BC-3N

BC-3N

BC-3N

Product catalog summary
Overview: The BC-3N and BC-3 are batch controllers designed to manage up to three batching systems with one or two-stage batching modes. They offer flexibility in dispenser operation, measurement inputs, and output controls.
Specifications:
  • Batching Systems: Supports up to three systems (A, B, C).
  • Batching Modes: One or two-stage modes available.
  • Measurement Inputs: Five inputs (2 x 0/4-20mA, 3 x pulse or 0/4-20mA).
  • Relay Outputs: Four SSR outputs for valve control or alarms.
  • Analog Outputs: Optional 4-20mA outputs for valve control.
  • Data Recording: 2GB internal memory with USB and Ethernet access.
  • Communication: RS485, Ethernet, and USB ports with various protocols.
  • Power Supply: 24 VAC/VDC for BC-3; 24 VAC/VDC and 230 VAC for BC-3N.
Measurement Inputs: The device includes five inputs for connecting current loop transducers or pulse transducers, suitable for flow measurement and other values.
Relay and Analog Outputs: Four SSR outputs are available for controlling valves or alarms, with optional analog outputs for valve control.
Flow Measurement: Compatible with various flow meters using 4-20mA, pulse, or frequency outputs.
Batching Modes: Offers one-step and two-step modes, with learning algorithms to enhance accuracy.
Launching Modes: Dispensers can be activated individually or sequentially.
Totalisers and Archiving: Two totalisers per input and dispenser, with data archived every 15 minutes.
Alarms: Triggered by overrun metering, flow issues, or unauthorized flow start.
Communication: Supports RS485, Ethernet, and USB with protocols like Modbus TCP and RTU.
Technical Data:
  • Display: LCD TFT color, 272 x 480 pixels.
  • Inputs: 0/4-20mA and pulse inputs with specific configurations.
  • Outputs: 4-20mA analog outputs and binary outputs with specific load capacities.
  • RS485 and Ethernet Ports: Support various protocols and configurations.
  • USB Port: Type A, USB 1.1, with IP-54 protection.
  • Power Supply: Various voltage options with specific consumption rates.
Physical Specifications:
  • BC-3 Casing: Panel surface, nonflammable plastic, IP-54 front protection.
  • BC-3N Casing: Wall mounting, ABS, IP-54 protection.
  • Dimensions and Weight: Specific dimensions and weights for both versions.
Environmental Conditions: Operates within 0 to +40°C, with storage temperatures from -20 to +80°C and relative humidity up to 75%.
See more

Catalog excerpts

BC-3N-1

BC-3N, BC-3 Batch controller  Up to three (A, B, C) batching systems  Batching mode: one or two-stage  Dispensers may be switched on: individually or sequentially  5 measurement inputs  4 relay outputs  Up to 2 analog 4-20mA outputs (option)  Valve control using relay output or analog output 4-20mA  Two totalisers for each input and dispenser  Advanced data recording, 2GB internal memory  USP port on front panel  Ethernet port, server WWW, Modbus TCP  RS485 communication port, ASCII and Modbus RTU protocols  Two housing types: panel and wall-mounting MEASUREMENT INPUTS In the device there are five measuring inputs:  2 x I, two inputs enable connection of 0/4-20mA current loop transducers,  3 x I/PULS, three inputs enable connection of pulse transducer (0,001 Hz to 10 kHz) or 0/4-20mA current loop transducer. Inputs can be used to measure flow relating to batching process or any other values. RELAY OUTPUTS Device is equipped with four SSR outputs 0,1 A/60 V. They can be used to control the valves or alarm signalization. ANALOG OUTPUT 4-20mA Device may be optionally equipped with two analog outputs for controlling valves. FLOW MEASUREMENT The device may work with flow meter of any type (e.g. ultrasonic, vortex, electromagnetic) using:  4-20mA or 0-20mA output signal proportional to actual flow rate,  pulse output with constant weight per pulse,  frequency output proportional to actual flow rate. BATCHING MODES There are two modes:  one-step mode,  two-step mode: in case relay outputs are used to control, two valves are being controlled: main (coarse) valve, which operates at the beginning of metering process only and fine adjustment valve, which operates all the time; in such a case two relay outputs are used. On the other hand, when current output is used to control, only one valve is being controlled, and the value of the current defines opening/ closing grade of the valve. Batch controller have implemented learning algorithm

 Open the catalog to page 1
BC-3N-2

LAUNCHING MODES Batching process may be activated in either mode:  individual - each of the dispensers A, B or C is switched on separately by the user,  sequential – once dispenser "A" has been switched on, two other units (B & C) are automatically switched on upon the set time delay. TOTALISERS Two totalisers may be configured for each IN1 … IN5 input and each dispenser. The totalisers, which serve measuring inputs, count all the time, while those serving dispensers count only when metering process is ON. Selected counters are archived with a frequency of every 15 min. ARCHIVING RESULTS ...

 Open the catalog to page 2
BC-3N-3

TECHNICAL DATA User interface, front panel Display type Readout field size LED indication Keyboard LCD TFT color, 272 x 480 pixels 43.8 mm x 77.4 mm 3 two-color LEDs, red-orange-green 19 membrane buttons Inputs organization Signal type Transmitter connection Input resistance Transmitters supply A/D converter resolution Accuracy (Ta = 20 °C) Temperature drift Galvanic isolation between inputs Galvanic isolation to supply voltage Signal type 0-20mA or 4-20mA Passive transmitter (supplied from measuring loop) or active converter 100  ±10% 24 V DC / max 22 mA 18 bits ±0,1% of the range (typical...

 Open the catalog to page 3
BC-3N-4

Accuracy Current loop supply Galvanic isolation to supply voltage 0,5% of the range External or from internal unit supply 24 V DC / 22 mA 400 VAC Binary outputs Number of outputs Outputs type Maximum load current Maximum voltage Galvanic isolation 4, mutually separated Semiconductor relays 100 mA DC/AC 60 V DC/AC 400 VAC RS485 serial port Maximum load Maximum line length Maximum differential voltage A(+) – B(-) Maximum total voltage A(+) – „ground” or B(-) – „ground” Transmitter minimum output signal Receiver minimum sensitivity Minimum impedance of data transmission line Internal terminating...

 Open the catalog to page 4
BC-3N-5

BC-3 casing - dimensions Casing type For panel surface, nonflammable plastic material „Noryl” Dimensions (height x width x depth) 96 mm x 192 mm x 63,5 mm Housing depth with terminals (without extra space for ca. 72 mm cables) +1,1 +0,6 Panel cut-out dimensions 186 mm X 92 mm Panel maximum thickness 5 mm Weight ca. 0,7 kg Protection class from the front panel IP-54 Protection class from the rear panel IP-30 BC-3N casing - dimensions Casing type Dimensions (height x width x depth) Weight Protection class BC-3 BC-3N Wall mounting, ABS 217 mm X 257 mm X 125 mm (without cable glands) 247 mm X 257...

 Open the catalog to page 5

All Metronic AKP catalogs and technical brochures

  1. KK DL7

    11  Pages

  2. MLOG

    2  Pages

  3. CONV 485USB-I

    2  Pages

  4. MPI-8E

    5  Pages

  5. FP-3021

    5  Pages

  6. FP-3021N

    5  Pages

  7. FP-3031

    5  Pages

  8. FP-3031N

    5  Pages

  9. FP-3011

    5  Pages

  10. FP-3011N

    5  Pages

  11. MPI-C

    6  Pages

  12. MPI-CN

    6  Pages

  13. MPI-CL

    6  Pages

  14. MPI-D

    5  Pages

  15. MPI-DN

    5  Pages

  16. CONV 485E

    3  Pages

  17. BC-3

    5  Pages

  18. DL-7

    8  Pages

  19. CONV 485USB

    2  Pages

  20. CONV485E

    3  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.