PH2003
1 /2Pages

PH2003

PH2003
1 /2Pages

Catalog excerpts

PH2003-1

PRIMARY SWITCHED • SINGLE OUTPUT 2000 watts output power 3x 340-550V wide range input Mains input protected by fuse Output adjustable Parallel connection with load sharing Various monitoring and control signals Primary / secondary overvoltage protection Overtemperature protection Can be operated in any assembly position ORDER DATA ORDER NUMBERS Vo lo Preset range Vo Typ-No. Please ensure a distance of approx. 50 mm between both the air-inlet openings at the front of the housing and surrounding components or surfaces. Also make sure that outgoing air is not sucked back into the device during installation. Bayerwaldstr. 27 • 81737 Munich • Germany I fax: +49 89 678090-80

 Open the catalog to page 1
PH2003-2

AC / DC POWER SUPPLY PRIMARY SWITCHED ∙ SINGLE OUTPUT PH2003 SERIES 1. INPUT Input voltage range Efficiency Input current limitation Fuse 6. EMC AC 3 x 340-550V, 50/60Hz (340-460 V at Ua=96 V), 50/60 Hz or DC 480-800 V (480-650 V at Ua=96 V) Ext. DC-Fuse necessary (KLKD 15) 91-94.5% < 70 Apeak typ. - in cold state < 150 Apeak typ. - in hot state intern 3 x 12.5AT, external fuse with 16A to 63A necessary (C , D , K ) Interference suppression/ interference immunity Burst (input) (output) (relay) Surge (input) (output) (relay) 2. Output Preset range VOut Max. output Overload characteristic at 24V...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.