MEDICAL& SCIENCE INDUSTRIAL & ENERGY RESEARCH & DEVELOPMENT AEROSPACE & • MARINE &
Open the catalog to page 1contents Overview Introduction Compact or remote installation LTM Specification Instrument / Display Specification GTM Specification Configurations Dimensions a Rugged Versatile Compact or Remote metri ltm & gtm series Industrial Turbines flow meters for accurate continuous volumetric measurement of liquids and gases • High temperature option up to 350°C • Selection of flow instruments & displays for compact or remote installation • Choice of outputs including pulse, 4-20 mA • ATEX rated option • Wide range of line sizes • Accurate measurement with excellent linearity & repeatability • Rugged...
Open the catalog to page 3ACCU RATE L IQUID AND GAS FLOW M E ASUR EMENT Manufactured in the UK by icenta Controls and result of over 30 years of development, the IC-LTM/GTM series of industrial in-line turbine flow meters provide a high standard of accuracy and reliability in a large number of volumetric flow measurement applications. IC-LTM meters are available in a range of nominal sizes from 6 to 150 mm, offering standard Liquid flow ranges from as low as 0.028 to 0.28 m3/hr (0.5 to 5 l/min) up to 55 to 550 m3/hr (920 to 9200 l/min); each individual meter has a specific standard flow range of 10:1 with an extended option...
Open the catalog to page 4compact or remote installation We offer a comprehensive selection of flow instruments & displays for compact or remote installation. Metri liquid turbine meters can be combined with the following products; type fiiio panel mount FLOW TRANSMITTER • 2-line, 16-character LCD display • Total / accumulated total / flow rate • Frequency input • Open collector pulse output • 4-20 mA output • Alarm set points (2 relays) field and panel mount flow transmitters type FI210 / FI220 FLOW TRANSMITTERS • Rugged diecast aluminium construction • Choice of powered (FI210) or battery powered (FI220) • 2-line, 12-character...
Open the catalog to page 5Process connection BSPP (parallel) & BSPT (taper) female threaded, DIN & ANSI flanged; other on request eg PNXX, tri-clamp, NPT, RJT, Flange rating PN 16, 40, 100 (BS EN 1092-1); ANSI 150, 300, 600 RF (ANSI B16.5) Slip on and Butt Weld type Compatibility Solids free and partially contaminated liquids including water, chemicals, hydrocarbons, mineral oils, alcohols Flow range (liquid) 0.028 to 550 m3/hr (0.5 to 9166 l/min), various ranges (see section 6 Configuration) Flow direction Single; bi-directional on certain sizes Operating temperature Standard: -40 to 230°C High: -40 to 350°C (excludes...
Open the catalog to page 6Process connection BSPP (parallel) & BSPT (taper) female threaded, DIN & ANSI flanged; other on request eg PNXX, tri-clamp, NPT, RJT, Weco, Autoclave Flange rating PN 16, 40, 100 (BS EN 1092-1); ANSI 150, 300, 600 RF (ANSI B16.5) Slip on and Butt Weld type Compatibility Dry and Wet gases compatible with 430, 174PH and Duplex stainless steels (other materials available on request) Flow range (gases) 0.44 - 2000 m3/hr *See Notes 1. & 2 (Section 7 Configurations) Flow directron Single; bi-directional on certain sizes Operating temperature Standard: -20 to 150°C shielded ball bearings High: -40 to...
Open the catalog to page 7Configurations versatile configurations Ordering information: IC-LTM flow meter(Liquid Configurat iartt;ntntae adapMedor ne-^fomiseir tcr-eeet your requirements -LPM Nomiaal size & flow raate (based oa H2O @ 20°C) Other sizes and flow rates on request Flow rante: standard/extended (see above for values) Flow Dirertioa Process roaaertioa BSPP (parallel) male BSPT (taper) female Other on request (eg PNXX, tri-clamp, NPT, RJT etc) Ball Race General purpose Output / display IC-MV-PO pulsed output module A IC-MV-AN analogue output module D Flow transmitter / display (specify separately) No instrument...
Open the catalog to page 8Ordering information: IC-GTM flow meter (Gas Meter) Configurations can be adapted or customised to meet your requirements Ordering information: IC-GTM flow meter (Gas Meter) IC-GTM Nominal size & flow range Standard Operating Range Maximum operating Repeatable Range* 0Z0Z Other sizes and flow rates on request Flow range: standard/extended (see above for values) S Extended Flow Direction S B Bi-directional Process connection A BSPP (parallel) male BSPT (taper) female Other on request (eg PNXX, tri-clamp, NPT, RJT etc) Bearings B Ball Race O Other Max operating temperature S Standard: -20 to 150°C...
Open the catalog to page 9installation Asymmetric flow conditions can cause errors in turbine flow meter performance. It is therefore essential if these errors are to be reduced the flow meter should be installed with the appropriate upstream / downstream pipe lengths. The meter can be installed either horizontally or vertically with flow rising and only with a full pipe. For best practice, allow at least 10 diameters of straight pipe run upstream and 5 diameters of straight pipe run downstream of the flow meter installation. Greater straight run lengths may be required when installed close to bends, elbows and valves...
Open the catalog to page 10The Woodford centre Lysander Way Old Sarum Park Salisbury +44 (0)844 543 0844 Metri is a division of Icenta Controls Ltd
Open the catalog to page 124 Pages