FP-3031 - 1

FP-3031N FP-3031 Flow and Energy Computer for Steam, Liquids and Gases with advanced data recording  Handles up to 3 independent installations  10 inputs for process data  User configurable data presentation on color TFT          display Math functions – sum, difference, ratio Advanced data recording for process values and totalisers USB port for data transfer Alarm & control functions, 4 output relays RS485 communication port, ASCII and Modbus RTU protocols Ethernet port, Modbus TCP and server WWW GSM module (option) One or two analog 4-20mA output (option) Software for configuration and recorded data presentation APPLICATION:  Measurement of steam and water in various industrial installations  Measurements of industrial gases and typical or special liquids (like glycol, supercooled water, oils) in heat exchange systems with possibility of local alarming or simple control implementation  Application in distributed control systems with local measurement and data display  Systems with precise data logging for audit trials APPLICATIONS FOR STEAM, LIQUIDS AND TECHNICAL GASES Process values and calculations relevant to a single installation application are grouped in one system named main application. FP-3031 flow computer can handle up to two independent main applications A, B or C. A configuration wizard helps to setup one of possible applications:  the flow and heat of a liquid medium,  the flow and delta heat of a liquid medium in a closed supply-return installation,  the flow and delta heat of a liquid medium in an installation with different supply and return flow rates,  the flow and heat of a steam,  the flow and delta heat in a closed steam-condensate installation,  the flow and delta heat in a steam-condensate installation with different steam and condensate flow rates,  the flow and delta heat in a steam-generating installation with the supplied water flow rate measured,  the flow of a gas. APPLICATION SCOPE FOR STEAM MEASUREMENTS The flow computer performs flow and heat measurement of superheated or saturated steam or water according to IAPWS-IF97 recommendations in the operating range of temperature 0…800 ºC and absolute pressure 0,05…16,52 MPa. Flow and energy measurements of liquids other than water are performed in the range of tabular values entered by user – density and enthalpy as function of temperature. FLOW RATE MEASUREMENT     The flow computer can use: mass flowmeters, volume flowmeters, differential pressure devices with approximation by square root curve, differential pressure devices (orifices and nozzles) according to iteration algorithm ac

Open the catalog to page 1
FP-3031 - 2

In the device there are five measuring inputs enabling connection of sensors and transmitters of various type: 3 x RTD/I - three inputs designed for direct connection of resistive temperature sensors (Pt-100, Pt-200, Pt-500, Pt-1000 or Ni-100, Ni-200,Ni-1000) or 0/4-20 mA current loop transmitters, 4 x I – four inputs enable connection of 0/4-20 mA current loop transmitter, 3 x I/PULS - three inputs enable flow rate measurement from a pulse transmitter (0,001 Hz to 10 kHz) or 0/4-20mA current loop transmitter. ADDITIONAL MEASUREMENTS AND CALCULATIONS Additional measured or calculated values...

Open the catalog to page 2
FP-3031 - 3

TECHNICAL DATA User interface, front panel Display type Readout field size LED indication Keyboard LCD TFT color, 272 x 480 pixels 43.8 mm x 77.4 mm 3 tri-color LEDs, red-orange-green 19 membrane buttons Inputs organization RTD type analog inputs Sensor type Measuring range Sensor connection Wire resistance compensation Maximum resistance of connecting wires A/D converter resolution Accuracy (for Ta = +20 °C) Temperature drift Galvanic isolation between inputs Galvanic isolation to supply voltage Wire connection Pt-100 x K, Ni-100 x K (K = 1..11) K – multiplier, e.g..: for Pt-200 K = 2 -200...

Open the catalog to page 3
FP-3031 - 4

Configuration: OC / contact (default) Voltage(OC) Current (contact) On / off threshold Configuration: input voltage Input resistance On / off threshold Voltage (open) NAMUR configuration High impedance state Low impedance state 12 V 12 mA 2,7 V / 2,4 V >10 k 2,7 V / 2,4 V 12 V 0,4 mA – 1 mA 2,2 mA – 6,5 mA Compensated flow and heat energy measurement Accuracy of compensated steam, water, other liquid or technical gas flow Frequency of measurement and calculation results 4-20 mA analog outputs (optional) Number of outputs Output signal Maximum voltage between I+ and ILoop resistance (for...

Open the catalog to page 4
FP-3031 - 5

Transmission protocol Interface Data buffer Number of opende connections (simultaneously) Connector type LED signaling Modbus TCP, ICMP (ping), DHCP server, http server 10BaseT Ethernet 300 B 4 RJ-45 2 (build in RJ-45 socked) USB port Socket type Version Socket protection class Data format Read/write signaling A type, according to USB standard USB 1.1 IP-54 FAT16 Red/green/yellow LED on front panel Archiving, internal data memory Memory capacity Recording format Recording indication 2 GB (nonvolatile memory) FAT16 (within a limited scope) Green-red USB LED on the front panel FP-3031 and...

Open the catalog to page 5

All Metronic AKP catalogs and technical brochures

  1. KK DL7

    11 Pages

  2. MLOG

    2 Pages

  3. BC-3N

    5 Pages

  4. MPI-8E

    5 Pages

  5. FP-3021

    5 Pages

  6. FP-3021N

    5 Pages

  7. FP-3031N

    5 Pages

  8. FP-3011

    5 Pages

  9. FP-3011N

    5 Pages

  10. MPI-C

    6 Pages

  11. MPI-CN

    6 Pages

  12. MPI-CL

    6 Pages

  13. MPI-D

    5 Pages

  14. MPI-DN

    5 Pages

  15. CONV 485E

    3 Pages

  16. BC-3

    5 Pages

  17. DL-7

    8 Pages

  18. CONV 485USB

    2 Pages

  19. CONV485E

    3 Pages

Archived catalogs