DG4120

DG4120

DG4120

Product catalog summary
Overview: This document provides technical specifications and operational details for the DG 4120, DG 4150, and DG 4150R series DC/DC power supplies designed for CompactPCI systems with galvanic insulation and quadruple output capabilities.
Specifications:
  • Input Voltage: DG 4120: 8.5 - 36 VDC; DG 4150 and DG 4150R: 36 - 76 VDC.
  • Output: Quadruple output with SELV compliance according to EN 60950. Outputs are short-circuit proof.
  • Protection: Includes primary/secondary overvoltage and overtemperature protection.
  • Control Inputs: ENABLE and INHIBIT for power control.
  • Signal Outputs: DERATE signal for operational status.
  • Standards Compliance: EMC standards EN 50081-1 and EN 50082-2.
Mechanical and Safety Features:
  • Dimensions: 19'' plug-in module according to DIN 41494 Part 5.
  • Connection: Connector M24/8 / DIN 41612.
  • Safety: Complies with EN 60950 / VDE 0805, Safety Class I, VDE 0100.
  • Temperature Range: 0 to +70°C with derating of 2%/K at +50°C.
Performance and Regulation:
  • Efficiency: 78 - 82% depending on the model.
  • Output Regulation: Line regulation < 0.2% for Vo1, Vo2; Load regulation < 0.1% for Vo1.
  • Protection: Overvoltage protection at 125% ±5% for Vo1, Vo2 and 125% ±10% for Vo3, Vo4.
  • Current Limitation: Typical 110% Inominal for Vo1, Vo2 and 140% Inominal for Vo3, Vo4.
Additional Features:
  • Hot-Plug Capability: Available for DG 4150R for redundancy operation.
  • Assembly Options: Kits available for DIN-rail or wall mounting.
  • Guarantee: 3-year warranty provided by MGV Stromversorgungen GmbH.
EMC and Interference:
  • Interference Suppression: Complies with EN 50082-2: 1997 and EN 61000 series standards.
  • Interference Emission: Complies with EN 50081-1: 1992 and EN 55011 / EN 55022 Class B.
See more

Catalog excerpts

DG4120-1

DC / DC POWER SUPPLY for CompactPCI WITH GALVANIC INSULATION QUADRUPLE OUTPUT DG 4120, DG 4150, DG 4150R SERIES – 19" plug-in module – Input: DG 4120: 8.5 - 36 VDC, DG 4150 and DG 4150R: 36 - 76 VDC – DG 4150R: For redundancy operation, Hot-plug – EMC Standards EN 50081-1 and EN 50082-2 – All outputs permanent short-circuit proof – Output SELV according to EN 60950 – Primary/secondary overvoltage protection – Overtemperature protection – Control inputs: ENABLE, INHIBIT – Signal outputs: DERATE – Assembly kit for DIN-rail or wall mounting 3 Years Guarantee! Front panel: 12TE - 60.6 Handle width: 3TE ORDER DATA Vo1 V +5.1 Io1 A 0 - 14 Vo2 V +3.3 Io2 A 0 - 14 Vo3 V +12 Io3 A 0-2 Vo4 V -12 Io4 A 0-1 Width TE 12 Height HE 3 +5.1 0 - 14 +3.3 0 - 14 +12 0-2 -12 0-1 12 3 +5.1 0 - 14 +3.3 0 - 14 +12 0-2 -12 0-1 12 3 Order numbers in italics Type No. DG4120-1/2G 15.9440.200 DG4150-3G 15.9440.300 DG4150R-3G 15.9440.400 Total output: You can take 120W max. from the device (at DG4150: 150W max. with forced ventilation) Additionally: Front panel (nature anodized) Assembly kit for DIN-rail Assembly kit for wall mounting 33.1594.000.011 15.7140.000.190 15.7140.000.290 MGV Stromversorgungen GmbH · Bayerwaldstraße 27 · 81737 München · Germany Tel. +49 / 89 / 67 80 90-0 · Fax +49 / 89 / 67 80 90 80 · Email: [email protected] · Internet: www.mgv.de

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.