Overview: The P140R Series is a primary switched, single output AC/DC power supply by MGV Stromversorgungen GmbH, offering 150 watts of output power. It features a 19" plug-in module with a 3U/8HP form factor, supports a wide input range, and includes active power factor correction for efficiency.
Specifications:
  • Input: AC input range of 100-264Vac or 85-264Vac with fan cooling, efficiency of 80-85%, and input current limitation of <30 Apeak in cold state and <40 Apeak in hot state.
  • Output: Adjustable voltage range with a maximum output power of 150W with fan cooling, operation indicators, ripple and noise voltage specifications, and a temperature coefficient of ≤0.055%/K.
  • Regulation: Line regulation of <0.1% and load regulation of <0.5% for Io 26-100% Inom.
  • Protection: Overvoltage protection, current limitation, short-circuit proof, and overtemperature protection.
  • EMC: Compliance with EN61000 standards for harmonics, immunity, and emissions.
  • Safety: Compliance with IEC 60950-1:2005 and other safety standards.
  • Operating Data: Temperature range of -25 to 70°C with derating from +50°C with fan cooling.
Features:
  • Hot-Swap capability and n+1 redundancy operation.
  • Modern microcontroller technology with digital interface options (LIN 1.3/opt. RS485).
  • Thermal load-share and optional load-share with interface.
  • Programmable signal outputs for power-fail, AC-fail, and temperature alerts.
Control and Indicators:
  • Two LEDs for status and error indication, with detailed signal explanations.
  • Output voltage can be adjusted via front panel buttons or bus interface.
  • Control inputs and status signals include shut-down control and status signal generation.
Bus Interface: The manual details standard specifications, applications, and protocol definitions for the bus interface, allowing for enhanced control and monitoring capabilities.
Parallel Operation: The P140R series supports parallel operation with features like redundancy, hot-swap, and thermal load sharing.
Error Management: Includes mechanisms for self-protection and failure pre-warning, such as over-voltage, under-voltage, and over-temperature protection.
Additional Information: The manual provides detailed explanations of pin connections, safety precautions, and operational guidelines to ensure proper use and integration of the power supply.
Output-Current Monitoring and Error Reset: The document outlines the procedure for resetting hardware errors in the P140R series power supply units. Errors can be reset by pressing two buttons simultaneously for at least one second or by sending a specific command sequence via the bus interface.
Bus Interface Specifications: The P140R series uses a LIN interface, requiring only one pin for communication. The interface allows addressing up to eight units and setting the unit as a master or slave.
Applications and Monitoring: The document describes how to configure and monitor units via the LIN bus interface, including switching the output voltage on or off, setting output voltage and current limits, and reading various data.
Protocol Definitions: The document details the protocol frames consistent with the LIN bus protocol, including conversion factors for calculating actual voltage and current from digital values.
Parallel Operation and Redundancy: The document explains "n+1" redundancy, where one power supply can fail without affecting the load, and the use of power transistors instead of redundancy diodes.
Hot-Swap and Thermal Load Sharing: The P140R series supports hot-swap, allowing units to be replaced during operation, and implements thermal load sharing to distribute current symmetrically among power supplies.
Glossary and References: The document includes a glossary of terms and references to additional resources, such as data sheets and safety information, available online.
Product Identification: The document describes a coding system for identifying power supply units using a 4-bit system.
Status Flags: The document lists several status flags indicating various conditions of the power supply.
Voltage and Current Measurement: The actual output voltage and current are represented by 12-bit ADC values, converted using specific conversion factors.
Temperature Measurement: Temperature is measured in a range from -40°C to +127°C using a two's complement system.
Setting Flags: These flags are stored in flash memory and can be modified via bus commands.
LIN Bus Slave Identifiers: The document provides read and write addresses for LIN bus slave identifiers.
Additional Information: The document concludes with a note on the availability of general terms and conditions, downloadable from the company's website.
See more

Catalog excerpts

AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-1

AC / DC POWER SUPPLY PRIMARY SWITCHED ∙ SINGLE OUTPUT P140R SERIES ■ 150 watts output power ■ 9“ plug-in module 3U / 8HP 1 ■ Wide range input 100-264VAC or 85-264VAC (with fan cooling) ■ Active power factor correction (PFC) ■ For n + 1 redundancy operation ■ Hot-Swap ■ Modern microcontroller technology ■ Digital interface (LIN 1.3 / opt.RS485) ■ Thermal Load-share or optional Load-share with interface ■ Operating data with interface readable ( Vo / Io / temperature / status ) ■ Common, programmable signal output for: Power-Fail (PF), AC-Fail (ACFAIL) and temp alert TE .. 174.43 2.5 100 128.4 CSA 22.2 No. 60950-1-03 UL Std. 60950 SI-2377 3U Front panel: 8HP - 40,3 Handle width: 3HP ORDER DATA Order numbers Vo V Io A Width HP Height U Type-No. 5.1 0 - 30 8 3 P140R-0530 15.9243.300 7.5 0 - 20 8 3 P140R-0720 15.9246.200 12 - 15 0 - 12.5 / 0 - 10 8 3 P140R-1212 15.9243.700 24 0 - 6.3 8 3 P140R-2406 15.9244.100 48 0 - 3.2 8 3 For Hot-Swap operation, there must be a breaktime (1 minute), because the input current inrush. P140R-4803 15.9244.500 Ventilation from bottom to top of the power supply and the housing-specific heatradiation must not be obstructed when installing the power supply. Ensure fire protection by means of the surrounding housing system. Additionally: Front panel (natural anodized) 33.1592.014.011 Assembly kit for DIN-rail 15.7140.000.190 Assembly kit for wall mounting 15.7140.000.290 LIN-Busmastercard LIN -> PMBus -> RS232 (3U/4HP) on enquiry MGV Stromversorgungen GmbH Bayerwaldstr. 27 • 81737 Munich • Germany fon: +49 89 678090-0 fax: +49 89 678090-80 www.mgv.de [email protected] 1

 Open the catalog to page 1
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-2

AC / DC POWER SUPPLY PRIMARY SWITCHED ∙ SINGLE OUTPUT P140R SERIES 1. input AC input range Efficiency Input current limitation Internal fuse 6. Safety 100-264Vac / 85-264Vac (fan cooling) 80-85% typ. < 30 Apeak typ. - in cold state < 40 Apeak typ. - in hot state 4AT 2. output Adjustment range Vo Max. output power Operation indicator Ripple Noise voltage Temperature coefficient switch performance Start-up delay Rise time 5V/7.5V/24V/48V-type: -5/+10% 12V-type: -5/+37% 150W with fan cooling > 1.5m/s green LED for Ua / AC good red LED for Ua / AC / Temp. fail < 0.6% Vnom (150 KHz band width) < 1.0%...

 Open the catalog to page 2
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-3

Extended Manual for the P140R Series ____________________________________________________________________________________ Extended Manual for the P140R Series Contents 1. PRODUCT DESCRIPTION 2 1.1 Functional description 2 1.2 Indicators and controls 2 1.3 Control inputs and status signals 3 1.4 Stand-by 4 1.5 Error management 5 2. BUS INTERFACE 5 2.1 Standard specifications 5 2.2 Applications 6 2.3 Protocol definitions 7 3. PARALLEL OPERATION 7 3.1 Redundancy 7 3.2 Hot-Swap 8 3.3 Thermal load sharing 8 GLOSSARY 11 REFERENCES 12 APPENDIX 1 13 MGV Stromversorgungen GmbH Bayerwaldstr. 27 • 81737...

 Open the catalog to page 3
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-4

Extended Manual for the P140R Series ____________________________________________________________________________________ 1. Product description 1.1 Functional description The outstanding advantage of the P140R series is its combination of MGV’s proven design of switching power supplies with the flexibility of micro-controllers. In fact, the P140R series uses two microcontrollers on each side of the galvanic separation for various control and monitoring tasks. For more details, please refer to the data sheet of the P140R series (see Reference [1]). 1.2 Indicators and controls To unambiguously...

 Open the catalog to page 4
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-6

Extended Manual for the P140R Series ____________________________________________________________________________________ Via the bus interface (see chapter 2), you can activate or de-activate any status signal. Please note that all status signals activated are combined by a logical OR. Important Notes • When there is no primary supply available (input voltage out of range or physically disconnected), there is no power supply for the status signal transistor mentioned above. • When you connect several units in parallel, the status signal following a signal event is indeterminate. Therefore, trigger...

 Open the catalog to page 6
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-7

Extended Manual for the P140R Series ____________________________________________________________________________________ 1.5 Error management All units of the P140R series provide the usual mechanisms for self-protection and failure pre-warning: - over-voltage protection for both the primary and secondary side (OVP) - under-voltage protection on the primary side (UVP) - over-temperature protection for both the primary and secondary side (OTP). After a pre-warning time of approx. 10 s (OTPA, see chapter 1.3), the over-temperature protection (OTP) switches the unit into stand-by (see chapter 1.4)....

 Open the catalog to page 7
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-8

Extended Manual for the P140R Series ____________________________________________________________________________________ Recommended resistors for LIN bus addressing (between Pin 20 (ADR/SD) and the output ground (-L): LIN bus address 0 (Master) Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Slave 7 Shut-down (OFF) Resistor value (1% tolerance) open (≥100 kΩ) 51 kΩ 27 kΩ 15 kΩ 10 kΩ 6.2 kΩ 3.9 kΩ 2.2 kΩ jumpered (≤1.2 kΩ) Via the LIN bus interface, you can read out all relevant information in digital form (like status, voltage, current or temperature). The firmware of every unit provides a...

 Open the catalog to page 8
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-9

Extended Manual for the P140R Series ____________________________________________________________________________________ 2.3 Protocol definitions The driver hardware and the protocol frames are consistent with the LIN bus protocol (see Reference [3]). The bus uses an internal supply voltage of 8 to 14 V. For further details, see the data format and command structure in the LIN bus application protocol P140R, Appendix 1. In order to calculate the actual voltage and/or current from the digital values returned from the units over the LIN bus, you need a conversion factor. The conversion factor...

 Open the catalog to page 9
AC / DC POWER SUPPLY PRIMARY SWITCHED ? SINGLE OUTPUT P140R SERIES-10

Extended Manual for the P140R Series ____________________________________________________________________________________ 3.2 Hot-Swap “Hot-swap” means that any unit of an „n+1“ redundancy system may be replaced during operation. As long as you keep to the remarks in the data sheet [1] and in the safety notes [2], all units of the P140R series (with an H15 connector) are ready for hot-swap. Allow the unit a minimum cooling time of one minute before you plug it in again. 3.3 Thermal load sharing Conventional load sharing is a good way of sharing the total current symmetrically between several...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.