Catalog excerpts
PRODUCT CATALOG Process Values □□□□□ □□□□□
Open the catalog to page 1For nearly 20 years, Metronic AKP has specialised in designing and manufacturing devices that measure the compensated flow and consumption of steam and water energy, measure the compensated flow of process gases, record temperature and other physical quantities, and monitor industrial processes. Today, Metronic AKP meters and recorders are used by industrial plants of all sizes. Metering systems based on our equipment operate in power plants, refineries, food processing plants, steel mills, waterworks and gasworks. Our production and design processes are compliant with the ISO 9001-2009...
Open the catalog to page 2MULTI-CHANNEL ELECTRONIC RECORDERS Depending on the version, electronic recorders have between 3 and 42 measurement channels adapted for connecting RTD and TC temperature sensors, resistance and voltage transducers, 0/4-20mA current loop transducers, 0.001Hz to 10kHz pulse transmitters and transducers that share data using the RS-485/Modbus RTU and HART standards (also in multidrop mode). The devices are available in panel-mounted or wall-mounted cases, as well as portable versions (also with own battery power supply). The measurement results may be read locally or transmitted to a computer...
Open the catalog to page 3DL-7 Multichannel electronic data logger 3 to 42 measuring inputs. Up to 100 displayed channels. 7" Touchscreen LCD. Internal memory 2 GB, advanced data recording. IP54 protected USB port on front panel. Ethernet Port: Modbus TCP protocol, RS-485 port: Modbus RTU protocol. Dedicated software for visualisation of measurment results. DL-7 is a modular data recorder, created with a view to best adapt the device to individual customer needs. Each device includes a base module. Depending on the client needs, into device can be installed up to seven, different input / output modules. BASIC MODULE...
Open the catalog to page 4flow PULSE from 0,001 Hz to 10 kHz Remote reading devices by two independent systems ROUTER addresses and ports crossover IP address and port remote data reading Data reading via Internet
Open the catalog to page 5MPI-C, MPI-CL, MPI-CN electronic recorders 16 or 8 universal analog inputs. 8 relay outputs - alarm and control functions. Internal 2GB data memory, advanced data Colour graphic LCD TFT display. IP54 protected USB port on face plate. Ethernet Port: ModbusTCP protocol, www server, RS-485 port: ASCII Dedicated software for visualisation of measurement results. 16 OR 8 UNIVERSAL ANALOG INPUTS Interaction with: ■ transducers with 4-20mA or 0-20mA current loop output, ■ transducers with 0 £1... 5000 CI, resistance ■ transducers with -0,8 V... +0,8 V voltage ■ The inputs are galvanically...
Open the catalog to page 6MPI-D, MPI-DN Multi-channel electronic recorder 20 measuring channels. Interaction with RS-485 / Modbus RTU transducers and devices and HART devices (also in multidrop mode). 2 PULS-type inputs. 16 calculation channels. 4 relay outputs – alarm and control functions. Internal 2GB data memory, advanced data recording. Colour graphic LCD TFT display. IP54 protected USB port on face plate. Communication with master system: Ethernet port and RS-485 port. Dedicated software for visualisation of measurement results. MEASUREMENT CHANNELS 18 channels intended for data readout from Modbus RTU...
Open the catalog to page 7MPI-8, MPI-8/4 Eight- or four-channel electronic recorder 3 device versions: temperature, current, universal (with galvanically separated channels). 8 or 4 analog inputs. Optional 4-20mA analog output. 5 relay outputs – alarm and control functions. Advanced data recording to removable SD/MMC cards. RS-485 port: ASCII and Modbus RTU protocols, optional Ethernet port. Modbus TCP protocol, www server. Dedicated software for visualisation of measurement data. INPUTS Interaction with: RTD sensors – type Pt100, Pt1000 and Ni100 (only in universal and temperature versions), TC sensors – type J, L,...
Open the catalog to page 8MPI-8E Portable 8-channel data logger 8 analog channels Graphic LCD touch screen Internal memory 2 GB USB port on the front panel RS-485 communication port Power supply from internal battery, 230 VAC or 12 VDC (e. g. car lighter socket) Heavy-duty case INPUTS Independent setup for input sensors: RTD sensors (Pt100, Pt200, Pt500, Pt1000) 2- or 3-wire, thermocouples (J, K, T, E, N, B, R, S), transducers with 4-20mA (4-20mA current loop can be supplied from the device) or 0-20mA current loop output, transducers with linear resistance output 0 V ... 100 V , i 0 V ... 1000 V , transducers with...
Open the catalog to page 9FLOW COMPUTERS FOR CALCULATING COMPENSATED FLOW AND THERMAL ENERGY OF STEAM, WATER AND OTHER LIQUID MEDIA AND COMPENSATED FLOW OF PROCESS GASES WITH ELECTRONICALLY REGISTERED RESULTS The FP-30x1(N) series of equipment comprises modern, universal computers for: measuring and calculating the consumption of steam and water in balancing systems, measuring the compensated flow of process gases and other liquid media (glycol, chilled water), measuring dispersed points with the option to operate in computer systems, measuring with recording of results and local readout of results, or periodic...
Open the catalog to page 10FP-3031, FP-3031N Flow computer for calculating compensated flow and thermal energy of steam, water and other liquid media and compensated flow of process gases with electronically registered results Simultaneous consumption calculations in up to three different measurement systems (A, B, C) for separate process lines. Flow and energy balancing (X, Y, Z systems). 10 measurement inputs. Alarm and control functions: 4 alarm and control thresholds for each measurement channel. 4 semiconducting output relays: alarm and control functions, operation in pulse output mode with fixed pulse weight. 1...
Open the catalog to page 11data visualization Orifice Flow Meter Vortex Flow Meter of the heat and flow of steam and condensate
Open the catalog to page 12FP-3011, FP-3011N Flow computer for calculating compensated flow and thermal energy of steam, water and other liquid media and compensated flow of process gases with electronically registered results Simultaneous consumption calculations in up to two different measurement systems (A, B) for separate process lines. Balancing flows and energy. 5 measurement inputs. Alarm and control functions: 4 alarm and control thresholds for each measurement channel. 4 semiconducting output relays: alarm and control functions, operation in pulse output mode with fixed pulse weight. Optional 420mA analog...
Open the catalog to page 13All Metronic AKP catalogs and technical brochures
-
KK DL7
11 Pages
-
FP4 Flow totalizer
6 Pages
-
MLOG
2 Pages
-
CONV 485USB-I
2 Pages
-
BC-3N
5 Pages
-
MPI-8E
5 Pages
-
FP-3021
5 Pages
-
FP-3021N
5 Pages
-
FP-3031
5 Pages
-
FP-3031N
5 Pages
-
FP-3011
5 Pages
-
FP-3011N
5 Pages
-
MPI-C
6 Pages
-
MPI-CN
6 Pages
-
MPI-CL
6 Pages
-
MPI-D
5 Pages
-
MPI-DN
5 Pages
-
CONV 485E
3 Pages
-
BC-3
5 Pages
-
DL-7
8 Pages
-
CONV 485USB
2 Pages
-
CONV485E
3 Pages
-
CONV 485USB(I)
2 Pages
Archived catalogs
-
MPI-8, MPI-8/4
6 Pages