1. Catalogs
  2. METREL
  3. MI 3205 TeraOhmXA 5kV EN

MI 3205 TeraOhmXA 5kV EN

MI 3205 TeraOhmXA 5kV EN

MI 3205 TeraOhmXA 5kV EN

Product catalog summary
Measuring Functions
  • Insulation Measurement
  • Diagnostic Tests: Polarization Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD)
  • Step Voltage Test
  • Withstanding Voltage Test (DC) up to 5 kV
  • Voltage and Frequency Measurement up to 550 V TRMS
Key Features
  • Insulation resistance measurement up to 15 TΩ
  • Adjustable test voltage from 50 V to 5 kV in 50 V and 100 V steps
  • Programmable timer and capacitance measurement
  • Fast charging rate for capacitive loads
  • Automatic discharge of test object post-measurement
  • Guard terminal and high voltage breakdown detection
  • Custom defined tests and auto adjustment function
  • Results available in numerical and graphical form
  • PC software HVLink PRO for data analysis and report printing
  • Isolated RS232, USB communication ports, and BT interface
  • High EM interference protection and CAT IV / 600 V rating
  • Operates at altitudes up to 3000 m
  • Powered by a high power Li-ion battery pack or mains
Applications
  • Power transformers and measuring transducers in distribution networks
  • Insulation resistance testing of rotating machinery and cables
  • Production line testing and maintenance
  • Troubleshooting insulation problems
  • High voltage generators, surge arrestors, and varistors
Standards
  • Electromagnetic Compatibility: EN 61326 class A
  • Safety: EN 61010-1, EN 61010-2-030, EN 61010-2-033, EN 61010-031
Technical Specifications
  • Insulation resistance range: 0.01 MΩ to 15 TΩ with varying resolutions and accuracies
  • Test voltage range: 0 V to 4.99 kV
  • Insulation leakage current measurement: 0.00 nA to 5.00 mA
  • Capacitance measurement: 20.0 nF to 50.0 µF
  • True RMS voltmeter range: 5 V to 550 V
  • Frequency measurement: 10 Hz to 500 Hz
  • Power supply: 90-260 VAC or 14.4 VDC Li-Ion battery
  • Display: Matrix LCD with backlight
  • Dimensions: 345 x 160 x 335 mm, Weight: 6.5 kg
Ordering Information
  • Standard and Euro sets available with various accessories including shielded test leads and crocodile clips
See more

Catalog excerpts

MI 3205 TeraOhmXA 5kV EN-1

Professional insulation testing with powerful diagnostic tools MI 3205 TeraOhmXA 5kV High Voltage Insulation / Continuity / Earth MI 3205 TeraOhm XA 5kV is a portable battery (Li-ion) or mains powered test instrument with excellent IP protection (IP65 case closed and IP54 case open), intended for diagnosing of Insulation Resistance by using high test voltages of up to 5 kV. It is designed and produced with the extensive knowledge and experience acquired through many years of working in this field. MEASURING FUNCTIONS • Insulation Measurement; • Diagnostic Test (PI, DAR, DD); • Step Voltage Test; • Withstanding Voltage Test (DC) up to 5 kV; • Voltage and frequency measurement up to 550 V TRMS. KEY FEATURES • Insulation resistance up to 15 TΩ; • Adjustable test voltage (50 V...5 kV) 50 V and 100 V step; • Programmable timer; • Capacitance measurement; • Charging rate for capacitive load < 1,5 s / µF at 5 kV; • Short circuit / charge current > 6 mA; • Automatic discharge of test object after completion of measurement; • Guard terminal; • High voltage breakdown detection; • Custom defined tests; • Auto adjustment function; • Measurement results in numerical and graphical form; • PC software HVLink PRO for downloading and analyzing of the test results and test report printing; • Isolated RS232 and USB communication ports, BT interface; • High quality accessories including shielded test leads in standard set; • High EM interferences protection: Input AC current noise rejection (1 mA@300 V) and additional averaging of the result (5, 10, 30, 60); • CAT IV / 600 V; • Increased working nominal altitude to 3000 m; • High power Li-ion battery pack (14.8V, 4.4Ah); • Mains and rechargeable battery power supply. APPLICATION • Power transformers; • Measuring transducers in distribution networks; • Testing insulation resistance of rotating machinery and cables; • Production line periodic testing and maintenance; • Troubleshooting and analysis of all kinds of insulation problems; • High voltage generators; • Surge arrestors and varistors. STANDARDS Electromagnetic compatibility • EN 61326 class A Safety • EN 61010-1 (instr

 Open the catalog to page 1
MI 3205 TeraOhmXA 5kV EN-2

TECHNICAL SPECIFICATION ORDERING INFORMATION Measuring range Insulation resistance ±(5% of reading + 3 digits) ±(5% of reading + 3 digits) ±(5% of reading + 3 digits) ±(5% of reading + 3 digits) ±(5% of reading + 3 digits) ±(5% of reading + 3 digits) ±(15% of reading + 3 digits) ±(15% of reading + 3 digits) Test voltage Insulation leakage current Dielectric absorption ratio (DAR) Power supply Matrix LCD with backlight, 320 x 240 dots Overvoltage category Protection class Double insulation IP 54 (case open) COM port OPTIONAL ACCESSORIES Photo 10 kV shielded test lead, 8 m, 2 pcs (black, red) Guard...

 Open the catalog to page 2

All METREL catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.