Overview: The M2CA is a super-mini signal conditioner from the Mini-M Series designed to convert alternating current from a current transformer into a standard process signal. It features average sensing with RMS calibration, minimal ripple, and includes a CT Protector for open-circuit protection.
Functions & Features: The device is used for centralized monitoring and control of motors, pumps, or heaters by DCS. It ensures that the rerouted input signal does not pass through the base socket to prevent melting from motor rush current.
Model and Ordering Information: The model number is M2CA-[1][2]-[3][4], where each bracket represents a specific configuration option for input, output, power input, and additional options. Input options include 0-1 A AC or 0-5 A AC. Output options range from various DC current and voltage outputs. Power input can be AC or DC with specific voltage ranges. Options include standards and approvals like CE, UKCA, and UL, as well as coating and terminal screw material choices.
General Specifications: The M2CA features a plug-in construction with M3 screw terminals and a flame-resistant resin housing. It provides isolation between input, output, and power. The device supports sine wave input with average sensing and has adjustable zero and span settings.
Input and Output Specifications: The input frequency is 50 or 60 Hz with a burden of ≤ 0.1 VA for 0-1 A and ≤ 0.5 VA for 0-5 A. The output specifications include DC current and voltage options with specific load resistances and spans.
Installation and Performance: The device can be mounted on a surface or DIN rail, operating within -5 to +55°C and 30 to 90% RH. It has a power consumption of approximately 3-5 VA for AC and 3 W for DC. Performance metrics include an accuracy of ±0.3%, a response time of ≤ 0.5 sec, and a ripple of 0.5% p-p max.
Standards & Approvals: The M2CA complies with EU and UK conformity standards, including EMC and Low Voltage Directives. It is approved for UL/C-UL nonincendive Class I, Division 2, and general safety requirements.
External Dimensions & Terminal Assignments: The document provides detailed dimensions and terminal assignments for installation, including a schematic circuitry and connection diagram.
See more

Catalog excerpts

M2CA-1

MODEL: M2CA Super-mini Signal Conditioners Mini-M Series CT TRANSMITTER (average sensing, RMS calibrated) Functions & Features • Converts alternating current from a current transformer into a standard process signal • Minimum ripple • Rerouted input signal does not pass through the base socket in order to protect it from melting caused by rush current of a motor • CT Protector provided for open-circuit protection Typical Applications • Centralized monitoring and control of motors, pumps or heaters by DCS • Monitoring power line and power supply current D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (Select ‘/N’ for ‘Standards & Approvals’ code.) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (90 – 264 V for UL) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (110 V ±10 % for UL) ORDERING INFORMATION [4] OPTIONS (multiple selections) • Code number: M2CA-[1][2]-[3][4] Specify a code from below for each of [1] through [4]. (e.g. M2CA-5A-M2/CE/Q) • Special output range (For codes Z & 0) • Specify the specification for option code /Q (e.g. /C01/S01) [1] INPUT (sine wave) Current 1: 0 – 1 A AC 5: 0 – 5 A AC [2] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) Standards & Approvals (must be specified) /N: Without CE, UKCA or UL /CE: CE marking /UK: CE, UKCA marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to our web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating (UL not available) /C04: Polyolefin coating (UL not available) TERMINAL SCREW MATERIAL /S01: Stainles

 Open the catalog to page 1
M2CA-2

MODEL: M2CA GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Input waveform Average sensing: Sine wave Overrange output: 0 to 120 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) INPUT SPECIFICATIONS Frequency: 50 or 60 Hz Input burden: ≤ 0.1 VA (input 0 – 1 A) ≤ 0.5 VA (input 0 – 5 A) Overload capacity: 500 % of rating for 5 sec., 120 % continuous Operational range: 0...

 Open the catalog to page 2
M2CA-3

MODEL: M2CA EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch] approx. 200 [7.9] (total of both sides) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM SOURCE K INPUT TRANSFORMER Average Operation Output Driver Base Socket Specifications are subject to change without notice.

 Open the catalog to page 3

All MG Co., Ltd. catalogs and technical brochures

  1. M2DNY

    3  Pages

  2. M2CDS

    4  Pages

  3. M2BW

    2  Pages

  4. M2BS-16

    5  Pages

  5. M2BS2

    5  Pages

  6. M2BS-16

    5  Pages

  7. M2BD

    7  Pages

  8. M2BC

    8  Pages

  9. M2AVS

    4  Pages

  10. M2AS

    5  Pages

  11. M2AP

    4  Pages

  12. M2AMS

    4  Pages

  13. M2ADS

    4  Pages

  14. M2AC

    3  Pages

  15. CNT

    2  Pages

  16. CLSE

    2  Pages

  17. CLSB

    3  Pages

  18. MCN-CON

    1  Page

  19. COP-US

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.