Catalog excerpts
metrvniAPARATURA KONTROLNO - POMIAROWA FP4 FLOW TOTALIZER WITH DATA RECORDING • 2 analog inputs. • 4 solid state relays. • USB port on fornt panel. • Ethernet port and RS-485 port • 4” Touch screen LCD. INTENDED USE: • Measurement of flow and other quantities, e.g. temperature, humidity, pressure. • Operation in dispersed measurement systems with local readings of measurement results. • Grocery, steel, metallurgical, glass-making industry, warehouse and production line control. 2 ANALOG INPUTS Independent setup for input sensors: • transducers with 4-20mA (with optional power supply from device) or 0-20mA current loop output, • RTD sensors (Pt100, Pt200, Pt500, Pt1000), • transducers with 0—2500 Q resistance output, • transducers with -1 V—+1 V or -10 V—+10 V voltage output. 2 PULSE INPUTS • frequency measurement in range 0,01 Hz — 10 kHz, • counting pulses, • tracking and recording of binary signal (shorting or disconnecting). 2 MATH CHANNELS • Available functions: addition, subtraction, multiplication, division, user characteristics. ANALOG OUTPUT • Retransmission of one of the channels as a 4-20mA current loop output signal.
Open the catalog to page 1metrvniAPARATURA KONTROLNO - POMIAROWA TOTALIZERS: • For each input there are available two totalizers L1 and L2. • The counters can be reset manually or they can work automatically: daily , weekly or monthly. • Totalizers T1 and T2 counting the operation time of totalisers. • Frequency of archiving, for counters, from 1 min to 24h. ALARM AND CONTROL SYSTEM: • 4 solid state relays 0,1 A / 60 V. • 2 alarm and control thresholds for each channel. RECORDING MEASUREMENT RESULT: • Recording data to internal 2GB memory, local access to recorded data through USB port on the...
Open the catalog to page 2TECHNICAL DATA Front panel Zarz^dzanie Jakosci^ ISO 9001:2008 Systematycznie monitorowany
Open the catalog to page 3Device version FP4 vi.00 / Data sheet version: 2017-08-30
Open the catalog to page 6All Metronic AKP catalogs and technical brochures
-
KK DL7
11 Pages
-
Metronic Catalague
24 Pages
-
MLOG
2 Pages
-
CONV 485USB-I
2 Pages
-
BC-3N
5 Pages
-
MPI-8E
5 Pages
-
FP-3021
5 Pages
-
FP-3021N
5 Pages
-
FP-3031
5 Pages
-
FP-3031N
5 Pages
-
FP-3011
5 Pages
-
FP-3011N
5 Pages
-
MPI-C
6 Pages
-
MPI-CN
6 Pages
-
MPI-CL
6 Pages
-
MPI-D
5 Pages
-
MPI-DN
5 Pages
-
CONV 485E
3 Pages
-
BC-3
5 Pages
-
DL-7
8 Pages
-
CONV 485USB
2 Pages
-
CONV485E
3 Pages
-
CONV 485USB(I)
2 Pages
Archived catalogs
-
MPI-8, MPI-8/4
6 Pages