MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests. MEASURING FUNCTIONS • Insulation resistance with DC voltage from 50 V to 1000 V; • Varistor test; • Continuity of PE conductors with 200 mA DC test current with polarity change; • Continuity of PE conductors with 7 mA test current without RCD tripping; • Line/Loop impedance combined also in one function Z AUTO; • Loop impedance with Trip Lock RCD function; • TRMS voltage and frequency measurements; • Phase sequence; • Power and THD measurement (up to the 12th harmonic); • RCD testing (general and selective, type AC, A, F, B, B+, MI RCD, EV RCD, PRCD, PRCD-K, PRCD-S); • Earth resistance (3-wire and 2-clamps method); • Specific earth resistance with Ro-adapter (option); • TRMS leakage and load currents (option); • First fault leakage current (ISFL); • Testing of Insulation Monitoring Devices (IMDs); • Illumination (option); • High resolution Loop impendance (mn) (option); • EVSE AUTO SEQUENCES and function inspections. • Determining location of cables (option); • QR and/or barcode scanner support (option). • Predefined profile dependent AUTO SEQUENCEs. • Predefined Automatic tests: Auto TT (U, Zln, Zs, Uc); Auto TN/RCD (U, Zln, Zs, Rpe); Auto TN (U, Zln, Zlpe, Rpe); Auto IT (U, Zln, Isc, Isfl, IMD). • Built-in help screens for referencing on site. • Built-in fuse tables for automatic evaluation of the line / loop impedance result. • Monitoring of all 3 voltages in real-time. • Automatic polarity reversal on continuity test. • Automated RCD testing procedure. • Automated Impedance testing procedure (Z AUTO). • Functional inspections. • Measurement filtering according to the selected area group. • Built-in charger and rechargeable batteries as standard accessory. • BT communication with PC, Android tablets and smart phones via built-in BT. • PC SW Metrel ES Manager (structure and report creation, data upload/download). • Optional aMESM Android APP (structure and report creation, data upload/download). • Testing of TT, TN and IT systems; • Testing of single and multiphase systems; • Initial and periodic testing of domestic installations; • Maintenance; • Lightning installations; • Medical installation testing; • Fire brigades, military and police vehicles; • Construction sites; • Mobile Video/Audio, Concert Halls, Fair Playground; • Electrical Vehicle Supply Equipment (EVSE) testing. STANDARDS Functionality • EN 61557; DIN 5032 Other reference standards for testing: • IEC/EN/HD 60364-4-41; IEC/EN 61008; IEC/EN 61009; BS 7671; AS/NZ 3017 Electromagnetic compatibility (EMC): • IEC/EN 61326-1 Safety • IEC/EN 61010-1; IEC/EN 61010-031; IEC/EN 61010-2-030; IEC/EN 610102-032;
Open the catalog to page 1TECHNICAL SPECIFICATION ORDERING INFORMATION Function CONTINUITY Test Current 7 mA INSULATION RESISTANCE IMPEDANCE Zline L-L, L-N Ipsc VOLTAGE TRMS CURRENT TRMS, AC with A 1018 TRMS, AC/DC with A 1391, range=40 A TRMS, AC/DC with A 1391, range = 300 A Specific earth resistance Standard set MI 3152 ST • Instrument MI 3152 EurotestXC • Plug commander, 1.5 m • Test lead, 3 x 1.5 m • Power supply adapter + 6 NiMH rechargeable batteries, type AA • Test probe, 3 pcs (blue, black, green) • Crocodile clip, 3 pcs (blue, black, green) • Earth set 20 m • RS232 - PS/2 cable • USB cable •...
Open the catalog to page 2All METREL catalogs and technical brochures
-
MI 3114 PV Tester
2 Pages
-
MI 3215 TeraOhmHP 15 kV
2 Pages
-
MI 3211 TeraOhmHP 10 kV
2 Pages
-
MI 3115 PV Analyser EN
2 Pages
-
MI 3132 EV Tester EN
3 Pages
-
MI 3365 25A OmegaEE XD EN
8 Pages
-
MI 3365 F OmegaEE XD EN
8 Pages
-
MI 3365 M OmegaEE XD EN
8 Pages
-
MI 3365 OmegaEE XD EN
8 Pages
-
MI 3360 OmegaGT XA guide EN
56 Pages
-
MD 9210 Mini Clamp Meter EN
2 Pages
-
Medical Facilities catalogue
64 Pages
-
Building Facilities catalogue
72 Pages
-
General catalogue 2023 EN
272 Pages
-
MI 3299 HV demo BOX
1 Pages
-
SW 1203 Metrel SDK EN
3 Pages
-
MI 3360 OmegaGT XA EN
4 Pages
-
MI 3325 MultiServicerXD EN
4 Pages
-
MI 3394 CE MultiTesterXS EN
2 Pages
-
MI 3394 CE MultiTesterXA EN
3 Pages
-
MI 6601 MediTest EN
4 Pages
-
MI 3110 EurotestIM EN
2 Pages
-
A 1722 PRCD adapter EN
2 Pages
-
A 1632 eMobility Analyser EN
2 Pages
-
A 1532 XA EVSE adapter EN
2 Pages
-
A 1532 EVSE adapter EN
2 Pages
-
MI 2093 Line Tracer EN
2 Pages
-
MI 3109 EurotestPV Lite EN
2 Pages
-
MI 3108 EurotestPV EN
2 Pages
-
MI 3125 BT EurotestCOMBO EN
2 Pages
-
MI 3125 EurotestCOMBO EN
2 Pages
-
MI 3100 SE EurotestEASI EN
2 Pages
-
MI 3102 BT EurotestXE EN
2 Pages
-
MI 3143 Euro Z 440 V EN
2 Pages
-
MI 3144 Euro Z 800 V EN
2 Pages
-
MI 3202 GigaOhm 5 kV EN
2 Pages
-
MI 3201 TeraOhm 5 kV Plus EN
2 Pages
-
MI 3311 GammaGT EN
2 Pages
-
MI 3309 BT DeltaGT EN
2 Pages
-
MI 3242 MicroOhm 2A EN
2 Pages
-
MI 3250 MicroOhm 10A EN
2 Pages
-
MI 3252 MicroOhm 100A EN
2 Pages
-
MI 3281 WR Analyser EN
2 Pages
-
MI 2891 Power Simulator EN
2 Pages
-
MI 2883 Energy Master EN
4 Pages
-
MI 2885 Master Q4 EN
4 Pages
-
MI 2884 Energy Master XA EN
4 Pages
-
MI 2892 Power Master EN
4 Pages
-
MI 2893 Power Master XT EN
4 Pages
-
MI 3205 TeraOhmXA 5kV EN
2 Pages
-
MI 3210 TeraOhm XA 10kV EN
2 Pages
-
Metrel application catalogue
28 Pages
-
MI 3155 EurotestXD EN
4 Pages
-
MI 3209 TeraOhmLT 10kV EN
2 Pages
-
MI 3102 BT EurotestXE
2 Pages
-
MD 9930 Thermal camera EN
2 Pages
-
MI 3280 DT Analyser EN
2 Pages
-
MI 3290 Earth Analyser EN
4 Pages