Electrical Equipment / Machine / Switchboard safety MI 3340 AlphaEE XA Electrical Equipment / Machine / Switchboard safety The new cutting-edge AlphaEE XA, is designed with an innovative housing that redefines the ease and comfort of electrical equipment testing. The instrument is engineered for robust performance and perfect balance, the AlphaEE XA ensures effortless one-handed operation, making it an indispensable tool for professionals on the go. The user-friendly interface provides the flexibility of a touch screen or function keys catering to your preferred method of operation. This dual option enhances usability, ensuring a seamless experience whether you're conducting routine checks or detailed diagnostics.Designed with service organizations in mind, the AlphaEE XA boasts specialized measuring functions that cater to a wide range of applications. It offers both periodic testing and testing after repair with pre-defined AutoSequences and single measurements for on-the-spot servicing, providing unparalleled versatility. AlphaEE XA boosts the future of electrical equipment testing, with its unparalleled convenience, advanced functionality, and exceptional performance, all encapsulated in a sleek, user-centric design. MEASURING FUNCTIONS • EN 50678 / EN 50699 • Visual inspections; • Auto test (Continuity + Insulation resistance + Alternative leakage) • Continuity of protective earth 200mA; • Insulation Resistance (Riso, Riso-S) 50V, 100V, 250V, 500V; • Protective conductor current (Direct, Residual, Alternative); • Touch leakage current (Direct, Alternative); • Leakage current produced by a floating input, PE current (Direct, Residual); • Leakage current produced by a floating input, Touch current (Direct); • Leaks & Power (Itou, Idiff, P, S, Q, PF, THDu, THDi, CosØ, I, U); • Point to Point Leakage current (Direct) • Power (P, S, Q, PF, THDu, THDi, CosØ, I, U); • PRCD test, (2 pole, 3 pole, K/ Di (varistor), S (3pole)), S+; • PRCD test (PE conductor, Open conductor, PE probe); • RCD test (type A, AC, B, B+, F); • IC-CPD test (EV-RCD, PE conductor); • Voltage, SELV/PELV; • Socket test; • Polarity / Active polarity test; • EVSE Diagnostic test; • Clamp current;* • Functional inspections. • Ergonomic housing: Experience ultimate convenience with our ergonomic housing, designed for effortless single-handed operation. • Li-Ion battery: Enjoy extended use and rapid recharging with Li-Ion battery, leveraging advanced Li-Ion technology for longer operation times and quicker charge cycles. • Pre-defined AUTOSEQUENCE®s: According to: EN 50678, EN 50699, EV-Cables, P-RCDs, Devices with Floating inputs, Audio/video, information and communication technology EN 62368-1. • Insulation resistance test (50V, 100V): Lower test voltages at insulation resistance tests make it easy to safely evaluate sensitive electronic equipment or devices that may be damaged by higher test voltages. • IC-CPD: Easily test Mode 2 and Mode 3 EV cables with the help of supported compatible adapters. • Active polarity test: Ensure flawless functionality with our active polarity test, designed to verify devices requiring mains voltage for operation, including P-RCD switches, smart extension leads, and electric vehicle charging cables. • Colour touch screen: Offers users a quick overview and effortless parameter adjustment, enhancing both efficiency and user experience. • Auto Continuity: The Auto start feature enables a rapid and efficient assessment of devices with a larger number of metal parts that require inspection. • Socket test: a socket test function empowers users to troubleshoot connection points effectively. With this feature, you can verify mains voltage, and the integrity of "L / N / PE" wiring, ensuring reliable and accurate confirmation. • Standby power: Testing of Standby power (Commission regulation No 2023/826). • Support for PRCD testing: Support for all types of PRCDs, including 2-pole, 3-pole, K/Di (varistor), S (3 pole) and testing with the PE probe. • BlackBox protocol: The primary purpose of the Black Box protocol is to enable execution of Single tests and AutoSequences via remote applications. • PC SW Metrel ES Manager: Enables creation of test structures, user-defined AUTOSEQUENCE®s, professional test reports and data transfer for archiving. • aMESM Android SW: Enables QR
Open the catalog to page 1FUNCTION Continuity / Protective earth resistance 1 Continuity (200 mA) Insulation Resistance (Riso, Riso-S) 2 Insulation resistance, Insulation resistance – S (50 V, 100 V) 2 Insulation resistance, Insulation resistance – S (250 V, 500 V) Output voltage Substitute Leakage Current, Substitute leakage current – S 3 Substitute Leakage Current, Substitute leakage current – S Cont+Ins+Sub MEASURING RANGE ±(2 % of reading + 2 D) ± 3 % of reading ± 5 % of reading ± 5 % of reading Riso Riso - S Riso Riso - S ±(3 % of reading + 2 D) ± 5 % of reading ± 10 % of reading Refer to technical specification...
Open the catalog to page 2Power (reactive) ±(5 % of reading + 5 D) ± 5 % of reading ± 5 % of reading ± 5 % of reading Power factor Total Harmonic Distortion (voltage) Total Harmonic Distortion (current) Leak’s & Power 5 Touch leakage current Power (active) ±(5 % of reading + 5 D) ± 5 % of reading ± 5 % of reading ± 5 % of reading Power (apparent) ±(5 % of reading + 5 D) ± 5 % of reading ± 5 % of reading ± 5 % of reading Power (reactive) ±(5 % of reading + 5 D) ± 5 % of reading ± 5 % of reading ± 5 % of reading Power factor Total Harmonic Distortion (voltage) TEST PRINCIPLE Differential leakage current PRCD test 7 Trip-out...
Open the catalog to page 3EV RCD test 11 Trip-out time TEST CURRENT a.c. pulse d.c. (A) Trip-out current TEST PRINCIPLE EVSE Diagnostic test (A 1632) This test is performed in combination with an external test adapter / instrument. For technical specification refer to A 1632 eMobility Analyser Instruction manual. MEASURING RANGE MEASURING RANGE ±(5 % of reading + 10 D) ±(5 % of reading + 5 D) ±(5 % of reading + 5 D) ±(5 % of reading + 5 D) ±(5 % of reading + 5 D) PE conductor (EV RCD) 9 PE conductor (I test = Standard) TEST PRINCIPLE Normal … test voltage (230 V a.c.) Active … test voltage (mains voltage) FUNCTION Clamp...
Open the catalog to page 44 Pages
6 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
8 Pages
8 Pages
8 Pages
8 Pages
56 Pages
2 Pages
2 Pages
64 Pages
72 Pages
272 Pages
1 Page
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
28 Pages
4 Pages
2 Pages