temperature Enough capacity even under low temperature High efficiency heat pump water heaters can save running cost compared with traditional oil or gas boilers. COP COP = Capacity (kW) / Power consumption (kW) Advanced energy saving operation and low running cost reduced amount Giving consideration to global environment by use of CO2 refrigerant High efficiency can minimize CO2 emission....

 Open the catalog to page 6
Eco.lution Commercial use Heat pump water heater-7

Easy operation Advanced touch screen panel with full dot Liquid Crystal display eco touch REMOTE CONTROL It makes a Pause by switciiuQ aum Setting of weekly operation pattern checking o-f operation pattern User friendly High level of visibility •LCD panel with light tap operation -Big LCD with 3.8 inch full dot display introduced as the industry's first 'Back light function •Simple interface with only three buttons water storage amount at a glance. save 11 Set 11 HBKT 11 Return Setting of schedule such as weekly operation pattern , day off (for a Maximum one year) and peak-cut timer can be set...

 Open the catalog to page 7
Eco.lution Commercial use Heat pump water heater-8

Hot water supply system Ecology and comfortable hot water supply system Starting an operation by a simple tap on button eco touch REMOTE CONTROL Unvented cylinder Unvented hot water storage cylinder Mixing valve Heat pump unit heat exchanger for air Recovering heat energy from the air heat exchanger for heating water expansion valve Unvented cylinder Unvented cylinder Unvented cylinder circulation pump The world's first two-stage compressor Scroll + Rotary compressor Water supply storage High efficiency operation Water supply System configuration guide Hot water amount Unvented cylinder Supply...

 Open the catalog to page 8
Eco.lution Commercial use Heat pump water heater-9

TOTAL ENERGY SOLUTION Listening to user's requirements in detail Make the plan for hot water supply Checking installation place and conditions correctly Present the best solution High efficiency heat pump equipment 1. Select the best system configuration 2. Saving energy 3. Reducing CO2 emission Present various service menu for regular maintenance 4. Present the plan to the user Planning to meet user's requirement with reliable design and construction for hot water supply Present the best total optimization plan to the user Guidance for selecting necessary quantity of Q-ton Connection up to 16...

 Open the catalog to page 9
Eco.lution Commercial use Heat pump water heater-10

Installation samples in Japan Osaka Prefecture Osaka City Adult Day Care Centers Seiseikai Medical Corporation Yakata Tower for the Elderly Yakata has comfortable bathing facilities for day-service users. As a precaution, a back-up system is equipped to provide hot water at all times. Annual running costs have been reduced by 66%. Compared to combustion-base water heaters (boilers), this system can reduce running costs by approximately 66% per year. Osaka Prefecture Suita City Two advantages of introducing this product. Q-ton works with both a sealed tank and an open tank. You can select the...

 Open the catalog to page 10
Eco.lution Commercial use Heat pump water heater-11

Lake Toya Hot Spring •Hokkai Hotel •Hotel Grand Toya •Toya Kanko Hotel •Toya Sansui Hotel Widely known hot spring resort where the G8 Hokkaido Toyako Summit 2008 was held. Hot water at 90 degrees C is available even when the temperature is – 25 degrees C. By utilizing a feed water heating method, hot water is supplied efficiently, subsequently saving energy. There are a number of ways to conserve the environment including introducing new energy resources and promoting carbon offsets. Introducing a heat pump is of these means. As it was recognized as a “Village working to reduce carbon emissions”...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.