1. Catalogs
  2. METREL
  3. MD 9880 TRMS thermal multimeter EN

MD 9880 TRMS thermal multimeter EN

MD 9880 TRMS thermal multimeter EN

MD 9880 TRMS thermal multimeter EN

Product catalog summary
Overview: The MD 9880 TRMS thermal multimeter is a comprehensive troubleshooting tool that integrates essential multimeter functions with a thermal viewer. It is designed to quickly identify faults by detecting hot spots and performing electrical measurements. The device is versatile, suitable for various applications including facility maintenance and energy loss analysis.
Measurement Functions:
  • Temperature measurement with camera cursor
  • TRMS DC and AC voltage and current
  • Resistance, frequency, and capacitance measurement
  • Duty cycle and diode test
Key Functions:
  • Thermal view with automatic and manual range
  • Hold and auto-hold modes
  • MIN/MAX values capture
  • Relative and peak capture modes
  • Temperature display in °C, °F, or K
Applications: The device is suitable for troubleshooting electrical installations and equipment, electrical vehicles, mid-level electrical testing, field service, building maintenance, energy loss analysis, and hobby work.
Technical Specifications - Thermal Viewer:
  • IR sensor resolution: 80x80 pxl
  • Temperature range: -20 – 260°C
  • Thermal sensitivity/NETD: 0.1°C @ 30°C / 100 mK
  • Thermal accuracy: ±3°C or ±3%
  • Field of vision: 21° x 21°
  • Spectral range: 8 – 14 µm
  • Frame rate: 50 Hz
  • Focal length: 7.5 mm
  • Spatial resolution: 4.53 mrad
  • Emissivity: 0.01 – 0.99
  • Min focus distance: 0.5m
  • Focus: Fixed
  • Colour palettes: 4
  • IP protection: 40
Technical Specifications - Multimeter:
  • DC voltage: 400.0 mV to 600.0 V, accuracy from ±(0.5% + 5d) to ±(0.8% + 8d)
  • AC TRMS voltage: 4.000 V to 600.0 V, accuracy from ±(1.0% + 5d) to ±(2.5% + 5d)
  • AC + DC TRMS voltage: 4.000 V to 600.0 V, accuracy ±(2.5% + 5d)
  • DC current: 400.0 µA to 10.00 A, accuracy from ±(1.5% + 5d) to ±(2.0% + 8d)
  • AC TRMS current: 400.0 µA to 10.00 A, accuracy from ±(2.0% + 5d) to ±(2.5% + 8d)
  • Resistance/continuity: 400.0 Ω to 40.00 MΩ, accuracy from ±(1.0% + 5d) to ±(2.5% + 10d)
  • Frequency: 40.00 Hz to 10.00 MHz, accuracy from ±(0.2% + 5d) to ±(0.5% + 0d)
  • Capacitance: 40.00 nF to 4000 µF, accuracy from ±(3.0% + 8d) to ±(3.5% + 20d)
  • Duty cycle: 10.0% to 90.0%, accuracy ±(1.2% + 2d)
  • Diode test: Test current <1.5 mA, max open circuit voltage 3.3 V
Ordering Information: The standard set includes the MD 9880 TRMS thermal multimeter, USB cable, carrying case, measuring probes, and instruction manual.
Note: Photographs in the catalogue may differ slightly from the actual instruments delivered. Specifications are subject to change without notice.
See more

Catalog excerpts

MD 9880 TRMS thermal multimeter EN-1

Thermal viewer Thermal viewer MD 9880 TRMS thermal multimeter MD 9880 is the ultimate troubleshooting tool. Combining essential multimeter functions with thermal viewer, it allows a service provider to quickly locate a wide array of possible faults. Hot spots can be then simply tested with electrical measurement. Thermal view also expands the usefulness of the instrument to other applications in the facility or vehicle, locating leaks, frictions stress and thermal losses. MEASUREMENT FUNCTIONS: • Temperature with cursor on camera; • TRMS DC and AC voltage; • TRMS DC and AC current; • Resistance; • Frequency; • Capacitance; • Duty cycle; • Diode test. • Thermal view; • Automatic and manual range; • Hold and auto-hold modes; • MIN/MAX values capture; • Relative mode; • Peak capture mode; • Temperature in °C, °F or K. • Troubleshooting electrical installations (switchboards, contacts, busbars, etc.); • Troubleshooting electrical equipment; • Troubleshooting electrical vehicles; • Mid-level electrical testing; • Field service; • Building and facility maintenance, • Energy loss analysis; • Troubleshooting other installations (pipes, carpentry

 Open the catalog to page 1
MD 9880 TRMS thermal multimeter EN-2

TECHNICAL SPECIFICATION - Thermal viewer ORDERING INFORMATION FUNCTION IR sensor resolution Temperature range Thermal sensitivity/NETD Thermal accuracy Spectral range Frame rate Focal length Spatial resolution Colour palettes Standard set (MD 9880) • MD 9880 TRMS thermal multimeter • USB cable • Carrying case • Measuring probes • Instruction manual TECHNICAL SPECIFICATION - Multimeter FUNCTION Duty cycle Diode test Test current <1.5 mA. max open circuit voltage 3.3 V METREL D.D. Measuring and Regulation Equipment Manufacturer Ljubljanska 77, SI-1354 Horjul, Slovenia T +386 (0)1 75 58 200, F +386...

 Open the catalog to page 2

All METREL catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.