Low power NDIR sensor for industrial safety MIPEX-02 is intended for automatic continuous measurement of methane, hydrocarbons or carbon dioxide concentration in atmosphere of hazardous areas. Technical specifications Parameter Measurement range, % vol. Accuracy (+20…+25⁰C) Response time (T90) sec,with dust filter Operating temperature Humidity tolerance Value 0…2.5,0…5, 0…100 – CH₄ 0…1.5,0…2.5 – C₃H₈ 0…1.5,0…5 – CO₂ ±0.1% vol. or ±5% of reading (whichever is greater) for CH₄ ±0.05% vol. or ±5% of reading (whichever is greater) for C₃H₈ or CO₂ ≤30 – CH₄ or C₃H₈ ≤60 – CO₂ Supply voltage Average current, μA Stainless steel or Polycarbonate Lexan® • Low power consumption – less than 2.0 mW. • Fully digital. • Smart sensor with embedded microcontroller returns linearized, temperaturecompensated output data (-40...+60 °C). • Response time (T90) without dust filter less than 15 seconds. • Industry standard size (⌀20.3×16.6 mm). 5.5 (Polycarbonate Lexan®) 16.6 (Stainless steel) Marking and standards: I M1 / II 1G Ex ia I Ma / Ex ia IIC Ga according to EN IEC 60079-0 / EN 60079-11 C I, Div1, Gr A,B,C,D; C I, Zone 0, AEx ia IIC Ga; Ex ia IIC Ga according to UL 913, CAN/CSA-C22.2 No.157-92 Ex ia I Ma/Ex ia IIC Ga according to IEC 60079-0, IEC 60079-11 • Provides intrinsically safe explosion protection level “ia”. • D
Open the catalog to page 1Ultra-low power NDIR sensor for portable and wireless detectors MIPEX-04 is an ultra-low power NDIR sensor for continuous methane and propane detection in portable and wireless safety systems, including gas clip devices and battery-powered analyzers. solution, wireless and clip gas detectors for industrial safety. Housingmaterial Polycarbonate Lexan® • High-sensitivity version with 10 ppm resolution available for propane. • Allows designing clip gas detector lasting no less than 24 months without charge. • Lowest available power consumption among combustible gas sensors. Average operating current...
Open the catalog to page 2Ultra-low power infrared ppm range gas sensor MIPEX-04 ppm is a high-performance NDIR sensor with 10 ppm resolution, designed to detect methane and propane at low concentrations. Technical specifications Parameter Measurement range Accuracy (+20…+25⁰C) Response time(T90) sec, with dust filter ±5% of reading (whichever is greater) for CH₄ ±5% of reading (whichever is greater) for C₃H₈ Operating temperature Humidity tolerance Supply voltage Polycarbonate Lexan® Marking and standards: I M1 / II 1G Ex ia I Ma / Ex ia IIC Ga according to EN IEC 60079-0 / EN 60079-11 C I, Div1, Gr A,B,C,D; C I, Zone...
Open the catalog to page 3MIPEX-05Ultra-low power sensor in the 4th series housing for portable and wireless devices MIPEX-05 is an ultra-low power infrared gas sensor designed for automatic continuous measurement of methane, hydrocarbons and CO2 concentrations in hazardous areas. Technical specifications Parameter Value Housingmaterial Polycarbonate Lexan® Sensor is designed in compliance with: Features • Ultra-low power consumption. Average current at constant measurement of concentration is less than 60 ^A. • Smart sensor with embedded microcontroller returns linearized, temperature-compensated output data. • LED based...
Open the catalog to page 4Ultra-low power sensor with thick-pin configuration for portable and wireless devices MIPEX-06 is an ultra-low power infrared gas sensor designed for automatic continuous measurement of methane, hydrocarbons and CO2 concentrations in hazardous areas. Parameter Value • Ultra-low power consumption. Average current consumption at constant measurement of concentration is less than 60 ^A. • Industry standard size with thick-pin configuration. • Smart sensor with embedded Sensor is designed in compliance with: microcontroller returns linearized, temperature-compensated output data. • LED based dual...
Open the catalog to page 5MIPEX-1S is a compact infrared sensor designed for measuring methane, propane, and carbon dioxide concentrations in small-sized and portable gas detectors. Technical specifications tolerance Up to 98% (without condensation) • Ultra-low power consumption. Average current consumption at constant measurement of concentration is less than 65 ^A under normal conditions. • Smart sensor with embedded microcontroller returns linearized, temperature-compensated output data. • LED based dual wavelength technology. Lifetime: more than 10 years. Reduced response time (T90). Housingmaterial Polycarbonate...
Open the catalog to page 6An optical measurement module for stationary gas analysis systems with an extended operating temperature range MIPEX-1F – a ready-to-use optical measurement module for industrial safety, designed for automatic continuous monitoring of hydrocarbon concentrations in explosive atmospheres. Technical specifications Parameter 0...2.5 – C₃H₈ ±0.1% vol. or ±5% of reading (whichever is greater) for CH₄ ±0.05% vol. or ±5% of reading (whichever is greater) for C₃H₈ Response time(T90) sec. Operating temperature Humidity tolerance Supply voltage 600 µA (max under normalconditions, UART) Average current Optional:700...
Open the catalog to page 7