mode to enable ease of testing for all operator levels. The MI 3110 EurotestIM is a perfect tool for testing permanent Integrated or mobile IT Earthing Systems with Low Voltage Electrical Installation’s Power Supply from Generator or Transformer. Designed for testing Safety of Integrated IT Earthing System with LV Power Generator or Transformer! One single AUTO SEQUENCE ® with programmable limits and sub-tests ensuring Safety on all PASS barrier parameters. APPLICATIONS: • Safety and functionality on IT installations in industry, in hospitals; • Marines and ships; • Mines, other special locations; • Connection of portable power generators; • Construction sites and Road maintenance; • Fire fighting mobile equipment, generators and pumps; • Military vehicles and generators; • SAT and radio / TV broadcasting mobile equipment; • Police vehicles and generators; • afety and functionality on IT installations on the airports, concert halls, fair locations with generators; S • Adjustment and calibrations of IMD devices. STANDARDS: Safety • IEC/EN 61010 -1; EMC IEC/EN 61326 The WORLDS first instrument designed with a Safety evaluation with minimization of Human Error Factor! KEY FEATURES: • IT System recognizing, Voltage Range and Voltage Balance, • ISFL Single Fault Leakage current from Phase 1 and Phase 2 to PE, • Fuse Trip-out Ability Evaluation, Line Impedance and Ipsc Prospective Short Circuit Current, • IMD Insulation / ELM Earth Leakage / RCM Residual Current Monitor Devices Control, • Alarm Trigger or Trip-Out Check and Adjust. DISPLAYED RESULTS AUTO SEQUENCE ® “Functional Safety of Electrical / Electronic / Programmable Electronic Safety related Systems” EN 61508 defining the human error as “human action or inaction that can produce an unintended result”. Measurements • IEC/EN 61557 • Parts 1 to 7 and 10: Equipment for testing, measuring and monitoring of protective measures. • Part 8: Insulation monitoring devices for IT systems • Part 9: Equipment for insulation fault location for IT systems Functionality • IEC/EN 60364 - 4 - 41/42/43, Protection for safety • IEC/EN 60364-6, Verification, testing and reporting • IEC/EN 60364-7, Requirements for special installations or locations • IEC / EN 60364-7-717, Mobile and transportable units • IEC 60364-7-710, Medical locations and associated areas • IEC 61892-6, Mobile and fixed offshore units - Electrical installations, Installation • IEC 60364-7-711, Electrical installations in exhibitions, shows, stands, and fun fairs • IEC 60364-7-708, Electrical installations in marinas and pleasure crafts. Due to unique single and clear AUTO SEQUENCE ® procedure the Human Error Factor in Functional Safety

Open the catalog to page 1
MI 3110 EurotestIM EN - 2

Tehnical specifications Voltage and Measuring range (V) 0 V ÷ 550 V Ordering information: Accuracy ± (2 % of reading + 2 digits) Phase rotation Measuring range (V) 100 V ÷ 550 V Frequency Measuring range (Hz) 10.0 Hz ÷ 500.0 Hz Accuracy ± (0.2 % of reading + 1 digit) Line impedance (EN 61557-3) Measuring range (Ω) 0.00 Ω ÷ 9.99 Ω 10.0 Ω ÷ 99.9 Ω Accuracy ± (5 % of reading + 5 digits) ± (5 % of reading + 5 digits) Measuring range (%) Accuracy Consider accuracy of line impedance measurement(s)* Voltage drop First fault leakage current (ISFL) Measuring range (mA) Resolution (mA) Accuracy ± (5...

Open the catalog to page 2

All METREL catalogs and technical brochures