MI 3295 Step Contact Voltage Measuring System EN
2Pages

{{requestButtons}}

Catalog excerpts

MI 3295 Step Contact Voltage Measuring System EN - 1

Earth testers MI 3295 Step Contact Voltage Measuring System High Voltage Insulation / Continuity / Earth The MI 3295 Step Contact Voltage Measuring System is a voltage measuring system intended for testing and verification of protective earthing of power stations, substation and other power systems. The system consists of Station for current generation and autonomous voltage Meter. Due to high test current (up to 55 A) and effective noise cancellation the MI 3295 ensures very accurate and stable measurements of Step and Contact Voltages with the resolution down to 10 µV. A few voltmeters can be used simultaneously for faster analysis of voltage distribution around the tested object. All test results and parameters can be saved into the instrument’s memory for further downloading, analysis and test report printing with the help of the PC SW Metrel ES Manager or HVLink PRO. MEASURING FUNCTIONS • Step voltage; • Contact voltage; • Specific earth resistance; • Earth resistance; • Potential; • Leakage current. • Accurate: high accuracy of the measurements due to a high current of up to 50 A and effective suppression of noise. • Noise immunity: excellent immunity even against changing earth currents. • Autonomous Step Voltage meter: no need for long potential leads; a few meters can be used simultaneously. • Safe: high safety due to low output voltage (55 V). • Low weight: the weight of the Station is 29.5 kg only. • Memory: up to 1000 test results can be saved into the 3-level internal memory of the system. • PC SW Metrel ES Manager or HVLink PRO included in the standard set enables downloading and analysis of results and printing of test reports. Measurement of protective earthing of: • Power stations; • Substations; • Distribution towers; • Other power systems. STANDARDS Functionality • ANSI/IEEE Std 81; • EN 61557-5; • RAT 2008; • HD 673 N4 Electromagnetic compatibility • EN

Open the catalog to page 1
MI 3295 Step Contact Voltage Measuring System EN - 2

TECHNICAL SPECIFICATION ORDERING INFORMATION Measuring range Step voltage, Contact voltage (measuring range Um) ±(2 % of reading + 2 digits) ±(2 % of reading + 2 digits) ±(2 % of reading + 2 digits) ±(2 % of reading + 2 digits) ±(2 % of reading + 2 digits) calculated value* ±(3 % of reading + 5 digits) ±(3 % of reading + 3 digits) ±(2 % of reading + 5 digits) ±(2 % of reading + 5 digits) ±(2 % of reading + 5 digits) ±5 % of reading) Calculated value, consider accuracy of Resistance to earth function. Step voltage, Contact voltage (calculated measuring range U) Test current Test voltage Test...

Open the catalog to page 2

All METREL catalogs and technical brochures