C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components
6Pages

{{requestButtons}}

Catalog excerpts

C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components - 1

Modbus Gateway – Network connection of Modbus RTU fieldbus components

Open the catalog to page 1
C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components - 2

Modbus Gateway With the METZ CONNECT Modbus Gateway MR-GW, Modbus RTU devices are connected to a Modbus TCP network. Up to 32 Modbus RTU Slaves can be connected to the gateway so that Modbus TCP clients can communicate with one or more Modbus RTU Slaves via this gateway. System overview The gateway enables a bidirectional exchange of data between Modbus RTU fieldbus devices and a Modbus TCP master (client). The MR-GW can be operated in two modes. Either as a transparent gateway in Modbus RTU over TCP operating mode or as a protocol converter (Modbus TCP operating mode). The Modbus Gateway...

Open the catalog to page 2
C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components - 3

Modbus TCP Master Devices Modbus RTU Slave Devices Ordering information ACCESSORIES NETWORK COMPONENTS Modbus RTU / Modbus TCP Gateway Modbus RTU / Modbus TCP Gateway 5-port switch with 10/100 BaseT(X) RJ45 Patch cords Cat.6A AWG 26 0.5 m yellow RJ45 connection unit for mounting on support rail RJ45 plug for field assembly Further network components can be found on our website www.metz-connect.com or in our product overview "connection technology for devices, electric cabinets and systems".

Open the catalog to page 3
C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components - 4

Simple configuration Intuitive menu navigation and operation via smartphone, tablet or notebook by responsive design Status monitoring of TCP and RS485 communication Simple device search of METZ CONNECT Modbus RTU devices on the RS485 bus Example of use Interconnection of 2 Modbus RTU lines in an IP network Modbus Fieldbus RTU Line 1 Your benefits connection of max. 32 Modbus RTU Slaves per line simple integration of Modbus RTU Slaves into a Modbus TCP Network Ethernet available throughout the building no limitation to cable lengths reliable and fast communication between automation and...

Open the catalog to page 4
C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components - 5

Modbus RTU I/O Fieldbus module 8 configurable temperature or voltage inputs 4 relay outputs, manual control level 4 triac outputs, manual control level 4 voltage outputs 0-10 V, manual control level MR-TP MR-F-TP 6 analog inputs, 2 relay outputs To capture three 230 Volt current circuits. Current, voltage and power can be measured and determined For monitoring filling levels and leakages, as well as switching magnetic valves 2 digital inputs, 1 relay outputs, changeover contact, manual operation level 4 digital inputs, 2 relay outputs, changeover contact, manual operation level 2 digital...

Open the catalog to page 5
C|Logline - Modbus Gateway – Network connection of Modbus RTU fieldbus components - 6

METZ CONNECT GmbH Im Tal 2 78176 Blumberg Germany Phone +49 7702 533-  0 Fax +49 77  2 533-189 0 info@metz-connect.com www.metz-connect.com METZ CONNECT Zhongshan Ltd. 200 Tornillo Way Tinton Falls, NJ 07712 USA Phone + 1-732-389-1300 Fax + 1-732-389-9066 Ping Chang Road Ping Pu Industrial Park Sanxiang Town Zhongshan City, 528 463 Guangdong Province China Phone +  6 760 86365 055 8 Fax +  6 760 86365 050 8 28, Rue Schweighaeuser 67000 Strasbourg France Phone + 33 38 86 170 73 Fax + 33 38 86 194 73 METZ CONNECT AUSTRIA GmbH c/o German chamber of commerce in Austria Schwarzenbergplatz 5, Top...

Open the catalog to page 6