C|Logline - Intelligent system components with integrated application software - 12 Pages

Add to MyDirectIndustry favorites
C|Logline - Intelligent system components with integrated application software

Catalog excerpts

METZ CONNECT – Intelligent system components with integrated application software Intelligent system components with integrated application software – For automation in buildings, facilities and systems with LON FT5000, BACnet MS/TP and Modbus RTU

 Open the catalog to page 1

METZ CONNECT – Intelligent system components with integrated application software I/O components for automation in buildings, facilities and systems To safely and cost-effectively operate infrastructures in small and large buildings, it is essential that the most vital operational functions run automatically. In turn, this increases the demands placed on the building installation functions. These generally call for a great deal of effort and expense when only implemented with conventional technology. That’s why the field of building automation is increasingly turning to serial bus systems...

 Open the catalog to page 2

METZ CONNECT – Intelligent system components with integrated application software Heating, ventilation and air conditioning applications Radiator/chilled ceiling systems as well as air conditioners/fan convectors with heating or cooling operation can be controlled automatically with individual room controllers. You can further energy savings from automatic room temperature control by connecting motion sensors and shade control. Heating Actuating heating coils Actuating motorized valves (radiators) Measuring room temperatures Actuating pumps (e.g. flow line) Heating Actuating mixer motors...

 Open the catalog to page 3

METZ CONNECT – Intelligent system components with integrated application software Lighting and solar protection applications Energy and operating costs can be reduced with centralized and decentralized control of the lighting. The luminosity is set according to the interior or exterior brightness, or use of the rooms. Lighting scenarios can be saved and created at the touch of a button. With central or decentralized solar protection control, wind, rain and temperature sensors adjust the position of the blinds and slats depending on the weather conditions, and ensure good lighting conditions...

 Open the catalog to page 4

METZ CONNECT – Intelligent system components with integrated application software Intrusion and access control applications Intrusion, espionage or vandalism are a constant threat. This is managed by talking appropriate technical precautions, collecting information about the building and the people inside it. This data acquisition is done electronically using sensors and actuators. Access control Intrusion and access control Counting people Detecting infrared sensors Motion sensors Detecting radar sensors Monitoring window contacts Alarm sensors Detecting vibration contacts (window pane)...

 Open the catalog to page 5

METZ CONNECT – Intelligent system components with integrated application software Overview of applications using the example of an office building Climate control Lighting engineering Fire detection Venetian blinds Energy management Access control Fire protection / fire detection Fire protection, fire detection or smoke extraction constitute one of the most important areas of regulation in building automation. Its main purpose is to protect people and the building itself. By early detection of the seat of a fire, it is possible to avoid “something worse” in most cases. One component of...

 Open the catalog to page 6

METZ CONNECT – Intelligent system components with integrated application software Optimum lighting in all rooms. Dimmers and light scenarios create a homely atmosphere. Since most lighting circuits have a high switch-on load, a special digital mixing module XX-DIO4/2 was developed to actuate these lighting circuits directly using powerful relays. At the same time, the XX-DIO4/2 has digital inputs for connecting the light switches directly for manual operation. This ensures system uptime should the controller not be available at any time. Solar protection Automatic control roller shutters...

 Open the catalog to page 7

METZ CONNECT - Intelligent system components with integrated application software Applications from METZ CONNECT with LON -from the perspective of the applications AREA APPLICATION Actuating heating and cooling valves in summer/winter mode Spatial axis Actuation of 2 three-state drives Air conditioning Application with SNVT_tempa Application with nvihvac_status for 9f:fe:0d:05:40:0a:04:a0 LF-AOP4 11085413 Double three-state controller Application FanspeedCmd Actuation of two solar protection motors 9F:FE:0D:05:28:0A:04:A4 LF-TP 11085913 Solar protection UP/DOWN switch with SNVT_setting...

 Open the catalog to page 8

AREA APPLICATION First reading detection, interlocking communication monitoring Event counter Meter inputs with overflow 90:00:00:00:00:8A:04:81 LF-DI4 1108501319 Input state through SNVT_lev_disc 90:00:00:00:00:8A:04:51 LF-DI4 1108501319 Application with button function Adaptation to a WAGO-LON interface Application to light control in day/night mode 9F:FE:0D:05:0E:0A:04:C8 Lighting control application 9F:FE:0D:05:0E:0A:04:C9 Application to light control in day/night mode Control of 2 striplights with motion sensors Control of 2 striplights with motion sensors and Lighting control panel...

 Open the catalog to page 9

METZ CONNECT - Intelligent system components with integrated application software AREA APPLICATION Actuating heating and cooling valves in summer/winter mode Double three-state controller Application FanspeedCmd Controller optimization by Hand_c Modified manual message 90:00:00:00:00:0A:04:94 General Adaptation to the WAGO-LON interface 90:00:00:00:00:0A:04:95 Actuation of relays with SNVT_lev_disc Locking the manual switch at the mains 90:00:00:00:00:0A:04:93 Lighting control with override by BMS, gates or fire Lighting LF-DO4 as part of a lighting matrix Toggle actuation of relays and...

 Open the catalog to page 10

AREA APPLICATION Solar protection UP/DOWN switch with SNVT_setting First reading detection, interlocking, communication monitoring General Event counter Fire protection Evaluation of limit switches for fire dampers Meter inputs with overflow 90:00:00:00:00:8A:04:81 Input state through SNVT_lev_disc 90:00:00:00:00:8A:04:51 Application with button function 9F:FE:0D:05:3D:0A:04:A0 Adaptation to a WAGO-LON interface 90:00:00:00:00:0A:04:96 Application for electricity meter pulses 9F:FE:0D:05:0E:0A:04:A1 General Application with AND/OR and INV 90:00:00:00:00:0A:04:AF Controller optimization by...

 Open the catalog to page 11

All METZ CONNECT catalogs and technical brochures