video corpo

M2ADS

M2ADS

M2ADS

Product catalog summary
Overview: The M2ADS is a super-mini signal conditioner from the Mini-M Series designed to receive two DC inputs and provide an output proportional to their sum. It is typically used for applications like adding two flow signals.
Specifications:
  • Inputs: Supports various DC current and voltage ranges with specific input resistances. Custom specifications can be defined for certain codes.
  • Outputs: Offers both current and voltage output options with defined load resistances. Custom specifications are available.
  • Power Input: Available in both AC (100-240 V) and DC (24 V, 11-27 V, 110 V) options.
  • Options: Includes standards and approvals like CE and UL, and additional options such as different coatings and terminal screw materials.
General Specifications:
  • Construction: Plug-in with M3 screw terminals.
  • Housing: Made of flame-resistant resin.
  • Isolation: Input to output to power isolation with specific potential requirements.
  • Adjustments: Zero and span adjustments available on the front.
  • Equation: Output is calculated as K1 × Input 1 + K2 × Input 2, with K1 and K2 specified during ordering.
Performance:
  • Accuracy: ±0.2% of span, with variations if K1 or K2 exceed 1.00.
  • Temperature Coefficient: ±0.015%/°C.
  • Response Time: ≤ 0.5 seconds for 0-90% range.
  • Insulation Resistance: ≥ 100 MΩ with 500 V DC.
  • Dielectric Strength: 2000 V AC for 1 minute.
Standards & Approvals:
  • EU Conformity: Complies with EMC and Low Voltage Directives.
  • RoHS Directive: Compliant.
  • UL/C-UL Approval: Nonincendive Class I, Division 2, and general safety requirements.
Installation:
  • Power Consumption: Varies with voltage, approximately 3-5 VA for AC and 3 W for DC.
  • Operating Conditions: Temperature range of -5 to +55°C and humidity of 30 to 90% RH.
  • Mounting: Can be surface or DIN rail mounted.
  • Weight: 150 g (0.33 lb).
Dimensions & Connections: Detailed dimensions and terminal assignments are provided, with no extra space needed between units when mounting.
See more

Catalog excerpts

M2ADS-1

MODEL: M2ADS Super-mini Signal Conditioners Mini-M Series ADDER Functions & Features • Receives two DC inputs and provides an output proportional to the addition of the inputs Typical Applications • Adding two flow signals 2: 0 – 100 mV DC (Input resistance 100 kΩ min.) 3: 0 – 1 V DC (Input resistance 1 MΩ min.) 4: 0 – 10 V DC (Input resistance 1 MΩ min.) 5: 0 – 5 V DC (Input resistance 1 MΩ min.) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) [2] INPUT 2 Same range availability as Input 1 • Code number: M2ADS-[1][2][3]-[4][5] Specify a code from below for each of [1] through [5]. (e.g. M2ADS-6AA-M2/CE/Q) • Ratios (e.g. K1 = 0.10, K2 = 2.00) • Special input and output ranges (For codes Z & 0) • Specify the specification for option code /Q (e.g. /C01/S01) Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) MODEL: M2ADS-[1][2][3]-[4][5] ORDERING INFORMATION Current A: 4 – 20 mA DC (Input resistance 250 Ω) A1: 4 – 20 mA DC (Input resistance 50 Ω) B: 2 – 10 mA DC (Input resistance 500 Ω) C: 1 – 5 mA DC (Input resistance 1000 Ω) D: 0 – 20 mA DC (Input resistance 50 Ω) E: 0 – 16 mA DC (Input resistance 62.5 Ω) F: 0 – 10 mA DC (Input resistance 100 Ω) G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) J: 0 – 10 μA DC (Input resistance 1000 Ω) K: 0 – 100 μA DC (Input resistance 1000 Ω) GW: -1 – +1 mA DC (Input resistance 1000 Ω) FW: -10 – +10 mA DC (Input resistance 100 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Input resistance 10 kΩ min.) AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (90 – 264 V for UL) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC (Operational

 Open the catalog to page 1
M2ADS-2

MODEL: M2ADS [5] OPTIONS (multiple selections) OUTPUT SPECIFICATIONS Standards & Approvals (must be specified) /N: Without CE or UL /CE: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. ■ DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to our web site.)...

 Open the catalog to page 2
M2ADS-3

MODEL: M2ADS STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (input) Installation Category II (power) Pollution Degree 2 Input 1 or input 2 or output to power input: Reinforced insulation (300 V) Input 1 or input 2 to output: Basic insulation (300 V) RoHS Directive Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (UL 121201, CAN/CSA-C22.2 No.213-17) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1-12) EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm...

 Open the catalog to page 3
M2ADS-4

Specifications are subject to change without notice.

 Open the catalog to page 4

All MG Co., Ltd. catalogs and technical brochures

  1. M2DNY

    3  Pages

  2. M2CDS

    4  Pages

  3. M2CA

    3  Pages

  4. M2BW

    2  Pages

  5. M2BS-16

    5  Pages

  6. M2BS2

    5  Pages

  7. M2BS-16

    5  Pages

  8. M2BD

    7  Pages

  9. M2BC

    8  Pages

  10. M2AVS

    4  Pages

  11. M2AS

    5  Pages

  12. M2AP

    4  Pages

  13. M2AMS

    4  Pages

  14. M2AC

    3  Pages

  15. CNT

    2  Pages

  16. CLSE

    2  Pages

  17. CLSB

    3  Pages

  18. MCN-CON

    1  Page

  19. COP-US

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.