Low power NDIR sensor for industrial safety MIPEX-02 is intended for automatic continuous measurement of methane, hydrocarbons or carbon dioxide concentration in atmosphere of hazardous areas. Technical specifications Parameter Measurement range, % vol. Accuracy (+20…+25⁰C) Response time (T90) sec,with dust filter Value 0…2.5,0…5, 0…100 – CH₄ 0…1.5,0…2.5 – C₃H₈ 0…1.5,0…5 – CO₂ ±0.1% vol. or ±5% of reading (whichever is greater) for CH₄ ±0.05% vol. or ±5% of reading (whichever is greater) for C₃H₈ or CO₂ ≤30 – CH₄ or C₃H₈ ≤60 – CO₂ Operating temperature Humidity tolerance Supply voltage Average current, μA Stainless steel or Polycarbonate Lexan® Features • Low power consumption – less than 2.5 mW. • Fully digital. • Smart sensor with embedded microcontroller returns linearized, temperaturecompensated output data (-40...+60 °C). 5.5 (Polycarbonate Lexan®) 16.6 (Stainless steel) • Response time (T90) without dust filter less than 15 seconds. • Industry standard size (⌀20.3×16.6 mm). • Provides intrinsically safe explosion protection level “ia”. I M1 / II 1G Ex ia op is I Ma / Ex ia op is IIC Ga according to EN IEC 60079-0 / EN 60079-11 / EN IEC 60079-28 C I, Div1, Gr A,B,C,D; C I, Zone 0, AEx ia op is IIC Ga; Ex ia op is IIC Ga according to UL 913, UL 60079-0, UL 60079-11, UL 60079-28, CSA C22.2 No.60079-0, CSA C22.2 No.60079-11 Ex ia op is I Ma/Ex ia op is IIC Ga according to IEC 60079-0, IEC 60079-11, IEC 60079-28
Open the catalog to page 1Ultra-low power NDIR sensor for portable and wireless detectors MIPEX-04 is an ultra-low power NDIR sensor for continuous methane and propane detection in portable and wireless safety systems, including gas clip devices and battery-powered analyzers. Technical specifications Value 0…5, 0…100– CH₄ Measurement range, % vol. 0…2.5 – C₃H₈ ±0.1% vol. or ±5% of reading (whichever is greater) for CH₄ Accuracy (+20…+25⁰C) ±0.05% vol. or ±5% of reading (whichever is greater) for C₃H₈ ≤30 – CH₄ Response time(T90) sec., with ≤45 – dust filter C₃H₈ Operating -40…+60 °C temperature, Humidity Up to 98% (without...
Open the catalog to page 2MIPEX-04 ppm is a high-performance NDIR sensor with 10 ppm resolution, designed to detect methane and propane at low concentrations. Technical specifications tolerance Upto98% (without condensation) Average current; pA Less than 100 Features • Target application: portable gas detectors for industrial safety with 10 ppm resolution. • Allows designing battery operated gas detector lasting more than 12 months without charge. • Power consumption: less 0.3 mW. • Smart sensor with embedded microcontroller returns linearized, temperature-compensated output data. • LED based dual wavelength technology....
Open the catalog to page 3Ultra-low power NDIR sensor in the 4th series housing for portable and wireless devices MIPEX-05 is an ultra-low power infrared gas sensor designed for automatic continuous measurement of methane, hydrocarbons and CO2 concentrations in hazardous areas. Technical specifications Parameter Measurement range, % vol. Accuracy (+20…+25⁰C) Response time(T90) sec., with dust filter Operating temperature Humidity tolerance Value 0 … 5 , 0…100 – CH₄ 0…2.5, 0…20 – C₃H₈ 0…5, 0…10 – CO₂ ±0.1% vol. or ±5% of reading (whichever is greater) for CH₄ ±0.05% vol. or ±5% of reading (whichever is greater) for C₃H₈...
Open the catalog to page 4Ultra-low power NDIR ppm range gas sensor in the 4th series housing MIPEX-05 ppm is a high-sensitivity version of an ultra-low power infrared gas sensor in the 4th series housing with 10 ppm resolution for hydrocarbons measurement in ppm and LEL concentrations. Technical specifications Parameter Measurement range Accuracy (+20…+25⁰C) ±30 ppm Response time(T90) sec., with dust filter Operating temperature Humidity tolerance 0.1…5.0% vol. – CH₄ 0.06 … 2.5% vol. – C₃H₈ ±5% of reading (whichever is greater) for CH₄ ±5% of reading (whichever is greater) for C₃H₈ Polycarbonate Lexan® • Average power...
Open the catalog to page 5Ultra-low power NDIR sensor with standard-pin configuration for portable and wireless devices MIPEX-06 is an ultra-low power infrared gas sensor designed for automatic continuous measurement of hydrocarbons and CO2 concentrations in hazardous areas. Technical specifications Parameter Measurement range, % vol. Accuracy (+20…+25⁰C) Response time(T90) sec., with dust filter 0…5, 0…10 – CO₂ ±0.1% vol. or ±5% of reading (whichever is greater) for CH₄ ±0,05% vol. or ±5% of reading (whichever is greater) for C₃H₈ or CO₂ ≤25 – CH₄ ≤30 – C₃H₈ ≤25 – CO₂ Features • Power consumption: less than 0.2 mW. •...
Open the catalog to page 6MIPEX-1H is a compact infrared sensor designed for measuring methane, propane, and carbon dioxide concentrations in small-sized and portable gas detectors. Response time (T90) sec., with dust filter Operating temperature ±0.1%vol.or ±5% of reading (whichever is greater) for CH4 ±0.05%vol.or ±5% of reading (whichever is greater) for C3H8 or CO2 Dimensions Housing material Weight, g. Sensor is designed in compliance with: • Power consumption: less than 0.2 mW. • Smart sensor with embedded microcontroller returns linearized, temperature-compensated output data. • LED based dual wavelength technology....
Open the catalog to page 7MIPEX-1F rcHrSTAn optical measurement module for stationary gas analysis systems with an extended operating temperature range MIPEX-1F - a ready-to-use optical measurement module for industrial safety, designed for automatic continuous monitoring of hydrocarbon concentrations in explosive atmospheres. Technical specifications Parameter Value ±0.1%vol.or ±5% of reading (whichever is greater) for CH4 ±0.05%vol.or ±5% of reading (whichever is greater) for C3H8 toierance Up to 98% (without condensation) 600 pA (max under normal conditions, UART) Average current Optional: 700 pA max under normal Housingmaterial...
Open the catalog to page 8