MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control functions 2 GB internal memory for advanced data recording color LCD TFT display USB port on the front panel with IP54 protection Ethernet port: Modbus TCP, Web Server RS 485 port: ASCII and Modbus RTU Dedicated software for visualization of measurement data Housing for panel mounting or wall mounting 20 CHANNEL FOR MEASURED PROCESS VALUES 18 channels designed to read data from sensors and instruments with digital protocol (HART or Modbus RTU). 2 digital inputs (PULS) for state, pulse or frequency measurements; OC, voltage or NAMUR configuration. HART HART port with power supply for sensors (24 VDC /60 mA), up to 12 sensors in multidrop configuration. Supported rev.4., rev.5., rev.6. Possible configuration as Primary or Secodary Master. Read variables: PV - primary variable, SV – secondary variable, TV third variable, FV - fourth variable. MODBUS RTU (RS485 Port) Sensors or instruments connected in parallel to one twisted pair of wires. Baud rate from 1200 bps to 115200 bps. Available functions: 03 (Read Holding Register) and 04 (Read Input Register), registers in the range 0 ... 65535. Data format: unsigned integer, integer, unsigned long, unsigned long swapped, long, long swapped, floating point, floating point swapped. PULS INPUTS Measurement frequency range 0.001 Hz to 10 kHz. Pulse counting for totalisers. Trac
Open the catalog to page 1MATH CHANNELS 16 math channels can display calculated result based on measured or calculated values. Available functions: addition, subtraction, multiplication, division, square roots. ARCHIVING RESULTS Writing to internal 2GB memory. Text files format with the encrypted checksum, recording to one file (until end or overwrite) or to successive files (24H, week, month). Recording time interval from 3 s to 24 h; possible to define two switched frequencies depending on alarm threshold state. 4 RELAY OUTPUTS, THRESHOLDS ALARM-CONTROL 4 solid-state relay outputs rated at 0,1 A / 60...
Open the catalog to page 2TECHNICAL DATA Type of display: Reading field size: Indication: Keyboard: FRONT PANEL Full color graphic TFT LCD, 272 x 480 px. 43.8 mm x 77.4 mm 3 two-color LEDs (green and red) MPI-D : Membrane, 7 buttons MPI-DN: Membrane, 19 buttons SERIAL PORT RS-485 (1) Transmission protocol Modbus RTU Transmission rate 3 s, 4 s, 5 s, 6 s, 10 s, 12 s, 15 s, 30 s, 1 min Baud rate 1.2, 2.4, 4.8, 9.6 ,19.2, 38,4, 57.6, 115.2 kbps Transmitter address space 1 … 247 Maximum load 32 receivers / transmitters Maximum line length 1200 m Galvanic separation Yes, 250 VAC / 300 VDC Maximum differential voltage A(+)...
Open the catalog to page 3Number of outputs Type of outputs Maximum load current Maximum voltage Wire connection Number of outputs Output current range Maximum voltage beetwen I- and ILoop resistance (for Uloop_power = 24 V) Resolution of C/A converter Accuracy Current loop power Galvanic separation from power supply Wire connection 2,2 mA – 6,5 mA RELAY OUTPUTS 4 Solid-state relays 100 mA (AC/DC) 60 V (AC/DC) MPI-D: two 8-pin screw type terminal blocks, max. cable diameter 1,5 mm2 MPI-DN: spring type terminal block, cable diameter 0,2 mm2 – 1,5 mm2 ANALOG OUTPUT 4-20mA (optional) 1 4-20mA 28 VDC 0 … 500 Ω 16 bit...
Open the catalog to page 4INTERNAL DATA MEMORY Capacity 2 GB (Flash type) Estimated recording time for recording speed every 3s for 16 approximately 400 days measuring channels Recording indication Green-red LED on the front panel Supply voltage Power consumption Wire connection POWER SUPPLY (MPI-D, MPI-DN) 24 VAC (+5% / -10%) 50/60 Hz 24 VDC (15 ... 30 VDC) (any polarity) 6 W max (power supply 24 VDC) 6 VA max (power supply 24 VAC) MPI-D: 3-pin screw type terminal block, max. cable diameter 1,5 mm2 MPI-DN: spring type terminal block, cable diameter 0,2 mm2 – 1,5 mm2 POWER SUPPLY (only MPI-DN) 100 … 240 VAC 50/60 Hz...
Open the catalog to page 5All Metronic AKP catalogs and technical brochures
-
KK DL7
11 Pages
-
FP4 Flow totalizer
6 Pages
-
Metronic Catalague
24 Pages
-
MLOG
2 Pages
-
CONV 485USB-I
2 Pages
-
BC-3N
5 Pages
-
MPI-8E
5 Pages
-
FP-3021
5 Pages
-
FP-3021N
5 Pages
-
FP-3031
5 Pages
-
FP-3031N
5 Pages
-
FP-3011
5 Pages
-
FP-3011N
5 Pages
-
MPI-C
6 Pages
-
MPI-CN
6 Pages
-
MPI-CL
6 Pages
-
MPI-D
5 Pages
-
CONV 485E
3 Pages
-
BC-3
5 Pages
-
DL-7
8 Pages
-
CONV 485USB
2 Pages
-
CONV485E
3 Pages
-
CONV 485USB(I)
2 Pages
Archived catalogs
-
MPI-8, MPI-8/4
6 Pages