Main Features: • Supports all live tests on LV-electrical circuits: - Loop impedance / prospective fault current - Line impedance / prospective short-circuit current • Built- in fuse characteristics for quick evaluation of measuring results • RCD tests (trip out time, contact voltage, ramp test, Autotest) • Testing on 1- and 3-phase systems • Phase sequence test • Metal test button for touch voltage detection • High accuracy non tripping loop test for RCD protected circuits • Pre-programmed limits • PASS/FAIL evaluation of measurement result • Bright GREEN/RED indicators provides visual evaluation of results • Suited for testing on CAT IV installations • Magnetic holder allowes hands-free operation • Built-in battery charger • Two level memory structure for saving of test results and parameters • Basic downloading with EuroLink PRO PC SW package • Compatible with EuroLink PRO Plus PC SW package • USB and RS232 ports • Robust and ergonomic design Professional solution for smart operator • Verification, maintenance and periodic testing of electrical installations • Evaluation of protective measures in LV-installations (fuse size, RCD operation) • Troubleshooting on live installations • Testing on CAT IV installations (distribution side of installations, LV-substations, industrial plants etc). Instrument: IEC/EN 60364 VDE 100 BS 7671 17th edition CEI 64.8 Applications: IEC/EN 61557 Parts 1,3,6,7,10 IEC/EN 61010-1 IEC/EN 61326 Magnetic holder for hands free operation
Open the catalog to page 1Technical specifications RCD testing Nominal residual current (A, AC) 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000 mA Test current shape Sine-wave (AC), pulsed (A) RCD type G (non-delayed), S (time-delayed) Test current starting polarity 0 ° or 180 ° Voltage range 50 V ÷ 264 V (45 Hz ÷ 65 Hz) Complete measuring range corresponds to EN 61557 requirements. Ordering information Standard set Contact voltage Measuring range (V) 0.0 ÷ 19.9 20.0 ÷ 99.9 Test current max. 0.5xI∆N : Resolution (V) Accuracy 0.1 (-0 % / +15 %) of reading ± 10 digits 0.1 (-0 % / +15 %) of reading Limit contact voltage: 25 V,...
Open the catalog to page 24 Pages
6 Pages
1 Page
2 Pages
2 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
8 Pages
8 Pages
8 Pages
8 Pages
56 Pages
2 Pages
2 Pages
64 Pages
72 Pages
272 Pages
1 Page
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
28 Pages
4 Pages
2 Pages