1. Catalogs
  2. METZ CONNECT
  3. C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems

C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems

C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems
1 / 10 PagesView full catalog

C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems

Product catalog summary
Overview: METZ CONNECT's BACnet MS/TP components are designed for building automation, facilitating the automatic operation of essential functions such as system control, air-conditioning, ventilation, and lighting. These components use serial bus systems to transmit information between sensors, actuators, and control systems.
Advantages of BACnet MS/TP: The system offers easier planning and installation, high flexibility in building use, and reduced wiring efforts due to decentralized applications. The components are compact, designed for DIN rail mounting, and available in various types, including IP65 housing.
Key Features: The I/O components support master/slave and Token Passing (MS/TP) communication with B-ASC-Profile modules based on the RS485 interface, allowing long-distance data transmission up to 1.2 km at rates up to 500,000 Bit/s.
Modules and Specifications: Various modules are listed with specifications, including digital and analog inputs/outputs, voltage and current ratings, and housing dimensions. For example, the BMT-DI4 module has 4 digital inputs, while the BMT-AI8 module supports 8 analog inputs with selectable temperature curves.
Applications: The modules are suitable for detecting switch states, counting pulses, and integrating into energy control systems. They can be used in decentralized mounting for efficient building automation.
Technical Details: Detailed specifications for each module include input/output types, voltage and current ratings, and schematic diagrams for wiring and installation. The document also provides information on the BACnet IP/BACnet MS/TP Router, which facilitates routing between different BACnet networks.
Conclusion: METZ CONNECT's BACnet MS/TP components offer a robust solution for building automation, providing flexibility, ease of installation, and integration with modern communication standards.
Specifications:
- 1 analog input (0 ... 20 mA)
- 2 analog outputs (0 ... 10 V DC / 5 mA)
- 4 relay outputs (230 V / 6 A)
- 4 digital outputs (24 V / 100 mA)
- Various housing dimensions for different models
- BACnet IP / BACnet MS/TP Router dimensions: 26 x 138 x 70 mm
Procedures and Applications:
- Heating: Actuate heat registers, measure room temperatures, actuate pumps and mixer motors, and control fan coils using various BMT components.
- Air-conditioning: Control motor valves, collect temperature and wind speed data, and detect rain sensors.
- Aeration: Actuate fan motors, control aeration valves, measure volume flow rate, and monitor air pressure and CO2 concentration.
- Lighting and Shading: Switch lights, control sun blinds, and measure brightness and wind speed.
- Fire Alarm Systems: Actuate fire damper motors, detect end positions, and control smoke extraction.
- Burglary and Access Control: Monitor motion detectors, window contacts, and collect sensor data.
- Energy Management: Meter reading, load throw-off, and allocate energy consumption.
- Room Automation: Integrate heating, air conditioning, ventilation, smoke extraction, fire detection, security, and energy control.
Standards and Compliance:
- BACnet is a registered trademark of ASHRAE.
- Compliance with ASHRAE Standard 135 is managed by BACnet International.
Contact Information:
- METZ CONNECT GmbH, Germany
- METZ CONNECT USA Inc., USA
- METZ CONNECT France SAS, France
- METZ CONNECT Austria GmbH, Austria
- METZ CONNECT Zhongshan Ltd., China
- METZ CONNECT Asia Pacific Ltd., Hong Kong
See more

Catalog excerpts

C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-1

BACnet MS/TP components – for automation in buildings, installations and systems

 Open the catalog to page 1
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-2

METZ CONNECT – BACnet MS/TP components I/O components with BACnet MS/TP – For automation in buildings, installations and systems Safe and low-cost operation of infrastructures in large, but also in small, buildings nowadays requires that the most important operational functions such as system control, air-conditioning, ventilation and lighting are executed automatically. However, this also makes higher demands on the functions of the building installation, which can usually be met by conventional technology only with large expenditures. This is why building automation is increasingly using serial...

 Open the catalog to page 2
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-3

8 inputs – analog universally programmable For detecting potential-free switch states, for example electrical end position switches on vent valves or auxiliary contacts of power contactors. For detecting potential-free switch states, for example electrical end position switches on ventilation dampers or auxiliary contacts of power contactors. Depending on how the jumper J has been set, the inputs can be operated as contact and voltage inputs (J-GND jumper) or with activation to GND (A2, J - + 24 jumper). It is suitable for counting S0 counter pulses. This allows very good integration of the module...

 Open the catalog to page 3
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-4

It is suitable for detecting currents and voltages of, for example, active temperature sensors, electrical vent and mixing valves, valve positions, etc. Each input can be set as current or voltage input by DIP switches on the front. For switching electrical components, for example relays, contactors, HVAC valves, etc. Especially suitable for noiseless and cyclic switching (PWM). It can be used as encoder for control variables, for example for electrical vent and mixing valves, valve positions, etc. The BMT-AOP4 allows to switch between automatic and manual mode via the front-side potientiometers....

 Open the catalog to page 4
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-5

11 inputs – digital, 7 inputs – analog 8 outputs – digital, 2 outputs – analog 1 S0 input 4 inputs – digital 2 outputs – digital (relay) It is suitable for accommodating, for example in a room, light switches and room contacts and switching two light strips or as blind control. The control of 2 motorized fire dampers is also possible as are many other applications. The BACnet MS/TP module in IP65 housing with 4 digital inputs and 2 relay outputs with manual control was developed for decentralized switching tasks. It is suitable for accommodating, for example, light switches and window contacts...

 Open the catalog to page 5
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-6

BACnet IP / BACnet MS/TP Router The power supply NG4 supplies regulated direct voltages for supplying power to the respec-tive devices of the product range C|Logline. The device supplies regulated direct voltage 24 V DC at a power of 16 watts. The BACnet IP/BACnet MS/TP Router provides stand-alone routing between BACnet networks such as BACnet/IP, BACnet Ethernet, and BACnet MS/TP – thereby allowing the system integrator to mix BACnet network technologies within a single BACnet internetwork. One 10/100 Mbps Ethernet port and an MS/TP port are used as communication interface to the respective...

 Open the catalog to page 6
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-7

METZ CONNECT – BACnet MS/TP components Application matrix Application examples for I/O components APPLICATION APPROPRIATE DEVICE Actuate heat registers Relay, digital output Measure room temperatures Analog input Actuate pumps (i.e. supply line) Relay, digital output Actuate mixer motors Analog output Actuate motor valves (radiators) TRIAC output, analog output Relay, digital output, TRIAC output Actuate motor valves (radiators) TRIAC output, analog output Collect temperatures Analog input Motor actuation of window flaps Relay, digital output Collect wind speed data Analog input Detect rain sensor...

 Open the catalog to page 7
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-8

METZ CONNECT – BACnet MS/TP components APPROPRIATE DEVICE Collect switch states (i.e. light switches) Digital input Up or down movement of sun blinds (three-point drive) 2 two-level relay outputs Brightness measurement Analog input Collect wind speed (i.e. sun blind protection) Analog input Actuation of motorized window curtains Relays, digital output 2 two-level relay outputs Actuation of fire damper motors Detect end positions of fire dampers Digital inputs Turn-on sprinkler system Relays, digital output Smoke extraction with flap drives Relays, digital output Detect flap position Digital or...

 Open the catalog to page 8
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-9

METZ CONNECT – BACnet MS/TP components APPROPRIATE DEVICE Collect radar sensor data Digital input Alarm sensor Relays, digital output Meter reading (water, gas, current, heat) Digital input, counting input Load throw-off Relays, digital output Motion sensor (turn the light off) Digital input Collect temperatures Analog input Allocate energy consumption to cost centers Counting input Burglary and access control Energy management Digital input S0 input Room automation Heating, air conditioning, ventilation, smoke extarction, fire detection, sequrity and access control, energy controlling, lightning...

 Open the catalog to page 9
C|Logline - BACnet MS/TP components – for automation in buildings, installations and systems-10

METZ CONNECT GmbH is member of the following organizations and associations. METZ CONNECT USA Inc. 200 Tornillo Way Tinton Falls, NJ 07712 USA Phone + 1-732-389-1300 Fax + 1-732-389-9066 METZ CONNECT France SAS 28, Rue Schweighaeuser 67000 Strasbourg France Phone + 33 38 86 170 73 Fax + 33 38 86 194 73 METZ CONNECT Austria GmbH c/o German chamber of commerce in Austria Schwarzenbergplatz 5, Top 3/1 1030 Vienna Austria Phone +  3 1 227 12 64 4 Fax +  3 1 227 12 66 4 METZ CONNECT Zhongshan Ltd. Ping Chang Road Ping Pu Industrial Park Sanxiang Town Zhongshan City, 528 463 Guangdong Province China...

 Open the catalog to page 10

All METZ CONNECT catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.