FP-3021N FP-3021 Flow and Energy Computer for Steam, Liquids and Gases with advanced data recording for HART or RS485 / MODBUS RTU sensors Handles up to 2 independent installations 5 channels for HART / Modbus RTU sensors 2 digital channels Alarm & control functions, 4 output relays Analog 4-20mA output (option) Advanced data recording for process values and totalisers User configurable data presentation on color TFT display RS485 communication port, ASCII and Modbus RTU protocols Ethernet port, Modbus TCP and server WWW GSM module (option) Software for configuration and recorded data presentation APPLICATION: Measurement of steam and water in various industrial installations Measurements of industrial gases and typical or special liquids (like glycol, supercooled water, oils) in heat exchange systems with possibility of local alarming or simple control implementation Application in distributed control systems with local measurement and data display Systems with precise data logging for audit trials APPLICATIONS FOR STEAM, LIQUIDS AND TECHNICAL GASES Process values and calculations relevant to a single installation application are grouped in one system named main application. FP-3021 flow computer can handle up to two independent main applications A and B. A configuration wizard helps to setup one of possible applications: the flow and heat of a liquid medium, the flow and delta heat of a liquid medium in a closed supply-return installation, the flow and delta heat of a liquid medium in an installation with different supply and return flow rates, the flow and heat of a steam, the flow and delta heat in a closed steam-condensate installation, the flow and delta heat in a steam-condensate installation with different steam and condensate flow rates, the flow and delta heat in a steam-generating installation with the supplied water flow rate measured, the flow of a gas. APPLICATION SCOPE FOR STEAM MEASUREMENTS The flow computer performs flow and heat measurement of superheated or saturated steam or water according to IAPWS-IF97 recommendations in the operating range of temperature 0…800 ºC and absolute pressure 0,05…16,52 MPa. Flow and energy measurements of liquids other than water are performed in the range of tabular values entered by user – density and enthalpy as function of temperature. FLOW RATE MEASUREMENT The flow computer can use: mass flowmeters, volume flowmeters, differential pressure devices with approximation by square root curve, differential pressure devices (orifices and nozzles) according to iteration algorithm accord
Open the catalog to page 17 CHANNEL FOR MEASURED PROCESS VALUES 5 channels designed to read data from sensors and instruments with digital protocol (HART or Modbus RTU). 2 digital inputs (PULS) for state, pulse or frequency measurements; OC, voltage or NAMUR configuration. HART port with power supply for sensors (24 VDC /60 mA), sensors in multidrop configuration. Supported rev.4., rev.5., rev.6. Possible configuration as Primary or Secondary Master. Read variables: PV - primary variable, SV – secondary variable, TV -third variable, FV fourth variable. Sensors or instruments connected in parallel to one...
Open the catalog to page 2TECHNICAL DATA User interface, front panel Display type Readout field size LED indication Keyboard: LCD TFT color, 272 x 480 pixels 43.8 mm x 77.4 mm 3 tri-color LEDs, red-orange-green FP-3021: 7 membrane buttons FP-3021N: 19 membrane buttons Inputs organization 1 x HART 1 x RS-485 2 x PULS HART Transmission protocol: Implemented features Multidrop mode Loop power Analog line 4-20mA reading Wire connection Master type rev. 4, rev 5, rev.6.; FSK Reading variables PV, SV, TV, FV Retrieve long address Change of short address Yes, up to 12 devices 24 VDC (max 50 mA) No FP-3021: 3-pin screw type...
Open the catalog to page 3FP-3021: two 2-pin screw type terminal blocks, max. cable diameter 1,5 mm2 FP-3021N: spring type terminal block, cable diameter 0,2 mm2 – 1,5 mm2 Wire connection Configuration: OC / contact (default) Voltage(OC) Current (contact) On / off threshold Configuration: voltage input Input resistance On / off threshold Voltage (open) Configuration: NAMUR High impedance state: Low impedance state: >10 k 2,7 V / 2,4 V 12 V 0,4 mA – 1 mA 2,2 mA – 6,5 mA Compensated flow and heat energy measurement Accuracy of compensated steam, water, other liquid or technical gas flow: Frequency of measurement and...
Open the catalog to page 4FP-3021: 6-pin screw type terminal block, max. cable diameter 1,5 mm2 FP-3021N: spring type terminal block, cable diameter 0,2 mm2 – 1,5 mm2 Wire connection Ethernet port Transmission protocol: Interface: Data buffer: Number of opened connections (simultaneously): Connector type: LED signaling: Modbus TCP, ICMP (ping), DHCP server, http server 10BaseT Ethernet 300 B 4 RJ-45 2 (build in RJ-45 socked) USB port Socket type: Version: Socket protection class: Recording format Recording indication A type, according to USB standard USB 1.1 IP-54 FAT16 (within a limited scope) Green-red USB LED on...
Open the catalog to page 5All Metronic AKP catalogs and technical brochures
-
KK DL7
11 Pages
-
FP4 Flow totalizer
6 Pages
-
Metronic Catalague
24 Pages
-
MLOG
2 Pages
-
CONV 485USB-I
2 Pages
-
BC-3N
5 Pages
-
MPI-8E
5 Pages
-
FP-3021
5 Pages
-
FP-3031
5 Pages
-
FP-3031N
5 Pages
-
FP-3011
5 Pages
-
FP-3011N
5 Pages
-
MPI-C
6 Pages
-
MPI-CN
6 Pages
-
MPI-CL
6 Pages
-
MPI-D
5 Pages
-
MPI-DN
5 Pages
-
CONV 485E
3 Pages
-
BC-3
5 Pages
-
DL-7
8 Pages
-
CONV 485USB
2 Pages
-
CONV485E
3 Pages
-
CONV 485USB(I)
2 Pages
Archived catalogs
-
MPI-8, MPI-8/4
6 Pages